CONFIGURING SERIAL PORTS

Perform the following steps to configure serial ports on a VAU:

1.Click the VAU in the directory tree and select the Serial Ports tab.

2.Highlight a COM port and click Add to activate it.

3.Highlight the COM port in the assigned ports list.

4.Enter serial input information on the following six tabs:

General: Contains required information (refer to Figure 3):

Figure 3. Serial Ports Tab Within General Tab

Interface Type: Options include Monitor, Card Reader, or PTZ.

PTZ Type: The make and model of the PTZ camera connected to the selected port (if PTZ is selected for the Interface Type). Select the type from the drop-down arrow; only one PTZ type can be selected per COM port. To update the drop-down arrow, click Get Types every time you want to configure the PTZ type.

NOTE: For IP PTZ cameras, the PTZ Type is configured on the PTZ tab. Refer to Adding and Configuring Cameras on page 17 for details.

Maximum Line Size: The maximum size of a string coming from the alarm panel. A string longer than this many characters usually indicates an error.

End of Line Characters (First, Second, and Third): A character, such as a carriage return, that indicates a line is complete.

Description: A description of the COM port.

Active: Activates the COM port.

12

C3663M-B (11/09)

Image 12
Contents DS NVR and DS NVs System Software Page Contents Client Startup Options Adding and Deleting Systems List of Illustrations C3663M-B 11/09 Installing the Windows Operating System IntroductionDS NVS Software Installation SERVER/VAU Software InstallationDigital Sentry CLIENT/ADMIN Software TCP/IP AddressesDsadmin Overview Dsadmin Directory TreeAdding and Configuring Servers Adding and Configuring a VAUConfiguring Serial Ports Configuring Storage Locations Port Settings Tab for Serial Input DevicesConfiguring IP Cameras IP Cameras Tab with List of Connected IP CamerasNetwork Storage Video Storage Options Adding and Configuring Cameras GeneralMotion C3663M-B 11/09 On Screen Display TIME-LAPSE Storage Motion Storage PTZ Tab for Configuring PTZ Cameras, Presets, and Tours PTZUser Administration Setting UP Account ManagementCreating Users Admin account properties Assigning PermissionsAvailable Permissions Assigning Camera Permissions User Details Window for System Administration Managing Users Across Multiple SystemsCamera Groups Adding and Configuring Zones Alarm InformationConfiguring Zones Digital Inputs Tab for Assigning Input Points to ZonesC3663M-B 11/09 Configuration Parameters Cameras DirectoryThrottle Exempt Addresses Email Notification Digital Sentry Client Software Running Digital SentryVideo Pane Configuration Recording Mode IndicatorsQuick Review Zooming Into VideoDigital PTZ Creating Local GroupsCamera Sequencing Copying Local Configuration Information to Other Computers Video Controls TABManual Recording Cameras TAB PRINT/EXPORT TABImage Details TAB Exporting a Video ClipEvent History Searching for Logged EventsPlaying Back a Logged Event Recorded Video Searching for Recorded VideoPlaying Back Recorded Video Search TAB Smart SearchClient Manager Changing Passwords Viewing the Message LOGViewing Reports Client Startup OptionsAdding and Deleting Systems Viewing Messages Alarm Assessment Playing Back Current AlarmsAcknowledging Alarms Example of Window with Record Event and Live VideoPTZ Control PTZ Control TabC3663M-B 11/09 Product Warranty and Return Information