Pelco C3662M Repairing and Rebuilding a Digital Sentry Database, Testing a Network Connection

Page 48

REPAIRING AND REBUILDING A DIGITAL SENTRY DATABASE

REPAIRING A RESTORED DATABASE

If you want to maintain video that was recorded since the last backup, complete the following steps:

1.Stop all Digital Sentry services on the server, VAUs, and network storage devices.

2.From the Digital Sentry Server/VAU CD, copy REBUILD.EXE from the UTIL directory to the C:\DigitalSentry directory on the server.

3.If you have any video files saved on distributed VAUs (that is, if the files have not been copied to the server yet), copy REBUILD.EXE from the UTIL directory to the C:\DigitalSentry directory on each VAU.

4.On the server and each VAU, run Command Prompt from Start>Programs>Accessories.

5.Type cd digitalsentry in the Command Prompt window.

6.Press Enter and then type rebuild -go.

7.Press Enter to start the repair process. This process can be lengthy, especially if a large amount of time has elapsed since the backup was created.

A log file named REBUILD.LOG is created in the C:\DigitalSentry directory. Examine the log file for information about the repair procedure.

You may now restart the Digital Sentry services and resume normal operation of the system.

REBUILDING USING -FIXLOCAL

The -fixlocal command should be run only on the computer where the VideoServer service is installed. It queries the database for all local video file records and verifies that the files exist and are the same size. If a file is not found, the corresponding entry is removed from the database. If the program cannot access the drive the video file record points to, the video file record is ignored. If the video server is not configured to copy to a remote location, the -fixlocal command can be run while the VideoServer service is running.

TESTING A NETWORK CONNECTION

These steps allow you to test whether the network connection of computer you are using, or any other computer on the network, is functional.

1.From the Start menu, go to Programs>Accessories>Command Prompt.

2.Type ping 192.168.0.1 (substitute the example IP address with the IP address of the computer whose network connection you are checking) and press Enter.

The following message appears:

Pinging 192.168.0.1 with 32 bytes of data:

You can also ping using a computer name. For example, to ping a Digital Sentry server, you might type ping dsserver.

3.If the network connection is functional, the following message appears: Reply from 192.168.0.1

Reply from 192.168.0.1 Reply from 192.168.0.1 Reply from 192.168.0.1

Even if you ping a computer name, the correct IP address appears if the ping is successful.

If the network connection fails, make sure that the computer you are using can access other computers on the network by repeating these steps using an IP address that is known to be functional. If this works, verify that the original computer whose connection you are testing is properly cabled and that a valid, unused IP address has been entered correctly.

If pinging IP addresses works but pinging names does not, consult your network administrator for alternative network connection procedures.

C3662M (6/08)

47

Image 48
Contents P O R TA N T N O T E Integral Digital Sentry Page Contents C3662M 6/08 List of Illustrations List of Tables Important Safety Instructions Regulatory Notices Video Quality CautionIntroduction Typical SystemsTypical DS Enterprise Distributed System Component Installation DS Enterprise Savr InstallationDS Xpress with XMUX2 Installation Rear Panel of DS Enterprise SavrRear Panel of DS XPress with XMUX2 DS Xpress with Internal Camera Inputs Installation OutputRear Panel of DS XPress with Internal Camera Inputs DS Desktop Installation Rear Panel of 9- and 16-Input DS DesktopDS 1000 Installation Rear Panel of 4-Input DS DesktopRear Panel of DS DS Realvue Xpress Installation Rear Panel of DS RealVue XPressDS Realvue Desktop Installation DS RealVue XPress Audio ConnectorDS RealVue Desktop Alarm Bracket DS Realvue RAID Installation Rear Panel of DS RealVue RAIDXIO Installation XIO Cable DS NVR Installation Rear Panel of DS NVRDMS Installation VAU InstallationRear Panel of VAU XMUX2 Installation Rear Panel of XMUX2-16PTZ Installation DS Enterprise SAVR/DS XPress/VAU PTZ ConnectionsDS Enterprise Distributed System Installation C3662M 6/08 Software Installation Digital Sentry CLIENT/ADMIN SoftwareDigital Sentry SERVER/VAU Software Changing Passwords Procedural InstructionsChanging a Computer Name Changing AN IP AddressChanging the Startup Mode of a Service Starting and Stopping ServicesChanging the Time Zone Configuring and Testing Odbc Connectivity System and Display Requirements for Client ComputersRules for Caching on Digital Sentry Client Computers Renaming DS Components Renaming a DS ServerRenaming a VAU Reconfiguring Dsadmin After AN IP Address Change Changing the SA PasswordConfiguring and Verifying Network Storage Connecting a Serial Input Device to a DS System Flashguard and the Watchdog Service FlashguardtestRelay Output Characteristics RAID IP AddressesIsolating Storage Units on a Private Network Subnet maskUsing the Fltime Utility Using Xpress WinviewUsing Integral License KEY Utility Using Realvue Diagnostic ToolNetwork Health Monitoring Hard DrivesUsing Digital Sentry Backup Manager Backing UP the DatabaseRestoring Archived Data Repairing and Rebuilding a Digital Sentry Database Testing a Network ConnectionRepairing a Restored Database Rebuilding Using -FIXLOCALDigital Sentry Network Speed Simulation Checking for Video FilesRunning a Recovery After RecoveryOption #1 Option #2Recovering Video Files Without a Database Backup Removing References to Local Files on Failed Hard DrivesSpecifications DS RealVue Desktop VideoSpecifications DS RealVue RAID Specifications DS RealVue XPress Specifications DS IP CIFSpecifications DS XPress XMUX-2Specifications DS Desktop Specifications DS Enterprise Specifications DS NVR Product Warranty and Return Information ISO9001
Related manuals
Manual 4 pages 12.31 Kb

C3662M specifications

The Pelco C3662M is a state-of-the-art camera designed for robust surveillance and exceptional performance in various environments. Built for security applications, this camera features advanced imaging technology that ensures reliable monitoring and high-quality video capture.

One of the main features of the C3662M is its high-resolution image sensor. This sensor captures clear and crisp images, even in low-light conditions. With a resolution of 2 megapixels, the camera delivers detailed footage that can be crucial for identification purposes. The camera is capable of generating high-definition video streams, providing security operators with the clarity they need to assess any situation effectively.

The C3662M also incorporates advanced technology such as Wide Dynamic Range (WDR), which allows it to perform exceptionally well in scenes with contrasting lighting. This feature ensures that both the bright and dark areas of a scene are captured with excellent detail, making the camera particularly useful in environments like parking lots or entryways where lighting conditions can vary greatly.

Another critical characteristic of the C3662M is its low-light performance. Equipped with infrared (IR) capabilities, the camera can operate effectively in complete darkness, making it an ideal choice for 24/7 surveillance. The IR illumination allows the camera to capture clear images even when there is no visible light.

The C3662M is also designed for versatility in its deployment. It supports various mounting options and configurations, enabling users to install the camera in various locations, from indoor environments to outdoor settings. The rugged construction of the camera ensures it can withstand adverse weather conditions, making it suitable for use in challenging environments.

In terms of connectivity, the C3662M is compatible with various video management system solutions. It can easily integrate into existing security infrastructures, allowing for seamless operation and monitoring.

With its combination of high-resolution imaging, advanced WDR technology, and versatile installation options, the Pelco C3662M stands out as a premium choice for security applications. This camera addresses the needs of modern surveillance with reliability, ensuring that users can maintain peace of mind through effective monitoring capabilities.