Slant/Fin VHS-120, VHS-150, VHS-90 user service Operating Instructions, To turn off gas to appliance

Page 7

VICTORY II VHS MODELS

C. DO NOT use this appliance if any part has been underwater. Immediately call a qualified service tech- nician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater.

Figure 9.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information on page 6.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot

by hand.

5. Turn gas control knob clockwise to “OFF”. DO NOT force.

6.Wait five (5) minutes (longer for propane) to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on page 6. If you don’t smell gas, go to next step.

7.Turn gas control knob counterclockwise to “ON”.

8.Turn on all electric power to the appliance.

9.Set thermostat to desired setting.

10.If appliance will not operate, follow the instructions

“To Turn Off Gas To Appliance” and call your service or gas supplier.

Figure 10.

To turn off gas to appliance

1.Set thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed.

3.Turn gas control knob clockwise to “OFF”.

DO NOT force.

Your gas boiler must be installed and serviced by a qualified service agency or gas supplier. The lack of proper service can result in a dangerous condition.

7

Image 7
Contents User’s Information Manual For Your SafetyVictory II VHS Models Lighting InstructionsUser Inspection InspectionVenting system inspection Annual Service Technician Inspection Flue passage cleaning Annual Service Technician Inspection and CleaningSafety Information Flame ROLL-OUT Safety SHUT-OFF SwitchFor Your Safety Read Before Operating To turn off gas to appliance Operating InstructionsSLANT/FIN CORPORATION, Greenvale, N.Y Phone 516

VHS-90, VHS-120, VHS-150 specifications

Slant/Fin is a renowned manufacturer in the heating industry, known for producing high-quality hydronic heating solutions. Among their notable offerings are the VHS series of gas-fired hot water boilers, which include the VHS-120, VHS-90, and VHS-150 models. These boilers are characterized by their advanced design and technology that focuses on efficiency, reliability, and user convenience.

The VHS-120, VHS-90, and VHS-150 are designed for residential and light commercial applications, making them versatile choices for various settings. Each model features a stainless steel heat exchanger that enhances durability and efficiency. The stainless steel construction allows for superior heat transfer, contributing to more effective water heating and lower operational costs.

One of the standout technologies in the VHS series is its modulating operation. This feature allows the boiler to adjust its output based on the heating demand, resulting in significant energy savings. With the ability to modulate, these boilers operate quietly and efficiently, only using the energy necessary to meet your specific heating needs. This is particularly beneficial in climates with fluctuating temperatures, as the system can provide consistent comfort without overspending on fuel.

Safety is also paramount in the design of the VHS series. These boilers come equipped with multiple safety features, including a high limit control, flow switch, and a spill switch. These systems work together to ensure that the boiler operates within safe parameters, minimizing the risk of accidents.

Additionally, the VHS series boasts a compact design, making installation easier in tight spaces. The user-friendly control interface allows for straightforward operation and monitoring, empowering users to manage their heating systems effectively. This simplicity extends to maintenance as well; the models are designed for easy access to critical components, making routine checks and servicing hassle-free.

In terms of performance, the VHS-120, VHS-90, and VHS-150 offer a range of heating capacities, enabling them to cater to various building sizes and needs. Their efficiency ratings comply with modern standards, making them environmentally friendly options for homes and businesses looking to reduce their carbon footprint.

In conclusion, the Slant/Fin VHS series — VHS-120, VHS-90, and VHS-150 — represents a blend of innovation and reliability. With their advanced heating technology, safety features, and ease of use, they stand out as excellent options for anyone in need of an efficient and dependable heating solution.