SAFETY WARNING:
KEEP BOILER AREA CLEAR AND FREE FROM COM- BUSTIBLE MATERIALS, GASOLINE AND OTHER FLAM- MABLE VAPORS AND LIQUIDS. FAILURE TO ADHERE TO ABOVE SAFETY WARNING, MAY RESULT IN PERSONAL INJURY OR DEATH AND PROPERTY DAMAGE.
CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE
Ratings and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Installation Requirements:
Boiler Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Chimney Requirements . . . . . . . . . . . . . . . . . . . . . . . . . .3 Air Supply and Venting . . . . . . . . . . . . . . . . . . . . . . . . . .3,4 Controls and Accessories . . . . . . . . . . . . . . . . . . . . . . . . .5 Piping for Water Units . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Installing Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Oil Supply Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Wiring the Boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Vent Piping and Draft Regulator . . . . . . . . . . . . . . . . . . . .5
Operating Instructions:
Precautions Before Starting . . . . . . . . . . . . . . . . . . . . . . .7
Care and Maintenance:
Extended Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Freezing Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Oil Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 General Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Burner Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11,12
IMPORTANT: The installation of this equipment must con- form to the requirements of the authority having jurisdiction or, in the absence of such requirements, to the Installation of Oil Burning Equipment, ANSI/NFPA 31, latest edition, and to the National Electrical Code ANSI/NFPA 70, latest edition. The installation must also conform to the additional require- ments in this Slant/Fin Instruction Manual. Where there is any difference, the more stringent requirement shall govern.
In addition, where required by the authority having jurisdiction, the installation must conform to American Society of Mechanical Engineers Safety Code for Controls and Safety Devices for Automatically Fired Boilers, No.
THIS MANUAL MUST BE LEFT WITH OWNER AND
SHOULD BE HUNG ON OR ADJACENT TO THE BOILER
FOR REFERENCE.
IMPORTANT: This boiler must be installed, serviced and repaired by a trained, experienced, service technician, licensed for the installation and servicing of oil burning hot water heating system equipment or otherwise qualified by the authorities having jurisdiction over the installation.
Printed in U.S.A.305 | Publication No. |
Part No. | Revision C |