Slant/Fin XL-2000 dimensions No. †, Hago

Page 13

XL-2000

 

 

 

 

 

 

 

 

 

 

 

13

 

BURNER DATA - RIELLO BURNERS FOR PACKAGED BOILERS ONLY

 

 

 

 

 

 

(RIELLO R-40 SERIES W/SHORT TUBE)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SLANT/FIN

 

FIRING

 

 

NOZZLES

 

 

OIL PUMP

APPROX.

APPROX.

 

 

RIELLO

 

 

 

 

 

 

AIR

 

BOILER

BURNER

OIL PUMP

 

 

 

 

 

PRESSURE

HEAD

 

 

 

 

 

 

 

MODEL

BURNER

P/N SINGLE

STAGES

RATE

SIZE

 

ANGLE

NOZZLE

 

SETTING

SETTING

SHUTTER

 

MODEL

GPH

 

 

SETTING

 

 

 

STAGE

 

 

(GPH)

 

& TYPE

MFR.

 

(PSIG)

NO. †

NO. †

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XL-20

R-40 F-3

48-0242-100

 

1

0.65

0.5

 

70˚SS

HAGO

170

1

3-1/2

 

 

 

 

 

 

80˚ES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XL-30

R-40 F-5

48-0243-100

 

1

1

0.85

 

70˚ES

HAGO

140

1

2.6

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1.15

0.85

 

70˚ES

HAGO

185

1

3.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XL-40

R-40 F-5

48-0244-100

 

1

1.35

1.2

 

80˚B

DELAVAN

130

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1.5

1.2

 

80˚B

DELAVAN

160

4

4.75

 

 

 

 

 

 

 

XL-50

R-40 F-10

48-0245-100

 

1

1.8

1.5

 

60˚B

DELAVAN

145

1

3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air shutter and head settings shown are approximate ONLY. See START-UP page 7 NOTE: For proper insertion into combustion chamber see figure 8

Figure 7A. Riello 40 Series

Model F-3 & F-5

Electrode Setting

Figure 7B. Riello 40 Series

Model F-10

Electrode Setting

Figure 8

For proper insertion into combustion chamber

Image 13
Contents XL-2000 XL-2000 Ratings and DimensionsMinimum Clearance Chimney CONNECTOR-18AIR Supply and Ventilation see Nfpa 31, latest edi- tion From OUTDOORS. see NoneRequires AIR from OUT DOORS. see ActionXL-2000 Circulating System Installing Controls and Accessories on Boiler UnitsII. AIR Control Systems Wiring the Boiler Installing the BurnerPrecautions Before Starting OIL Burner Domestic HOT WaterCare and Maintenance Cleaning and Filling a NEW Water BoilerDo not USE Ethylene Glycol Because IT is Toxic IV. General MaintenanceIII. OIL Burner XL-2000 Delavan Burner DATA-CARLIN Burners for Packaged Boilers onlyAFG Burner DATA-BECKETT Burners for Packaged Boilers onlyHago NO. †Turbulator Settings Riello 40 Series Turbulator SettingSetting the AIR Adjustment Plate Burner Data RielloSLANT/FIN CORPORATION, Greenvale, N.Y Phone 516