Slant/Fin Oil-fired Boiler dimensions Intrepid

Page 2

2

INTREPID

Standard working pressure 30 psi water, 15 psi steam.

All boilers hydrostatically tested — A.S.M.E.

*For forced hot water heating systems where the boiler and all piping are located within the area to be heated, the boiler may be selected on the basis of gross D.O.E. capacity output. The net I=B=R output ratings shown are based on an allowance for piping and pickup of 1.15 (water) or 1.33 (steam). D.O.E. capacity gross output is divided by the allowance to obtain net rating. The manufacturer should be consulted before selecting a boiler for unusual piping and pickup requirements such as intermittent system operation,

extensive piping, etc.

Ratings apply to the use of light oil at 140,000 Btu per gallon, and apply only when burner models listed on pages 14-16 of this manual are used, and are properly adjusted to pro- duce 13% CO2.

§ Nominal clay tile liner dimensions.

** Tankless heater rating based on intermittent draw.

Water boiler models TR-30 and larger have two firing rates. The boiler is factory shipped at the lower firing rate. To obtain the higher firing rate, refer to the INTREPID boiler installa- tion instructions for the appropriate field adjustments.

Collar is oblong, will fit 6" diameter nominal connector.‡ I.B.R. gross output

¢ This dimension is from the boiler jacket to the center of the flue outlet.

NOTE: All boilers under 300,000 Btuh input are tested and rated for capacity under the U.S. Department of Energy (D.O.E.) test procedures for boilers.

Image 2
Contents Intrepid Intrepid Minimum Clearance Chimney CONNECTOR-18Boiler Location Chimney RequirementsRequires AIR from OUT Intrepid Piping Installing Controls Accessories on Boiler UnitsCleaning Piping System Piping for Steam BoilersOIL Supply Piping Installing the BurnerWiring the Boiler Vent Piping and Draft Regulator Cleaning and Filling a NEW Water BoilerIII. Safety Check for Control System START-UPCOMBUSTION Test Instruments Must be UsedLOW Water CUT-OFF CHECK-OUT Cleaning and Filling a NEW Steam BoilerBlowing OFF a LOW Pressure Steam Boiler Replacement of Steam Boilers Pressure Control CHECK-OUTIntrepid Intrepid Wiring for Packaged Steam Boiler Steam Boiler Wiring for Riello Burner and McDONELL Intrepid Burner Data Beckett CF-375 Burners for Packaged Boilers only DelevanIntrepid Turbulator Settings Riello 40 Series Burner Data RielloIntrepid Intrepid III. OIL Burner IV. General MaintenanceII. Providing Protection for Freezing Page Page SLANT/FIN CORPORATION, Greenvale, N.Y Phone 516

Oil-fired Boiler specifications

The Slant/Fin Oil-fired Boiler is renowned for its reliable performance and efficiency in residential and commercial heating applications. Designed to deliver optimal heating while minimizing fuel costs, this boiler is an excellent choice for those looking to maximize comfort in their living spaces.

One of the main features of the Slant/Fin Oil-fired Boiler is its robust construction, which ensures longevity and resilience against harsh conditions. Crafted from high-quality materials, the boiler boasts a cast iron heat exchanger that provides superior heat retention and distribution. This construction not only contributes to its durability but also enhances its overall energy efficiency.

A standout characteristic of the Slant/Fin Oil-fired Boiler is its advanced burner technology. The unit incorporates a high-efficiency oil burner that ensures complete combustion of the fuel. This upgrade leads to significant energy savings while producing low emissions, thereby making it an environmentally friendly heating solution. The burner is designed for quiet operation, which adds to the comfort of home environments.

The boiler is equipped with an innovative control system that allows users to easily monitor and adjust settings for optimal performance. This feature aids in maintaining a consistent temperature throughout the home, ensuring comfort during the coldest months. Additionally, the system offers diagnostic capabilities, making it easier to troubleshoot and maintain.

Another key characteristic of the Slant/Fin Oil-fired Boiler is its versatility in installation. The compact design allows for installation in a variety of spaces, including basements, utility rooms, and garages. This adaptability makes it a popular choice for homeowners looking to optimize their heating solutions without compromising on space.

Furthermore, Slant/Fin offers a variety of models within its oil-fired boiler range to cater to diverse heating needs. This range includes different output capacities to accommodate various home sizes. With a focus on user-friendly design, the boilers come with clear instructions and support for installation and maintenance.

In conclusion, the Slant/Fin Oil-fired Boiler stands out for its durability, efficiency, and advanced technologies. Its cast iron construction, high-efficiency oil burner, and innovative control systems combine to create a reliable heating solution. A perfect fit for both residential and commercial applications, this boiler ensures comfort and peace of mind, making it a preferred choice among homeowners seeking quality and performance in their heating systems.