American Standard 7024 Attach Cable Connector, Check Operation of POP-UP, Hotcold

Page 3

6 ATTACH CABLE CONNECTOR

Fig. A.

Fig. B.

Thread CABLE CONNECTOR (1) clockwise

 

 

onto DRAIN BODY CONNECTION (2) and

 

1

hand tighten. Fig. A.

 

 

 

Your new POP-UP DRAIN installation is

 

 

now complete. Fig. B.

 

 

Note: Tailpeice on pop-up drain is 1-1/4” O.D.

 

 

Fig. B.

 

 

 

 

1-1/4” O.D.

 

 

2

7 CHECK OPERATION OF POP-UP

Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes.

Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions.

2

8MAKE WATER SUPPLY AND WASTE CONNECTIONS

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE

PURCHASED SEPARATELY.

Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE

SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).

Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet.

1/2" PIPE

 

1

THREAD

 

 

2

 

COUPLING

 

NUT

FLEXIBLE

 

 

SUPPLIES

 

 

 

 

3

 

 

3/8 O.D.

 

 

BULL-NOSE

 

 

RISERS

 

3/8” COMPRESSION

COMPRESSION

 

CONNECTION

 

NUT

 

 

 

 

FERRULE

HOTCOLD

M968867 Rev. 1 . 1

3

Image 3
Contents Turn off hot and cold water supplies before beginning EverClean FinishEverClean Finish & Speed Connect Drain Install FaucetPOP-UP Knob Install POP-UP DrainInstall Black Gasket Install Gray LocknutHotcold Attach Cable ConnectorCheck Operation of POP-UP Make Water Supply and Waste ConnectionsTo change direction of handle Test Installed FittingService Check Drain ConnectionsTroubleshooting Guide Speed Connect DrainIf you need to remove the Stopper Locked Mode Vandal Proof Unlocked ModeFor Drains that are removed from above Sink For Drains that are removed from below Sink7024