American Standard 7024 Test Installed Fitting, Check Drain Connections, Service

Page 4

9TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER

 

SUPPLIES (2) and check all connections for leaks.

4

Remove AERATOR (3).

1

 

Operate both HANDLES (1) to flush water lines thoroughly.

 

Replace AERATOR (3).

1

 

CHECK DRAIN CONNECTIONS

 

Operate POP-UP KNOB (4) and fill lavatory with water.

 

Check that DRAIN STOPPER (5) makes a good seal

 

and retains water in SINK. If DRAIN STOPPER (5)

 

does not seal properly, please refer to Troubleshooting

3

section in these instructions.

 

Release POP-UP KNOB (4) down and check all drain

 

connections and "P" trap for leaks. Tighten

5

if necessary.

 

WASTE

OUTLET

2

2

10 SERVICE

“P” TRAP

1

To change direction of handle:

2

Turn valve to OFF position

Turn INDEX BUTTON (1) “counter-clockwise” and remove.

Remove HANDLE SCREW (2).

 

Pull off HANDLE (3). Pull off ADAPTER (4).

 

Remove SPRING CLIP (5). Lift STOP WASHER (6),

 

turn 90˚ and replace. Replace SPRING CLIP (5).

 

Replace ADAPTER (4).

 

Install HANDLE (3) in correct position by adjusting

 

male teeth on ADAPTER (4) to female teeth in

 

HANDLE ASSEMBLY (1).

 

Install HANDLE SCREW (2) and tighten. Thread

5

INDEX BUTTON (1) clockwise.

 

3

90˚

 

6

4

11 EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

M968867 Rev. 1 . 1

4

Image 4
Contents EverClean Finish EverClean Finish & Speed Connect DrainInstall Faucet Turn off hot and cold water supplies before beginningInstall POP-UP Drain Install Black GasketInstall Gray Locknut POP-UP KnobAttach Cable Connector Check Operation of POP-UPMake Water Supply and Waste Connections HotcoldTest Installed Fitting ServiceCheck Drain Connections To change direction of handleSpeed Connect Drain Troubleshooting GuideIf you need to remove the Stopper Unlocked Mode Locked Mode Vandal ProofFor Drains that are removed from below Sink For Drains that are removed from above Sink7024