Rinnai Q175CP, Q85SN, Q85SP, Q175SN, Q130SN, Q175SP, Q205SP, Q175CN, Q130SP, Q205SN Boiler display, Good

Page 10

The boiler display

Two boiler displays, “Good or Technical” see below.

Good

or standard read out.

During this reading the display will only show what is necessary. Under normal circumstances the display will give a Good reading. In case of a fault this will be shown with, alternate display of Good, with an E or BL code. See further "Errors, maintenance and warranty" .

Operating instructions Rinnai Q-Series

10

0

1

2

3

4

5

6

7

8

9 A

Technical

The second way is a technical read out. In normal situations the following will be shown:

on the left the status in which the boiler is active

(see bottom of this page);

on the right the supply temperature in °F;

the water pressure in the installation in PSI.

When a message (E or BL code) is necessary this will be shown instead of the technical read out.

To switch over from the Good-state to the Technical read out (and vice versa):

- Press 5 sec. on the STEP-button.

Operation indication

(in the first display position by technical read out)

No heat demand

Fan pre/post purge

Ignition phase

Burner active on central heating

Burner active on DHW

Fan check

Burner off when room thermostat is demanding Pump overrun phase for central heating Pump overrun phase for hot water

Burner off because of to high flow temperature

Automatic de-aeration program (Press no button for 17 min.)

Image 10
Contents User information manual Français voirSubject to technical changes Contents of instructionsUpdating of documentation Designated use Safety and general instructionsHazard definitions Operating instructions Rinnai Q-Series Safety For Your Safety Read Before OperatingChecking the water pressure Areas likely to have contaminantsDescription of the boiler Explanation of the function buttons ON-OFF SwitchPump program button Mode-button Reset-buttonStep-button Boiler display GoodWater pressure in the central heating system Water pressure will be shownReplenishing the central heating system Provided with a filling loopTurning the boiler off Re-setting the central heating systemHoliday period Error, maintenance and warranty Maintenance or changes to the appliance may only Be carried out by a qualified technicianOperating instructions Rinnai Q-Series D e d e m p l o Susceptible de modifications techniques Contenu des instructionsMise à jour de la documentation Utilisation prévue Sécurité et instructions généralesDéfinitions des dangers Remarque Sécurité Pour Votre Sécurité Lisez Avant DE Mettre EN MarcheVérification de la pression d’eau Description de la chaudière Commutateur MARCHE-ARRÊT Explication des boutons de fonctionsAffichage BoutondeprogrammedechauffagecentralBouton de Reset Bouton de modeBouton Step ’affichage de la chaudière TechniquePression d’eau dans le circuit de chauffage central Remplissage du circuit de chauffage central Contactezvotreinstallateursivotreinstallation’estpaséquipéed’unebouclederemplissage Période de vacances Arrêt de la chaudièreRéinitialisation du circuit de chauffage central Erreur, maintenance et garantie RemarqueRemarque 800000022 11/2009