Type of Appliance
Rinnai Model Number
AFUE (at minimum vent length)
AFUE (extended vent of 33 ft [2.2 m] and no elbows)
Gas Rate Input (BTU/hour)
Gas Rate Output (BTU/hour) Minimum Gas Supply Pressure Maximum Gas Supply Pressure Electrical Connection
Gas Connection Burners Ignition System Exhaust System Temperature Settings
Temperature Control
Warm Air Outlet
Warranty
RHFE-750ETRA
Vented gas fireplace heater; Inbuilt only; for residential installation, commercial setting, or manufactured home; not designed for installation in a
77% |
| 84% |
|
80% |
| 85% |
|
Low - 11,000 | High - 29,000 | Low - 11,000 | High - 28,000 |
Low - 8,635 | High - 21,900 | Low - 8,855 | High - 21,840 |
4.3 inch (109 mm) W.C. | 9.8 inch (249 mm) W.C. | ||
10.5 inch (267 mm) W.C. | 13 inch (330 mm) W.C. |
AC 120V, 60 Hz
Flex line: 3/8 inch flare nut; ball valve: 1/2 inch female x 3/8 inch flare Flame burners
Electronic spark ignition
Forced combustion, forced convection
Low (L): minimum combustion; High (H): maximum combustion; 60° - 80° F in 2° increments (16° - 26° C in 1° increments)
Electronic thermistor Bottom front louvers
All parts: 2 years from date of purchase
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
© 2011 Rinnai Corporation | 750ETRA SP | 3/2011 |