Stovax 7051Bl, 7053lG, 7008lG, 7008Bl, 7053Bl, 7051lG manual Ventilation

Page 18

PRE-INSTALLATION CHECKS

3. VENTILATION

3.1This appliance requires ventilation to supply combustion air. Any room containing the appliance must have a permanent air vent opening with a total free area of at least 550mm2 per kW of appliance rated output above 5kW.

3.2Increase air supply provisions where a room contains multiple appliances.

3.3If vents open into adjoining rooms or spaces there must be an air vent of at least the same size direct to the outside.

3.4Permanent air vents should be non-adjustable and positioned where they are unlikely to become blocked.

3.5Site the vents where cold draught is unlikely to cause discomfort. This can be avoided by placing vents near ceilings or close to the appliance, see Diagram opposite.

18

Image 18
Contents Brunel 1A/2CB/3CB Installation Installation InstructionsPRE-INSTALLATION Commissioning Maintenance & ServicingDealer appliance was purchased from Appliance Commissioning ChecklistInstallation Engineer Essential Information Must be completedSerial Number User InstructionsGeneral Points AIR ControlsRecommended Fuels Using the Appliance for the First TimeUse a protective gloved hand to operate. See Diagram Do not touch the paint during the first period of useWood Lighting the fireSolid fuel PR7225aBurning Wood Running The applianceAir Inlets Log Guard AR2147 Close the door Burning Solid fuelBurning tips OVER-FIRING ASH RemovalOver night burning Chimney fireChimney Sweeping General CleaningCleaning Glass Care of stoveRiddling mechanism jamming Troubleshooting tipsSeasonal use Glass crackingBrunel TECHNICAL SPECIFICATIONStandard features Packing listPR7225 Brunel DimensionsAll dimensions in mm .4mm = ModelMax. Draught = 2.0mm Wg Min. Draught = 1.0mm Wg U.K Site RequirementsFlue or Chimney Flue PlateHearth Dimensions Flue Outlet PositionsWalls next to hearths 150mm Minimum Thickness W PR7227PRE-INSTALLATION Checks FlueAdditional Ventilation Ventilation Top flue pipe installation Installation InstructionsInstalling the Appliance Legal requirementsDo not use a 90˚ elbow to make this connection Rear flue pipe installationRemoval of the LOG Guard Do not use appliance without the log guard in positionFitting and Removal Fitting & Removal of BaffleBrunel 1A only Riddling Mechanism Multi-fuel onlyCommissioning CommissioningGive the copy of the Instructions to the customer Annual Service Fitting a NEW Door Glass ALL Models Fitting and Removal of the FirebricksFitting and Removal of Baffle Fitting a new door sealBrunel 3CB Basic Spare Parts ListBrunel 1A Brunel 2CB Brunel 1APage Service Records Page