INSTALLATION INSTRUCTIONS
PR8009
The Flue must be installed in accordance with manufacturers instructions.
Flue Pipe 915mm (3ft)
Size | Stovax Part No. |
*5" | 4502 |
6" | 4602 |
Self tappping screw at rear
The Flue must be installed in accordance with manufacturers instructions.
Seal Collar with Fire Cement
Self Tapping Screw
|
| Tee |
|
|
|
| Size | Stovax Part No. |
|
|
|
| 5" | 4516 |
|
|
|
| 6" | (4616)* |
|
|
|
Cap
PR7228
Seal flue collar with Fire Cement
PR7230
To chimney connection as detailed in building regulations
600mm min
1000mm max unsupported
To chimney connection as detailed in building regulation
Elbow with access cover
Size Stovax Part No.
5" 4512
6"* 4612
Flue Pipe 915mm (3ft)
Size Stovax Part No.
600mm min
1000mm max unsupported
Elbow with access cover
Size Stovax Part No.
5" 4512
6"* 4612
Flue Pipe 915mm (3ft)
Size Stovax Part No.
5" 4502
6"* 4602
5" 4502
6"* 4602
PR7229
PR7226
1.3Rear flue pipe installation
• Insert a tee into the flue collar
The tee piece is used as cleaning access.
• Lift appliance into position
Take care not to damage the hearth finish.
•Level using adjustable bolts, see picture 1
•Connect tee to the chimney using flue pipe
•Secure with self tapping screw
•Seal the connecting joints
Do not use a 90˚ elbow to make this connection
2.REMOVAL OF THE LOG GUARD
2.1To remove the Log guard:
•Lift Log Guard clear of the supporting brackets
•Rotate to clear the sides of the door opening.
Do not use appliance without the log guard in position.
3.FITTING & REMOVAL OF FIREBRICKS (BRUNEL 1A ONLY)
3.1Remove the firebricks as part of the routine maintenance. This can be carried out without the use of tools.
3.2Allow the appliance to cool fully before removing firebricks.