Manitowoc Ice K00364 installation instructions Check Procedure, Fault Code Definition Solution

Page 3

Differential, Anti-Short Cycle Delay, Temperature Offset, or Sensor Failure Operation

To set or verify the Differential, Anti-Short Cycle Delay, Temperature Offset or Sensor Failure Operation use the following method:

Factory preset temperature control code settings, as follows:

A. Press and hold MENU until the display changes to flashing SP.

B.Press up and down (arrows) repeatedly until the desired function is displayed.

C.Press MENU to display the function’s current value.

D.Press up and down (arrows) until the desired value is displayed.

E.Press MENU to save the new value. The display returns to the sensor temperature.

F.If no setup entry is made for 30 seconds, the control reverts to the temperature display.

Any saved control settings are non-volatile and remain in the control’s memory during power interruptions.

Check Procedure

WARNING

Line voltage is present inside control. Contact with line voltage can cause serious injury or death.

If the control system does not function properly, verify that the control is wired and set up properly. If the problem persists, use the following procedures to determine the cause of the problem

IMPORTANT:

Follow these troubleshooting procedures in the order presented. Do not skip any of the steps in the procedures.

1.Check for proper voltage to the control.

A.Remove the cover by loosening the four cover screws.

B.Use an AC voltmeter to check the voltage between the common and 120V or 240V terminals.

C.The voltage must be between 102 and 132 volts for 120V applications; 177 and 264 volts for 208/230V applications.

D.If the voltage reading is not within the required range, check the power source and input power wires for problems.

2. Fault Codes

If the LCD displays an alarm or fault code (SF or EE):

Fault Code

Definition

Solution

SF flashing

Open temperature

See Step 3. Cycle

alternately with

sensor or sensor wiring

power to reset control.

OP

 

 

 

 

 

SF flashing

Shorted temperature

See Step 3. Cycle

alternately with

sensor or sensor wiring

power to reset control

SH

 

 

 

 

 

EE

Program failure

Reset the control by

 

 

pressing MENU. If

 

 

problem persists,

 

 

replace the control.

 

 

 

3. Check for proper operation.

IMPORTANT:

Perform Steps 1 and 2 before performing these steps: A. Disconnect the load from the output relay

terminals.

B.Reconnect the sensor leads and supply power to the control.

C.Replace the cover.

D.Check the control settings for proper values.

E.Press and hold MENU until SP appears.

F.Press up and down (arrows) to change the set point temperature above and below the sensor temperature until the relay energizes and de- energizes.

G.If the output relay does not perform as indicated, replace the control.

H.If proper operation of the control is verified, reconnect the load.

Image 3
Contents Control Settings Cubers Flake/Nugget/Chiplet Setting Control Set point ValuePositioning the Touchpad Jumpers Manitowoc Ice, Inc Fault Code Definition Solution Check ProcedureSheet 2 of 4 Rev /14/06 View a Installation InstructionsSheet 3 of 4 Rev /14/06 View C Factory Preset Temperature Control Code Settings AS FollowsSheet 4 of 4 Rev /14/06

K00364 specifications

The Manitowoc Ice K00364 is a cutting-edge ice machine designed to meet the demanding needs of commercial kitchens and businesses that require consistent and high-quality ice production. Renowned for its reliability and efficiency, this unit stands out in the competitive market of ice machines, making it an essential investment for foodservice operations.

One of the main features of the Manitowoc Ice K00364 is its advanced ice-making capability. The machine produces gourmet-quality ice cubes that are ideal for a variety of applications, from beverages to food displays. With a production capacity of approximately 600 pounds of ice per day, it’s suited for medium to large-scale operations, ensuring businesses can keep up with their ice requirements during peak hours.

The K00364 incorporates state-of-the-art technology that enhances its performance and energy efficiency. The unit is equipped with an easy-to-use digital control system that allows operators to monitor and manage the ice-making process effortlessly. This system includes diagnostics and alerts for maintenance, ensuring the machine operates at optimal levels and minimizing potential downtime.

One of the defining characteristics of the Manitowoc Ice K00364 is its durable construction. Built with high-quality materials, the machine is designed to endure the rigors of a busy commercial kitchen. Its stainless-steel exterior not only provides a sleek appearance but also ensures resistance to rust and corrosion, promoting longevity and ease of cleaning.

Another technological innovation featured in this unit is its energy-saving capabilities. The Manitowoc Ice K00364 is engineered to consume less water and energy compared to traditional ice machines, making it an eco-friendly option. This energy efficiency not only helps reduce operational costs but also aligns with many businesses' sustainability goals.

The machine's compact design is also noteworthy, as it allows for flexible installation in various kitchen layouts without compromising space. With adjustable legs, it can be leveled on uneven surfaces, enhancing stability and performance.

In summary, the Manitowoc Ice K00364 is an advanced ice machine that combines high production capacity with cutting-edge technology, durability, and energy efficiency. Its features make it an ideal choice for restaurants, bars, and other establishments that prioritize quality and reliability in their ice supply. Investing in the K00364 ensures that businesses can consistently deliver exceptional service while meeting their operational needs.