Universal 150-FASNG owner manual Operating Instructions, Servicing, Model, Fasng

Page 5

 

Model

 

150-FASNG

OPERATING INSTRUCTIONS

SERVICING

PREPARING FOR OPERATION

1.Check the heater for possible shipping damage. If any is found, immediately notify the factory.

2.Follow all of the "Precautions".

3.Install plumbing to a low pressure (1/2 psig maximum) source of natural gas, using a minumum 3/4" ID hose or flexible connector not over 10 ft. (3.05m) in length.

4.Connect the hose to the heater at the 1/2" SAE flare fitting at the regulator inlet.

5.Securely tighten all gas connections.

6.Open the gas cock and check all gas connections with a soap and water solution. DO NOT USE A FLAME.

7.Connect power cord to well-grounded 115V, 60 Hz, 1Ø source of power.

8.When using an extension cord, make certain that it is a 3- wire (grounded) cord of proper wire size.

START

1.Slowly open the gas cock at the natural gas source..

2.Turn toggle switch on heater to the "On" position and the heater will ignite.

STOP

1.Securely close the gas cock at the gas source.

2.Continue to operate heater until all fuel in the hose has burned.

3.Turn toggle switch on the heater to the "Off" position.

RESTARTAFTERSAFETYSHUTDOWN

1.Securely close the gas cock at the natural gas sourace.

2.Wait 5 minutes.

3.Restart following "Start" procedure.

MAINTENANCEANDSTORAGE

1.The heater should be inspected before each use, and at least annually by a qualified person.

A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:

*The flame is contained within the heater.

*The flame is essentially blue with perhaps some yellow tipping.

*There is no strong disagreeable odor, eye burning or other physical discomfort.

*There is no smoke or soot internal or external to the heater.

*There are no unplanned or unexplained shut downs of the heater.

The parts lists and wiring diagram show the heater as it was constructed. Do not use a heater which is different from that shown. For this heater, the regulator must be set to supply 4" water column (W.C) outlet pressure. If there is any uncertainty about the regulator setting, have it checked.

A heater which is not working right must be repaired, but only by a trained, experienced service person. To find the service center closest to you, visit our website at www.scheuco.com.or call (888) 619-7060.

You may also obtain in-warranty or out-of-warranty service by taking the product to your local service center.

In-warranty products will be repaired with no charge for either parts or labor. Please include a brief statement indicating date, place of purchase, the nature of the problem and proof of purchase.

Out-of-warrranty products will be repaired with a charge for parts and labor.

Page -5-

Image 5
Contents Model 150-FASNG TABLE OF CONTENTSRETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE QUESTIONS? MISSING / DAMAGED PARTSWARNINGS Model 150-FASNG HEATER SPECIFICATIONSheadache OPERATING PRECAUTIONSSAFETY PRECAUTIONS Model 150-FASNG ODOR FADE WARNING SERVICING OPERATING INSTRUCTIONSModel 150-FASNG150-FASNG PARTS WIRING CHART MODEL 150-FASNG WIRING DIAGRAMLIMITEDWARRANTY Model 150-FASNG WARRANTYSERVICE CENTERS Store Information where heater was purchased Warranty RegistrationYour Information Your PreferencesATTN MARKETING DEPARTMENT SCHEU PRODUCTS COMPANY, INC8855 BAKER AVENUE RANCHO CUCAMONGA, CA