FLOOR PROTECTION
INSTALLING FIREPLACE ON COMBUSTIBLE FLOOR
If fireplace is installed on a combustible floor, protect the floor area either side of the fireplace opening and in the front with an insulating
8" Min.
Fireplace
| 16" Min. | |
6" Min. Brick | (400 Unit) | |
or Stone | 20" Min. | |
(500 Unit) | ||
from Top | ||
| ||
of Platform |
| |
|
|
Brick or Stone Hearth Extension
52" (400 Models)
66" (500 Models)
Figure 6 - Installing Floor
Protection (Circulating Model)
Note: Do not block the side air vents or air inlet louvers on the lower front of the fireplace with hearth extension.
8" Min.
| 16" Min. | |
6" Min. Brick | (400 Unit) | |
or Stone | 20" Min. | |
(500 Unit) | ||
from Top | ||
| ||
of Platform |
| |
|
|
Hearth Extension Clearances & Width
| 400 Unit | 500 Unit |
On Both Sides | 8" Min. | 8" Min. |
Front of Fireplace | 16" Min. | 20" Min. |
Extension Width | 52" | 66" |
|
|
|
Air Vents — DO NOT BLOCK
Metal Safety Strip Must Be
Use if Unit Is Placed on
Combustible Floor
Platform May Extend Under Hearth Extension if Desired
Fireplace
Platform
(If Necessary)
Air vents and air inlet louvers allow necessary cooling air around the fire- place. Determine the finished height of the hearth extension to be used. Raise the fireplace on a platform, if necessary, to prevent blocking of air openings and lower louvered panel.
Note: No platform is needed if hearth extension does not exceed 1" thick for circulating units or 6½" for radiant units.
Brick or Stone Hearth Extension | Metal Safety Strip |
52" (400 Models) | |
66" (500 Models) | Must Be Use if |
| Unit Is Placed on |
| Combustible Floor |
Figure 6 - Installing Floor Protection (Radiant Model)
61D0008 | 11 |