GLASS DOOR INSTALLATION
This fireplace has been tested and listed for use with optional Model GD36BA, BD36PBA, GD36SSA, GD42BA, BD42PBA, and GD42SSA glass doors. For installation of glass doors, see the instructions provided with the doors.
FAN ACCESSORY
The model 400BWBCA, 400BWBCIA, 500BWBCA, and 500BWBCIA fireplaces may be equipped with a Model FA2A fan accessory. If the fireplace is to be equipped with the FA2A fan at anytime, the junction box assembly must be installed on the fireplace during fireplace installation. See Figures 43 through 45. If junction box is not installed at this time, wall finishing materials must be removed to gain access to the side of the fireplace to install junction box later.
Note: A rectangular switch knockout is provided on the lower right hand face of the fireplace.
Switch
Knock Out
Attach Each Fan with Two
(2)Screws Here
| Firebox | Opening for |
| Fan Installation | |
| Bottom | |
|
| |
Front of |
| Figure 43 - Blower Location |
|
| |
Fireplace |
|
|
Fan
(Faces Back of Fireplace)
Fireplace Bottom
Figure 44 - Blower Location (Side View)
|
| TO FUSE |
M1 | M2 | OR CIRCUIT |
BREAKER | ||
| FAN | CORD SET |
ASSEMBLIES | 120V, 50HA |
GROUND SWITCH
(SPST)
Figure 45 - Wiring Diagram
Junction Box
Cover
61D0008 | 33 |