GLASS DOOR INSTALLATION

GLASS DOOR INSTALLATION

This fireplace has been tested and listed for use with optional Model GD36BA, BD36PBA, GD36SSA, GD42BA, BD42PBA, and GD42SSA glass doors. For installation of glass doors, see the instructions provided with the doors.

FAN ACCESSORY

The model 400BWBCA, 400BWBCIA, 500BWBCA, and 500BWBCIA fireplaces may be equipped with a Model FA2A fan accessory. If the fireplace is to be equipped with the FA2A fan at anytime, the junction box assembly must be installed on the fireplace during fireplace installation. See Figures 43 through 45. If junction box is not installed at this time, wall finishing materials must be removed to gain access to the side of the fireplace to install junction box later.

Note: A rectangular switch knockout is provided on the lower right hand face of the fireplace.

Switch

Knock Out

Attach Each Fan with Two

(2)Screws Here

 

Firebox

Opening for

 

Fan Installation

 

Bottom

 

 

Front of

 

Figure 43 - Blower Location

 

 

Fireplace

 

 

Fan

(Faces Back of Fireplace)

Fireplace Bottom

Figure 44 - Blower Location (Side View)

 

 

TO FUSE

M1

M2

OR CIRCUIT

BREAKER

 

FAN

CORD SET

ASSEMBLIES

120V, 50HA

FAN ACCESSORYGROUND SWITCH

(SPST)

Figure 45 - Wiring Diagram

Junction Box

Cover

61D0008

33

Page 33
Image 33
Martin Fireplaces 400BWBCIA, 400BWBIA Glass Door Installation, Fan Accessory, Blower Location Side View, Wiring Diagram