TRIM AND MANTEL INSTALLATION FOR GAS APPLIANCES

TRIM AND MANTEL INSTALLATION FOR GAS APPLIANCES

Mantel Trim Installation (Unvented Gas Appliances Only)

The fireplace face may be left exposed or trimmed. If trim is installed, fasten it securely to face of fireplace. Trim materials must not extend closer than 3/8" to the vertical edge of fireplace opening if you plan to use glass doors.

1.Install hood on fireplace with mantels 12" from the opening of fireplace. Mantel may be no more than 12" deep. Combustible framing members may be placed across top spacers. See Figure 38.

2.Combustible mantel and/or trim may be installed within shaded area in Figure 39. Use only non- combustible materials below top of spacers and behind front face.

WARNING

Hood (p/n 075629) must be installed when mantel is 12" from fireplace opening.

Note: Glass doors must be removed when using hood.

Note: No

combustible

materials 12" within 12" Note: Glass doors must be removed when using hood. max. Note: No

of opening.of opening.

12"

2¾" Hood

(p/n 075629)

421/2"

 

8"

Shaded

 

Area

 

 

Top Spacers

 

Non-combustible

 

 

Wall Board

11/2"

max.

54"

47"

Figure 38 - Locating Mantel 12" from Opening

Figure 39 - Placement of Combustible

when Using Hood

Mantel and Trim without Hood

Note: These instructions are for acceptable combustible mantel location in GAS APPLIANCES ONLY. See Figures 40 through 41 for acceptable combustible mantel locations for wood burning fireplaces.

61D0008