CHECKLIST OF DO’S AND DON’Ts

DO’S

1.Do check with local building officials to be sure the instal- lation of the fireplace complies with all building codes and requirements. Obtain required building permits. Do plan your installation with safety as you primary consid- eration.

2.Do use only the prescribed material and parts for the installation of the fireplace.

3.Do insulate the exterior walls surrounding the fireplace to prevent excessive heat loss from the fireplace.

4.Do trim the face of the fireplace only with non-combus- tible materials.

5.Do attach the non-combustible face trim material firmly to the face of the fireplace.

6.Do block in or fasten the fireplace to prevent the possibil- ity of the fireplace shifting out of position.

7.Do connect the air circulation blower to a properly grounded and fused electrical circuit.

8.Do enclose the chimney where it passes through living spaces or spaces accessible for storage purposes to pre- vent contact with and possible damage to the chimney.

9.Do install firestop spacers at each ceiling level when the chimney is installed in a multistory building.

10.Do install the proper chimney cap or chimney housing on the chimney to prevent rain and debris from entering the chimney.

11.Do keep all flammable liquids, gases and pressurized containers away form the fireplace.

12.Do check the fireplace for proper adjustment and opera- tion before leaving it unattended for long periods of time.

13.Do inspect and clean the fireplace chimney regularly.

14.Do keep the fire screens closed when the fireplace is left unattended to minimize the danger of sparks popping out of the fireplace.

15.Do use the grate furnished with and for this fireplace.

16.Do start a fire only with paper, kindling or solid composi- tion fire starters specifically designed for starting a fire. The use of liquid fire starter can cause an explosion within the fireplace.

17.Do place all ashes in a metal container with a tight fit- ting lid and place them on a noncombustible surface well away from other combustible materials until they have completely cooled.

18.Do store your fuel supply at a distance equal to or greater than the spacing recommended for combustible materials from the fireplace.

19.Do build fires of moderate intensity in the fireplace for the first three fires to allow materials to adjust and cure before being subjected to the intense heat of a large fire.

WARNING

If not installed, operated and maintained in accordance with the manufacturers instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness and which are known to the state of California to cause cancer, birth defects or other reproductive harm. Also, operation, installation and servicing of this product could expose you to airborne particles of glass wool fibers known to the state of California to cause cancer through inhalation.”