Hunter Fan 53115, 53114, 53116, 53117 operation manual Wiring

Page 10

Wiring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M CEILI

 

 

 

 

 

 

 

 

 

 

 

O

 

N

 

 

 

 

 

 

 

 

 

R

 

 

 

G

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

M F

 

 

 

 

 

green/yellow (grounding)

 

 

 

 

 

 

 

O

A

 

 

 

 

 

 

 

 

 

 

R

 

 

N

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stripe

 

 

 

 

 

 

 

 

 

 

green/yellow stripe

 

 

 

 

 

 

Using an orange wire

 

 

 

 

green/yellow

 

 

 

 

 

 

 

 

 

 

stripe

 

 

 

 

 

 

connector from

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the

 

hardware bag,

 

 

 

 

 

 

 

 

 

 

 

connect the 3 grounding

 

 

 

 

 

 

 

 

 

 

 

wires (green, green/

 

 

 

 

 

 

 

 

 

 

 

yellow stripe, or bare

 

 

 

 

 

 

 

 

 

 

 

copper) coming from the

 

 

 

 

 

 

 

 

 

 

 

ceiling, downrod, and

 

 

 

 

 

 

 

 

 

 

T

hanging bracket.

F

 

 

 

 

 

 

 

 

E

R

 

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

 

 

K

 

 

 

 

 

 

C

 

 

 

 

C

 

 

 

 

 

 

 

E

 

 

A

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ILING

 

 

 

 

 

 

Note: To connect the wires,

 

 

 

RECE

 

 

hold the bare metal leads

 

M

 

 

 

 

IV

 

 

O

 

 

 

 

E

 

 

 

 

 

 

R

together and place a wire

R

 

 

 

 

 

F

 

 

 

 

 

 

connector over them, then twist

 

 

 

 

 

 

 

clockwise until tight.

 

 

 

 

 

 

 

Using the blue wire

 

white(common

 

black(fanout)

blue(lightout)

 

 

 

 

 

 

 

 

connectors from the remote

 

 

 

 

 

 

 

control hardware bag,

 

out)

 

 

 

 

 

connect the white wire

 

 

 

 

 

 

 

 

 

 

 

 

 

from the receiver (marked

 

 

 

 

 

 

 

“common out”) to the white

 

 

 

 

 

 

 

wire from fan. Connect the

 

 

 

 

 

 

 

black wire from the receiver

 

white

 

black

blue

 

(marked “fan out”) to the

 

 

 

 

 

 

 

 

 

 

black wire from the fan.

 

 

 

 

 

 

 

Connect the blue wire from

 

 

 

 

 

 

 

the receiver (marked ”light

 

 

 

 

 

 

 

out”) to the blue wire from

 

 

 

 

 

 

 

the fan. The red wire from

 

 

 

 

 

 

 

the receiver will not be used,

 

 

 

 

 

 

 

it has a pre-installed wire

 

 

 

 

 

 

 

terminator.

 

 

 

 

 

 

 

 

 

F

 

 

A

 

 

R

 

 

 

 

 

OM F

N

 

 

 

 

 

www.HunterFan.com 1.888.830.1326

 

 

M CEILI

 

 

O

N

R

 

 

G

F

 

 

 

 

 

 

 

 

white (grounded)

black (ungrounded)

 

 

Using an orange wire

 

 

 

 

 

 

 

connector from

 

 

 

 

 

 

 

the

hardware bag,

 

 

white

black

 

 

connect the black wire

 

 

 

 

 

 

(neutral

(live in)

 

 

(ungrounded) from the

 

 

 

 

ceiling to the black wire

 

 

in)

 

 

 

from the receiver (marked

 

 

 

 

 

 

 

“live in”). Connect the

 

 

 

 

 

 

 

white wire (grounded)

 

 

 

 

 

 

 

from the ceiling to

 

 

 

 

 

 

 

the white wire from

 

 

 

 

 

 

 

the receiver (marked

 

 

 

 

 

 

 

 

“neutral in” or

F

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

“common in”).

R

 

 

 

 

 

 

 

 

 

E

 

 

 

O

 

 

I

 

 

 

 

 

 

 

V

 

 

 

 

 

 

E

 

 

 

 

 

 

M R EC

 

 

Refer to CAUTION c.1 on pg. 2

Turn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box.

10

M0069-01 • 04/30/13 • © Hunter Fan Company

Image 10
Contents Table of Contents What to Expect with Your Installation Tools Needed Mounting Options Make sure all four 4 bumpers Are still attached Ceiling BracketFor angled ceilings, point Opening toward peak Preparation Downrod Hand Tighten Put the wires and downrod through On top of the fanWiring Canopy HolesBlades Switch Housing Feed the wire plug through the centerConnect the plugs from the upper Light KitScrews found Bag. Align the notches Install a light bulb in each socket ShadeRemote Control Battery Door Phillips Head ScrewLight Chain Switch Operation, Maintenance, & CleaningReverse Safe-Exit Troubleshooting Change battery

53117, 53115, 53116, 53114 specifications

Hunter Fan Company has been a trusted name in ceiling fans for over a century, renowned for their blend of style, performance, and reliability. Among their range, the models 53115, 53116, 53114, and 53117 stand out, showcasing innovations that enhance both aesthetics and functionality in any space.

The Hunter Fan 53115 model exemplifies a classic design with a modern twist. It features a beautifully crafted wooden blade structure, allowing for optimal air circulation while maintaining an elegant appearance. The fan is equipped with a powerful yet whisper-quiet motor, ensuring that it operates silently, making it perfect for bedrooms and workspaces.

Model 53116 takes a bold, industrial approach, with sleek metal accents and a minimalist design. This fan is not just visually appealing but also boasts energy-efficient technology, helping to reduce overall electricity consumption without compromising on performance. Its remote control functionality adds convenience, enabling users to adjust settings from anywhere in the room.

The 53114 version showcases an innovative energy-efficient LED lighting system, providing excellent illumination while consuming less power compared to traditional light bulbs. This model is ideal for living areas where both comfort and ambiance are crucial. Its reversible motor allows for year-round use, offering a cooling breeze in summer and a gentle heat distribution in winter.

Finally, the Hunter Fan 53117 model captures a more contemporary look, featuring a clean design and a variety of finish options to complement any decor. It is equipped with Hunter's patented WhisperWind motor technology, which guarantees both powerful airflow and quiet performance. This model is compatible with smart home systems, enabling users to control their fan via voice commands or mobile apps.

All four models are built with durability and longevity in mind, featuring high-quality materials that stand the test of time. Whether you prefer a traditional look or a modern aesthetic, the Hunter Fan 53115, 53116, 53114, and 53117 have the features and technologies to enhance your living environment, providing comfort and style for years to come.