Lightolier MBS2GHP1FT, MBS2GHP224 Ordering Information, Options/Accessories, Specifications

Page 2

Mini-Beam HP 2' x 2' Recessed Fluorescent MBS2GHP224 or 1FT

Page 2 of 2

Direct/Indirect, Static, 2 Lamp, Linear T5, 24 Watt, 1 Lamp TT5

Model No. MBS2GHP224UNVPG

LER = FP -64.4 IW - 52.8 BF - 1.00 Comparative yearly lighting energy cost per

1000 lumens = $3.73

Report Number: G2005301

Catalog Number: MBS2GHP224UNVPG

Lamps: FP24/835 HO

Luminaire: Mini-Beam HP (High Performance) with 4" wide 150/1 acrylic

lens

Ballast: Triad B224PUNV-D

Report is based on 2000 Lumens per lamp. Efficiency: 85.3%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.3

 

 

1.4

Shielding Angles:

 

 

55

 

 

65

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

22.920

 

22.920

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

92

88

84

82

80

77

79

77

74

02

84

76

70

72

67

63

69

65

61

03

76

67

59

63

57

52

60

55

51

04

69

59

51

55

49

44

53

48

43

05

64

52

44

49

43

38

48

42

37

06

59

47

39

45

38

33

43

37

33

07

54

42

35

40

34

29

39

33

29

08

50

39

31

37

30

26

36

30

26

09

47

35

28

34

28

23

33

27

23

10

44

34

26

31

25

21

30

25

21

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

2866.

3337.

3641.

55

2736.

3276.

3666.

65

2429.

3134.

3629.

75

1926.

3248.

4046.

85

1049.

2673.

3131.

CANDELA DISTRIBUTION0

 

 

 

0.0

45.0

90.0

FLUX

0

1021

1021

1021

 

5

1015

1030

1045

99

15

979

1035

1099

296

25

911

1030

1062

465

35

814

939

949

571

45

687

800

873

613

55

532

637

713

566

65

348

449

520

439

75

169

285

355

286

85

31

79

94

79

90

0

0

0

 

 

 

 

 

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

860

21.5

25.2

00-040

1431

35.8

41.9

00-060

2610

65.2

76.5

00-090

3413

85.3

100.0

90-180

0000

0.0

000.0

00-180

3413

85.3

100.0

Model No. MBS2GHP1FT120SB

LER = FP - 68.5 IW - 39.7 BF - 1.0 Comparative yearly lighting energy cost per

1000 lumens = $3.64

Report Number: G2005303

Catalog Number: MBS2GHP1FT120SB

Lamps: 40W TT5

Luminaire: Mini-Beam HP (High Performance) with 4" wide 150/1 acrylic

lens

Ballast: RCN-1TTP40-SC

Report is based on 3150 Lumens per lamp. Efficiency: 83.3%

CIE Type-Direct-Indirect

 

 

 

 

Plane:

 

 

 

 

0-Deg

 

90-Deg

Spacing Criteria:

 

 

1.2

 

 

1.5

Shielding Angles:

 

 

90

 

 

90

Plane:

 

 

 

 

0-Deg

 

90-Deg

Luminous Length:

 

22.800

 

22.800

COEFFICIENTS OF UTILIZATION –

 

 

ZONAL CAVITY METHOD. EFFECTIVE

 

FLOOR CAVITY REFLECTANCE 0.200

 

RC

 

80

 

 

50

 

 

30

 

RW

70

50

30

50

30

10

50

30

10

01

90

86

82

80

78

75

77

75

73

02

82

74

68

70

65

61

67

63

60

03

74

65

58

61

55

51

59

54

50

04

68

57

50

54

48

43

52

47

42

05

62

51

43

48

42

37

46

41

36

06

57

46

38

43

37

32

42

36

32

07

53

41

34

39

33

28

38

32

28

08

49

38

30

36

30

25

35

29

25

09

46

34

27

33

27

22

32

26

22

10

43

32

25

30

24

20

30

24

20

LUMINANCE DATA IN CANDELA/SQ. METER

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG. 45-DEG. 90-DEG.

45

2162.

2664.

2883.

55

2073.

2603.

2822.

65

1904.

2468.

2786.

75

1566.

2522.

3086.

85

958.

2189.

2736.

CANDELA DISTRIBUTION0

 

0.0

45.0

90.0

FLUX

0

778

778

778

 

5

774

780

788

75

15

745

793

828

223

25

689

777

811

352

35

610

720

754

440

45

513

632

684

476

55

399

501

543

437

65

270

350

395

339

75

136

219

268

220

85

28

64

80

64

90

2

2

2

 

ZONAL LUMEN SUMMARY

ZONE

LUMENS

% LAMP

% FIXT

00-030

650

20.6

24.8

00-040

1090

34.6

41.5

00-060

2002

63.6

76.3

00-090

2625

83.3

100.0

90-180

0000

00.0

000.0

00-180

2625

83.3

100.0

Ordering Information

Explanation of Catalog Number. Example: MBS2GHP224UNVPG

S

2

G

HP

Mini-Beam

Body Style:

 

 

Fixture

Direct/Indirect

S = Static

Width

Recessed

 

 

 

 

 

 

 

 

 

MB

 

Standard Mini-Beam

 

 

 

 

 

M3

 

 

For NYC Code –Local 3 Manufactured

Options/Accessories

Fusing: Internal fast-blow fusing. Suffix: GLR. Internal slow-blow fusing. Suffix: GMF.

Electrical/Wiring Options: Consult factory.

 

 

 

 

 

 

 

 

Voltage:

 

 

Options:

Ceiling Type:

High

Lamp

Lamp Type:

 

 

Fits both

Performance

Quantity:

(By others)

120, 277 or

 

 

Add appropriate

Standard Grid

Prismatic Lens

1 = 1 Lamp FT = Twin Tube T5

UNV=120-277

 

 

suffix to catalog

and

 

 

2 = 2 Lamp 14 = T5 14 Watt

 

 

 

no, ie: (GLR)

Slot Grid

 

 

 

 

24 = T5HO 24 Watt

 

Ballast

Type:

 

 

 

 

 

 

 

(Nominal 24")

1 Lamp Elec. TT5

 

<20THD <10THD

 

 

 

 

 

 

 

 

 

SB *

IB *

 

 

 

 

 

 

 

 

(40 Watt)

 

 

 

 

 

 

 

 

 

 

 

1 Lamp Elec. TT5

 

 

PR *†

 

 

 

 

 

 

 

 

(40 Watt) Program Start

 

 

 

 

 

 

 

 

 

1 Lamp Elec. TT5

 

BE *

BP *†

 

 

 

 

 

 

 

 

(50 Watt) Program Start

 

 

 

 

 

 

 

 

 

1 Lamp Elec. TT5

 

BF *†

 

 

 

 

 

 

 

 

(55 Watt) Program Start

 

 

 

 

 

 

 

 

 

Linear T5 Elec. Program Start –

PG **

*Instant Start Standard

NOTE: For 1 lamp TT5 UNV voltage you must use PR,

BP or BF Ballast Code.

DA = DALI digital addressable dimming

Specifications

Performance: In an installation of 2 lamp 24W luminaires in a room cavity of 1, with reflectance of 80% ceiling, 50% walls, 20% floor, the C.U. shall not be less than .88. To reduce glare the average brightness at 65° shall not exceed 3629 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.8%.

Materials: Housing is die-formed 20 gauge steel.

Finish: Chassis exterior–baked white acrylic enamel. Reflector–baked flat white acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield–white virgin acrylic lens.

Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°.

Labels: I.B.E.W./UL and ULc Listed.

Job Information

Type:

 

 

Lightolier a Genlyte company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710

We reserve the right to change details of design, materials and finish.

© 2006 a Genlyte company

Section 5/Folio M20-28

Image 2
Contents Mounting Methods FeaturesDimensions Ordering Information Options/AccessoriesSpecifications