Samsung AQV12PWCXEUR, AQV12PWAX, AQV09PWCXEUR manual Flow movement changes. It is normal, Connection

Page 21

PROBLEM

SOLUTION

 

 

Error is indicated.

• When an indoor unit indicator blinks, contact the nearest service center.

 

 

Noise is generated.

• Depending on the status of the air conditioner usage, noise can be heard when refrigerant

 

flow movement changes. It is normal.

 

 

Smoke is generated from

• If may not be a fire but it can be a steam generated by the defrost operation from outdoor

the outdoor unit.

heat exchanger during Heat mode in winter.

 

 

Water is dropping from

• Water may be generated because of the temperature difference. It is normal.

the outdoor unit piping

 

connection.

 

 

 

ENGLISH

21

Image 21
Contents Page Contents Important safety symbols and precautions Safety precautionsFollow directions Wall socketFor Using For Cleaning Operation ranges Checking before useChecking the name of the parts Power buttonMain parts DisplayRemote controller buttons Checking the remote controllerBattery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press Button to adjust the temperatureUsing the Turbo function Adjusting the air flow directionPress the Air swing button on the remote controller Vertical air flowPress the button on the remote controller When the air conditioner is on and in cool/heat modeMode Press the Time Up or Time Down button to set the timeSetting the On/Off timer Press the On Timer/Off Timer buttonAdditional options available in On timer mode From the moment you have set the timer Using the Smart Saver functionIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsing the Quiet function Using the Auto Clean functionWhen the air conditioner is turned on Cleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger Opening the panelRemoving the Air filter Cleaning the air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaPeriodical checks Maintaining the air conditionerTroubleshooting Outdoor unit Heat exchanger during Heat mode in winter Flow movement changes. It is normalConnection General information Included Models RemarkAQV09P, AQV12P, AQV18P, AQV24P Installing the unit Choosing the installation locationPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyOutdoor Unit Where sulfide gas existsWhen installing more than 1 outdoor unit When installing 1 outdoor unitSpace Requirements for Outdoor Unit Top view Side viewAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsConnecting the assembly cable Cable specificationConnecting the cable Installation Each wire is labeled with the corresponding terminal numberSmooth the cut edges Cut off the remaining foam insulationPass the pipe through the hole in the wall Cutting or extending the pipe Purging the indoor unitUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flareCorrect Inclined Pipe 50 Pa. The joint must be accessible and serviceableCracked Outer DiameterDrain hose installation Purging the connected pipes Connect a drain hose to the drain plugEnsure that condensation draining is adequate Adding Refrigerant Please fill in with indelible ink  the factory refrigerant charge of the product1975 To check for gas leaks on the outdoor unit Performing the gas leak testsTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesThen place the indoor unit on the installation plate Fixing the indoor unit in placeFixing the outdoor unit in place Final Check and Trial Operation Apply heat to the contraction tube to contract it How to connect your extended power cablesAfter tube contraction work is completed, wrap it with Insulation tape to finishPage Samsung 7267864, € 0.07/min 42 2702-201-24-18 05 133Air Conditioner
Related manuals
Manual 41 pages 49.75 Kb Manual 21 pages 29.77 Kb Manual 41 pages 50.29 Kb Manual 43 pages 23.26 Kb Manual 41 pages 10.61 Kb Manual 39 pages 33.67 Kb Manual 43 pages 50.37 Kb Manual 41 pages 25.73 Kb Manual 41 pages 6.72 Kb Manual 41 pages 27.43 Kb Manual 43 pages 2.11 Kb Manual 41 pages 20.41 Kb

AQV09PSCXEUR, AQV09PWCNEUR, AQV09PWCXEUR, AQV12PWAX, AQV09PSCNEUR specifications

The Samsung AQV12PSCXEUR, AQV12PSCNEUR, AQV09PSCNEUR, and AQV09PSCXEUR are advanced air conditioning models that exemplify Samsung's commitment to energy efficiency and innovative cooling technology. These units are designed for both residential and commercial applications, providing optimal comfort and superior performance in diverse environments.

One of the main features of these models is their inverter technology, which allows for precise control over the cooling output. By adjusting the compressor's speed according to the current temperature, these air conditioners maintain a consistent climate, significantly reducing energy consumption compared to traditional units. This technology not only contributes to lower electricity bills but also enhances the system's lifespan by reducing wear and tear.

Additionally, these units are equipped with a high-performance air filtration system. This system captures dust, allergens, and other particulate matter from the air, ensuring a healthier indoor environment. The filters are designed to be easily removable and washable, promoting convenient maintenance and long-term efficiency.

The design and aesthetics of the Samsung AQV series are another highlight. With a sleek, modern appearance, these air conditioners can seamlessly blend into any room decor. The compact size offers flexibility in installation, allowing users to maximize space without compromising on style.

Noise levels are kept to a minimum thanks to the advanced engineering of these models. Utilizing sound-dampening technology, the AQV series operates quietly, making them suitable for bedrooms, offices, and other noise-sensitive areas.

Another key characteristic of the AQV12PSCXEUR, AQV12PSCNEUR, AQV09PSCNEUR, and AQV09PSCXEUR is their eco-friendly refrigerant. By utilizing R32 refrigerant, these models comply with environmental regulations and contribute to reduced greenhouse gas emissions. This is a significant advantage for environmentally conscious consumers looking to make sustainable choices.

In terms of user experience, these air conditioners feature a user-friendly interface and remote control functionality. This allows users to effortlessly adjust settings, program timers, and switch modes from the comfort of their seat. Additionally, many units in the series can be connected to smart home systems, providing even greater convenience through integration with mobile devices.

In conclusion, the Samsung AQV12PSCXEUR, AQV12PSCNEUR, AQV09PSCNEUR, and AQV09PSCXEUR air conditioners are packed with features designed for efficiency, comfort, and convenience. With their inverter technology, superior filtration systems, quiet operation, modern design, and eco-friendly refrigerants, they stand out as a leading choice for anyone seeking reliable cooling solutions.