Samsung AQV09PSCNEUR manual Space Requirements for Outdoor Unit, When installing 1 outdoor unit

Page 25

Space Requirements for Outdoor Unit

If using a multi system, install as described in the installation manual supplied with the outdoor unit.

When installing 1 outdoor unit

Figure Description

 

 

 

Top view

 

Side view

 

 

 

 

 

Air intake

Air outlet

 

 

Air intake

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

,

Air flow direction.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Unit : mm)

When the air outlet is opposite the

When the air outlet is towards the

When 3 sides of the outdoor unit are

 

wall

 

 

 

wall

 

 

 

 

blocked by the wall

ENGLISH

300 or more

The upper part of the outdoor unit and the air outlet is towards the wall

2000 or more

or more

 

1500

1500 or more

The upper part of the outdoor unit and the air outlet is opposite the wall

500 or more

300 or more

 

300 or more

150 or more

600 or more

When the walls are blocking front and the rear side of the outdoor unit

1500 or 300 or more more

When installing more than 1 outdoor unit

 

(Unit : mm)

When the air outlet is towards the wall

When 3 sides of the outdoor unit are blocked by the wall

1500 or more

300 or more

300 or more

600 or more 600 or more 600 or more

25

Image 25
Contents Page Contents Important safety symbols and precautions Safety precautionsFollow directions Wall socketFor Using For Cleaning Operation ranges Checking before useChecking the name of the parts Power buttonMain parts DisplayRemote controller buttons Checking the remote controllerBattery changing time Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press Button to adjust the temperatureUsing the Turbo function Adjusting the air flow directionPress the Air swing button on the remote controller Vertical air flowPress the button on the remote controller When the air conditioner is on and in cool/heat modeMode Press the Time Up or Time Down button to set the timePress the On Timer/Off Timer button Setting the On/Off timerAdditional options available in On timer mode From the moment you have set the timer Using the Smart Saver functionIf the air conditioner is on If the air conditioner is off Turn off automaticallyUsing the Auto Clean function Using the Quiet functionWhen the air conditioner is turned on Cleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger Opening the panelRemoving the Air filter Cleaning the air filterOpen the panel and put the Air filter out Dry the Air filter in a ventilated areaPeriodical checks Maintaining the air conditionerTroubleshooting Flow movement changes. It is normal Outdoor unit Heat exchanger during Heat mode in winterConnection Included Models Remark General informationAQV09P, AQV12P, AQV18P, AQV24P Installing the unit Choosing the installation locationPower supply line, fuse or circuit breaker  a place where the air filter can be replaced easilyOutdoor Unit Where sulfide gas existsWhen installing more than 1 outdoor unit When installing 1 outdoor unitSpace Requirements for Outdoor Unit Top view Side viewAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsCable specification Connecting the assembly cableConnecting the cable Installation Each wire is labeled with the corresponding terminal numberCut off the remaining foam insulation Smooth the cut edgesPass the pipe through the hole in the wall Cutting or extending the pipe Purging the indoor unitUnscrew the caps at the end of each pipe Put a flare nut slightly into the pipe and modify the flareCorrect Inclined Pipe 50 Pa. The joint must be accessible and serviceableCracked Outer DiameterDrain hose installation Connect a drain hose to the drain plug Purging the connected pipesEnsure that condensation draining is adequate Adding Refrigerant  the factory refrigerant charge of the product Please fill in with indelible ink1975 To check for gas leaks on the outdoor unit Performing the gas leak testsTo check for gas leaks on the indoor unit Leak test with nitrogen before opening valvesFixing the indoor unit in place Then place the indoor unit on the installation plateFixing the outdoor unit in place Final Check and Trial Operation Apply heat to the contraction tube to contract it How to connect your extended power cablesAfter tube contraction work is completed, wrap it with Insulation tape to finishPage Samsung 7267864, € 0.07/min 42 2702-201-24-18 05 133Air Conditioner
Related manuals
Manual 41 pages 49.75 Kb Manual 21 pages 29.77 Kb Manual 41 pages 50.29 Kb Manual 43 pages 23.26 Kb Manual 41 pages 10.61 Kb Manual 39 pages 33.67 Kb Manual 43 pages 50.37 Kb Manual 41 pages 25.73 Kb Manual 41 pages 6.72 Kb Manual 41 pages 27.43 Kb Manual 43 pages 2.11 Kb Manual 41 pages 20.41 Kb

AQV09PSCXEUR, AQV09PWCNEUR, AQV09PWCXEUR, AQV12PWAX, AQV09PSCNEUR specifications

The Samsung AQV12PSCXEUR, AQV12PSCNEUR, AQV09PSCNEUR, and AQV09PSCXEUR are advanced air conditioning models that exemplify Samsung's commitment to energy efficiency and innovative cooling technology. These units are designed for both residential and commercial applications, providing optimal comfort and superior performance in diverse environments.

One of the main features of these models is their inverter technology, which allows for precise control over the cooling output. By adjusting the compressor's speed according to the current temperature, these air conditioners maintain a consistent climate, significantly reducing energy consumption compared to traditional units. This technology not only contributes to lower electricity bills but also enhances the system's lifespan by reducing wear and tear.

Additionally, these units are equipped with a high-performance air filtration system. This system captures dust, allergens, and other particulate matter from the air, ensuring a healthier indoor environment. The filters are designed to be easily removable and washable, promoting convenient maintenance and long-term efficiency.

The design and aesthetics of the Samsung AQV series are another highlight. With a sleek, modern appearance, these air conditioners can seamlessly blend into any room decor. The compact size offers flexibility in installation, allowing users to maximize space without compromising on style.

Noise levels are kept to a minimum thanks to the advanced engineering of these models. Utilizing sound-dampening technology, the AQV series operates quietly, making them suitable for bedrooms, offices, and other noise-sensitive areas.

Another key characteristic of the AQV12PSCXEUR, AQV12PSCNEUR, AQV09PSCNEUR, and AQV09PSCXEUR is their eco-friendly refrigerant. By utilizing R32 refrigerant, these models comply with environmental regulations and contribute to reduced greenhouse gas emissions. This is a significant advantage for environmentally conscious consumers looking to make sustainable choices.

In terms of user experience, these air conditioners feature a user-friendly interface and remote control functionality. This allows users to effortlessly adjust settings, program timers, and switch modes from the comfort of their seat. Additionally, many units in the series can be connected to smart home systems, providing even greater convenience through integration with mobile devices.

In conclusion, the Samsung AQV12PSCXEUR, AQV12PSCNEUR, AQV09PSCNEUR, and AQV09PSCXEUR air conditioners are packed with features designed for efficiency, comfort, and convenience. With their inverter technology, superior filtration systems, quiet operation, modern design, and eco-friendly refrigerants, they stand out as a leading choice for anyone seeking reliable cooling solutions.