| Test instrumentation |
|
| Model name |
|
| Manufacturer |
|
| Serial or Firmware |
|
| Calibration |
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| (No./Ver.) |
|
|
|
| |||
|
|
|
|
|
|
|
|
| Date | |||||
|
|
|
|
|
|
|
|
|
|
|
| |||
| Stopwatch |
| PC90 |
| Time Art |
| TPST003 |
| 1st Apr. 2015 | |||||
|
|
|
|
|
|
|
|
| ||||||
| Power meter |
| WT1806 |
| Yokogawa |
| 30th Mar. 2015 | |||||||
| Power Source | 61605 |
|
| Chroma |
| 7th Oct. 2015 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1.8Measurement method used
-Measurement condition_1) Picture : no input load, 2) Sound : no input load.
-Deactivate all other network ports that are not under test.
-Ensure that the EUT does not perform a main function and wait for 20 minutes, So that the EUT able to go into the networked mode.
-The EUT standby mode power consumption was monitored for a further period of 5 minutes.
The variation in power consumption over this period is 5%, so the maximum reading of NTW standby mode power as measured by the power analyzer≤is recorded as the test result
1.9
2. Off mode
2.1Test result
Test date
Power Consumption (W)
(rounded to the 1st decimal place)
0.0
2.2 Test parameters
parameters |
|
| Actual |
| Limit |
| parameters | Actual | Limit |
|
|
|
|
|
|
|
|
|
|
Ambient temperature ( ) | 26.0 | 23±5 |
| Test voltage (V) | 230 | 230±2.3 | |||
|
|
|
|
|
|
|
|
|
|
Test frequency (Hz) |
| 50 | 50±0.5 |
| Total harmonic distortion | 1.42 | 2 | ||
|
|
|
|
|
|
| (%) |
|
|
|
|
|
|
|
|
|
|
|
|
Crest factor | ℃ | 1.40 | 1.34~1.49 | - | - | - | |||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
2.3 Description of how the appliance mode was selected or programmed Standby mode was selected by turning off by remote server
3