Lightolier Baselyte-BSL2 specifications Ordering Information, Specifications

Page 1

Lighting SystemsBaselyte-BSL2

Page of 8

angled lamp

3 Light T8 Direct/Indirect

Ordering Information

Weight = 3.0 lb/ft





Family

Distribution

 

 

 

 

BSL

 

 

6

 

Lamp Type

No. of Lamps

 

 

 

 

T

 

 

03

 

Housing

CN

Module Length

WiringVoltage

BallastFinish

6 = Direct/

Indirect

T = T8

03 = 3 Light

CN = Cutout w/baffles

04 = 4’

08 = 8’

12 = 12’

1 = 1cct.

1 = 120V

2 = 2cct.

2 = 277V

3= 1cct. w/EC/NL

4= 2cct. w/EC/NL

5= 1cct. w/EM Battery

6= 2cct. w/EM Battery

7= 1cct. w/Dimming

8= 1cct. w/1cct.

Thru wire

9 = 2cct. w/1cct. Thru wire

Note: Please consult wiring section of spec sheets for more wiring options.

E = Standard <20% THD

F = Standard <20% THD w/fusing

G = <10% THD, Instant Start H = <10% THD, Instant Start

w/fusing J = <10% THD,

Program Start K = <10% THD,

Program Start w/fusing

C = Custom Color

W = Standard

White

Specifications

Features

1.Housing: die-formed 20ga. cold rolled steel

2.End Set: die-cast metal with baked powder coat finish

3.Lamping: three T8 lamps

4.Configuration: 4’, 8’ and 12’ module lengths or continuous rows

5.Ballasts: electronic 120V or 277V

Finish

High-quality white powder coat with textured matte finish.

Custom colors available. Consult factory.

Mounting

Aircraft cable gripper is tamper-resistant and provides infinite vertical adjustment capability. Aircraft cable, crimp and cable gripper independently tested to meet stringent safety requirements.

Electrical

All luminaires are factory pre-wired to module ends with quick-wire connectors.

Joints & Intersections

Self-aligning joining system with hands-free pre-joining wire access.

Labels

UL, CSA standards.

Ordering Instructions

Individual Fixtures

1.Determine the number of individual modules required

2.Order one end set per module

3.Order one non-power mount per module

4.Order one power mount per module

Continuous Rows*

1.Determine run length

2.Order the appropriate number and length of modules for complete run

3.Order one end set for each run

4.Order one non-power mount for each module

5.Order one power mount per run

6.Order one joiner per module minus one (e.g. 3 modules requires 2 joiners)

*Note: Some runs may require additional power mounts. Please see the ‘Run Configuration’ table on next page for more details.

Job Information

Type:

Job Name:

Cat. No.:

Lamp(s): Notes:

Lightolier a Genlyte Companywww.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Image 1
Contents Ordering Information SpecificationsOrdering Instructions System Components & Accessories Run ConfigurationPerformance Module Lengths & Mounting DistancesMount Type T-Bar 15/16 On-Grid Mounting OptionsSupension Length Mount Type T-Bar 9/16 On-GridMount Type T-Bar Variable Position Mount Type T-Bar Fixed Position 1/4-20 Threaded RodMount Type Support or Open-Joist Ceiling Cord Types Mount Type Non-Accessible Ceilings concrete, gypsum etcConductor Circuit with Emergency Battery Pack EM Wiring Options 1 CircuitCircuit Type 1 1cct Circuit Center/Outer Switching Type 2 2cct Wiring Options 2 Circuit Center/Outer SwitchingType 4 2cct. w/EC/NL Type K Chloride standard C700AType C 2cct. w/EC/NL Circuit A/B Switching alternate 4’ sections Type B 2cctType D Chloride standard C700A Type O Bodine standard B70A