Lightolier Baselyte-BSL2 specifications Wiring Options 1 Circuit, Circuit Type 1 1cct

Page 6

Lighting SystemsBaselyte-BSL2

Page of 8

Wiring Options: 1 Circuit

1 Circuit

Type 1: 1cct.

Type 8: 1cct. w/1cct. thru wire

Type H: 1cct. w/2cct. thru wire

Type 7: 1cct. w/dimming

3 Light T8 Direct/Indirect



















All lamps wired on one circuit.

1 Circuit with Emergency Circuit/Night Light (EC/NL)

Type 3: 1cct. w/EC/NL





%#.,





%#.,





%#.,

One 4’ section in a one circuit fixture to be wired on a separate thru circuit. Leads for both normal circuit and EC/NL circuit wired to fixture ends. All lamps in EC/NL section to be wired together.

1 Circuit with Emergency Battery Pack (EM)

Type 5: Chloride standard

C700A

Type M: Bodine standard

B70A

Type E: Chloride high performance

C1400

Type P: Bodine high performance

B50











 %-







All lamps wired on one circuit, plus a battery pack is wired to one lamp. A hot lead is connected to the battery pack and would function as a ‘trigger’ wire when connected to a constant hot by installer. Leads for both normal circuit and battery pack are wired to fixture ends.

*Note: Multi-lamp battery packs are also available.

1 Circuit with Emergency Circuit/Night Light and Emergency Battery Pack

Type J: Chloride standard C700A





%#.,





%#., %-





%#.,

One 4’ section in a one circuit fixture to be wired on a separate thru circuit, in addition, a battery pack is wired to one lamp. Installer can connect ‘trigger’ wire to EC hot lead if controlled together or wire separately if controlled independently. Leads for normal circuit, EC/NL and EM wired to fixture ends. All lamps in EC/NL section to be wired together.

*Note: Multi-lamp battery packs are also available.

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Image 6
Contents Specifications Ordering InformationOrdering Instructions Performance Run ConfigurationSystem Components & Accessories Module Lengths & Mounting DistancesSupension Length Mounting OptionsMount Type T-Bar 15/16 On-Grid Mount Type T-Bar 9/16 On-GridMount Type T-Bar Fixed Position 1/4-20 Threaded Rod Mount Type T-Bar Variable PositionMount Type Support or Open-Joist Ceiling Mount Type Non-Accessible Ceilings concrete, gypsum etc Cord TypesConductor Wiring Options 1 Circuit Circuit with Emergency Battery Pack EMCircuit Type 1 1cct Type 4 2cct. w/EC/NL Wiring Options 2 Circuit Center/Outer SwitchingCircuit Center/Outer Switching Type 2 2cct Type K Chloride standard C700AType D Chloride standard C700A Circuit A/B Switching alternate 4’ sections Type B 2cctType C 2cct. w/EC/NL Type O Bodine standard B70A