Lightolier Baselyte-BSL2 Performance, Module Lengths & Mounting Distances, Run Configuration

Page 2

Lighting SystemsBaselyte-BSL2

Page

 

of 8

 

 

 

 

 

 

Performance

 

 

 

 

 

 

Candlepower Curve

Candlepower Summary

 

 

 







 

ZONE

 

CANDLEPOWER

 

 

 

 

 

 

 

 

DEG.

0

22.5

45

67.5

90

 

 

 



 

 

 

 

 

 

 



 

180

1740

1740

1740

1740

1740

 

 

 



 

175

1730

1730

1733

1729

1730

 

 

 



165

1668

1665

1681

1689

1696

 

 

 



155

1554

1555

1597

1616

1631

 

 

 



145

1389

1402

1479

1551

1582

 

 

 

135

1179

1208

1357

1469

1511

 

 

 

 

 

 

 

 

 



125

927

998

1208

1339

1377



 

 



115

647

777

1002

1058

1096

 

 

105

353

525

655

647

676

 

 

 





 

 

95

91

147

213

186

212

 

 

 

 

 

 

 



 

90

7

29

45

53

51



 

 



 

85

23

35

53

58

62



 

 



 

75

52

62

98

96

102

 

 



 

65

98

117

128

152

169

 

 

 







 

55

201

191

194

186

195

 

 

 

 

 

Report No: 2101590

45

329

282

260

256

262

35

452

391

339

316

322

Lamps: F32T8

25

568

508

472

418

412

Lumens per Lamp: 2950

15

663

626

592

558

562

Efficiency: 84.1%

5

720

712

701

681

685

Up: 82.2% Down: 17.8%

0

727

727

727

727

727

Module Lengths & Mounting Distances

@

-ODULE ,ENGTH ,

-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

@

-ODULE ,ENGTH ,-OUNTING $ISTANCE

Note: Shaded area indicates locations of emergency sections (emergency wiring controls all lamps or optional battery pack controls one or two lamps).

3 Light T8 Direct/Indirect

Coefficients of Utilization

 

 

% EFFECTIVE CEILING CAVITY REFLECTANCE

 

 

 

80

 

 

70

 

 

 

50

 

 

 

 

 

% WALL REFLECTANCE

 

 

 

 

50

30

10

50

30

10

 

50

30

10

0

83

83

83

73

73

73

 

55

55

55

1

72

69

66

64

61

59

 

48

46

44

2

63

58

54

56

52

48

 

42

39

37

3

55

50

45

49

44

40

 

37

34

31

4

49

43

38

43

38

34

 

33

29

26

5

43

37

32

38

33

29

 

29

25

22

6

39

32

28

34

29

25

 

26

22

19

7

35

29

24

31

26

22

 

24

20

17

8

31

25

21

28

23

19

 

21

18

15

9

29

23

19

25

20

17

 

19

16

13

10

26

20

17

23

18

15

 

18

14

12

Zonal Lumen Summary

 

ZONE

LUMENS

%BARE LAMP

%LUMINAIRE

0-90

1328.5

15.0

17.8

90-180

6118.5

69.1

82.2

0-180

7447

84.1

100.0

Run Configuration

Run

4’

8’

12’

Joiner

End Set

Mount

Power

Length

Module

Module

Module

Mount*

 

 

 

 

 

 

 

 

 

 

 

4’ run

1

 

 

 

1

1

1

 

 

 

 

 

 

 

 

8’ run

 

1

 

 

1

1

1

 

 

 

 

 

 

 

 

12’ run

 

 

1

 

1

1

1

 

 

 

 

 

 

 

 

16’ run

 

2

 

1

1

2

1

 

 

 

 

 

 

 

 

20’ run

 

1

1

1

1

2

1

 

 

 

 

 

 

 

 

24’ run

 

 

2

1

1

2

1

 

 

 

 

 

 

 

 

28’ run

 

2

1

2

1

3

1

 

 

 

 

 

 

 

 

32’ run

 

1

2

2

1

3

1

 

 

 

 

 

 

 

 

*Note: Additional power mounts may be required for some runs with T5 HO lamping options, longer runs, and runs with wiring options that are more complex. Please consult factory for assistance.

System Components & Accessories

End Set

BSLESW = suspended standard white

Joiner

BSLJS = suspended joiner

Dust Cover

BSLDCS = 4’ suspended dust cover

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Image 2
Contents Ordering Instructions SpecificationsOrdering Information Performance Run ConfigurationSystem Components & Accessories Module Lengths & Mounting DistancesSupension Length Mounting OptionsMount Type T-Bar 15/16 On-Grid Mount Type T-Bar 9/16 On-GridMount Type Support or Open-Joist Ceiling Mount Type T-Bar Fixed Position 1/4-20 Threaded RodMount Type T-Bar Variable Position Conductor Mount Type Non-Accessible Ceilings concrete, gypsum etcCord Types Circuit Type 1 1cct Wiring Options 1 CircuitCircuit with Emergency Battery Pack EM Type 4 2cct. w/EC/NL Wiring Options 2 Circuit Center/Outer SwitchingCircuit Center/Outer Switching Type 2 2cct Type K Chloride standard C700AType D Chloride standard C700A Circuit A/B Switching alternate 4’ sections Type B 2cctType C 2cct. w/EC/NL Type O Bodine standard B70A