Lightolier Baselyte-BSL2 specifications Mount Type T-Bar Fixed Position 1/4-20 Threaded Rod

Page 4

 

Lighting SystemsBaselyte-BSL2

Page of 8

3 Light T8 Direct/Indirect

Mount Type: T-Bar Fixed Position (1/4-20 Threaded Rod)

1-Power Mount

2-Power Mount

Non-Power Mount

• Meets UBC, OSHPD and DSA seismic requirements

• Canopy: Diameter of 5 1/4“x 3/4” (power)

• Cable: 7x7 stranded aircraft cable

Tile cut-out hole: Diameter of 2 1/2” (power) or 3/4” (non-power)

J-Box: Integral J-Box supplied

1-Power Mount

3Conductor

4Conductor

2-Power Mount

3 Conductor

Supension Length

2’

4’

8’

12’

 

 

 

 

BSLM2102P13

BSLM2104P13

BSLM2108P13

BSLM2112P13

 

 

 

 

BSLM2102P14

BSLM2104P14

BSLM2108P14

BSLM2112P14

 

 

 

 

 

 

 

 

BSLM2102P23

BSLM2104P23

BSLM2108P23

BSLM2112P23

 

 

 

 

1/4 - 20 all thread rod (supplied by others)

Fully vertically adjustable at fixture

Non-Power Mount BSLM2102N

BSLM2104N

BSLM2108N

BSLM2112N

Mount Type: T-Bar Variable Position

1-Power Mount

2-Power Mount

Non-Power Mount

Meets UBC, OSHPD and DSA seismic requirements

Canopy: Diameter of 3“x 7/32”

Cable: 7x7 stranded aircraft cable

Tile cut-out hole: Diameter of 2 1/4”

Aligned by T-bar and secured to structure

J-Box 4” square (supplied by others)

Fully vertically adjustable at fixture

Adjusts to both 1” and 1 1/2” high T-bar systems

1-Power Mount

3Conductor

4Conductor

7Conductor

2-Power Mount

3 Conductor

Supension Length

2’

4’

8’

12’

 

 

 

 

BSLM5102P13

BSLM5104P13

BSLM5108P13

BSLM5112P13

 

 

 

 

BSLM5102P14

BSLM5104P14

BSLM5108P14

BSLM5112P14

 

 

 

 

BSLM5102P17

BSLM5104P17

BSLM5108P17

BSLM5112P17

 

 

 

 

 

 

 

 

BSLM5102P23

BSLM5104P23

BSLM5108P23

BSLM5112P23

 

 

 

 

*Note: Supports 15/16”, 9/16” and slot grid ceiling types.

Non-Power Mount

BSLM5102N

BSLM5104N

BSLM5108N

BSLM5112N

Mount Type: Support or Open-Joist Ceiling

1-Power Mount

2-Power Mount

Non-Power Mount

Meets UBC, OSHPD and DSA seismic requirements

Canopy: Diameter of 5 1/4“x 3/4(power)

• Cable: 7x7 stranded aircraft cable

Versatile mount, fully adjustable to accomodate open sloped ceilings

J-Box: 4” octogonal box (supplied by others)

1-Power Mount

3Conductor

4Conductor

7Conductor

2-Power Mount

3 Conductor

Supension Length

2’

4’

8’

12’

 

 

 

 

BSLM3102P13

BSLM3104P13

BSLM3108P13

BSLM3112P13

 

 

 

 

BSLM3102P14

BSLM3104P14

BSLM3108P14

BSLM3112P14

 

 

 

 

BSLM3102P17

BSLM3104P17

BSLM3108P17

BSLM3112P17

 

 

 

 

 

 

 

 

BSLM3102P23

BSLM3104P23

BSLM3108P23

BSLM3112P23

 

 

 

 

• Fully vertically adjustable at fixture

Non-Power Mount BSLM3102N

BSLM3104N

BSLM3108N

BSLM3112N

Job Information

Type:

Lightolier a Genlyte Company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.1

Image 4
Contents Ordering Information SpecificationsOrdering Instructions Run Configuration System Components & AccessoriesPerformance Module Lengths & Mounting DistancesMounting Options Mount Type T-Bar 15/16 On-GridSupension Length Mount Type T-Bar 9/16 On-GridMount Type T-Bar Variable Position Mount Type T-Bar Fixed Position 1/4-20 Threaded RodMount Type Support or Open-Joist Ceiling Cord Types Mount Type Non-Accessible Ceilings concrete, gypsum etcConductor Circuit with Emergency Battery Pack EM Wiring Options 1 CircuitCircuit Type 1 1cct Wiring Options 2 Circuit Center/Outer Switching Circuit Center/Outer Switching Type 2 2cctType 4 2cct. w/EC/NL Type K Chloride standard C700ACircuit A/B Switching alternate 4’ sections Type B 2cct Type C 2cct. w/EC/NLType D Chloride standard C700A Type O Bodine standard B70A