Samsung SID-600P manual Sync, Special, Phase

Page 18
CTRL TYPE
This function is not used on the Anti-Vandal Dome Camera.
RS485
Select the Baud Rate (4800, 9600, 19200, or 38400 bps) and Camera Address (0~255) for RS485 communication. When using a multiple number of cameras, each must use a different address. (If the same address is used, communica- tion may not be possible.)
PRESET
You can select and store the desired ZOOM and FOCUS positions from 0 to 9.
D-ZOOM
Sets the magnification of the Digital Zoom. Magnification can be set between 2x and 10x in 5 step increments.
PIP
Picture In Picture function. Shows a 1/16 screen only when operating the Digital Zoom. If the D-ZOOM is OFF, a ‘disbled’ symbol (—) will be displayed.
MIRROR
Horizontally flips the video output signal.
POSI/NEGA
Outputs the video output signal normally or inversely.
ZOOM SPEED
Sets the Zoom speed. Pressing the [LEFT, RIGHT] keys in the ZOOM SPEED menu will change the zoom speed as follows:
1 : Takes about 14 seconds from 1x to x12 Slowest speed
2 : Takes about 6 seconds from 1x to x12 Slow speed
3 : Takes about 4 seconds from 1x to x12 Fast speed
4 : Takes about 2 seconds from 1x to x12 Fastest speed
DETAIL
Adjusts the horizontal and vertical sharpness.
If you select ON and press the [ENTER] key, a “SPECIAL” submenu screen where you can set special functions will be displayed.

00356A SID-600P-eng 12/10/02 12:14 PM Page 34

CAMERA MENU Organization

SYNC

Select INT when using the interal synchronization. LINE... is necessary when syn- chronizing the camera phases to operate multiple cameras by using the external signal (AC signal -60Hz(NTSC), AC signal -50Hz(PAL)).

EYou can adjust the PHASE to eliminate any phase deviation between each CAM- ERA set.

CAMERA ID

OFF...

 

 

(LINE LOCK)

IRIS

ALC...

 

 

 

 

AUTO FOCUS

AF

 

 

 

 

SHUTTER

AUTO X8

 

 

 

 

MOTION

F.FAST

 

 

 

 

WHITE BAL

ATW

When you press

 

 

SYNC

 

LINE...

 

 

 

the [ENTER] key

 

 

SPECIAL

...

PHASE

(000) --------

 

 

MOTION DET

OFF

 

 

RET

EXIT

QUIT

 

 

 

 

You can use this function when using the AC power.

With the DC voltage, you will not be able to set the SYNC with —-.

Position the cursor on the SYNC and use the [LEFT/RIGHT] keys to select the desired sychronization from INT/LINE... When you select LINE... and press the [ENTER] key, a submenu screen where you can adjust the PHASE will appear.

You can adjust the PHASE for NTSC from -106 to +106, and for PAL from -138 to +138.

SPECIAL

In the SPECIAL menu, you can directly control the POSI/NEGA, PIP, MIRROR, horizontal sharpness, and vertical sharpness.

34

E

35

Image 18
Contents SID-600P Important Safety Instructions Risk of Electric Shock do not OpenTable of Contents Chapter OverviewIntroduction Part Names and Functions Installing the Camera Usual operation modeNow, let’s install the Camera and connect cables Before Installation Checking the Contents of the PackageIt can be directly installed on ceilings Precautions for Installation and UseInstallation Examples These items are sold separatelyPower Adapter Cable Preparing Cables Installing the CameraFor installing directly on a ceiling Video CableFor installing on a pipe For installing on a pipe coming down from the ceilingFasten the supplied Assy Screw Machine For installing on a horizontal pipe Adjust the Lens direction and assemble the Dome Cover Connecting Cables and Checking Operations Structure of the Setup Menu Setup Menu OverviewIris Camera Menu OrganizationCamera ID Means that there is a submenu Size Auto Focus Manu Manual Iris LevelShutter AGC/MOTIONMotion Set the White BAL menu to ATW White BALATW AWCSpecial PhaseSync SyncPreset ID Position SETStores the Zoom and Focus positions Motion DET ExitDescription Operating Temperature 10C ~ +50C 14F~122FApprox kg/2.2lb