Samsung AQV18UGDNEUR manual Using the Smart Saver function, From the moment you have set the timer

Page 15

Combining On Timer and Off Timer

If the air conditioner is on

If the air conditioner is off

 

 

Preset time on On timer is longer than Off timer

Preset time on On timer is shorter than Off timer

Ex) On timer : 3 hours, Off timer : 1 hour

Ex) On timer : 3 hours, Off timer : 5 hours

- The air conditioner will operate the Off timer after

- The air conditioner will operate On timer after 3 hours

1 hour from the moment you have set the timer.

from the moment you have set the timer.

Your air conditioner will turn on after 2 hours.

Your air conditioner will remain on for 2 hours and then

 

turn off automatically.

 

 

ENGLISH

• On timer and Off timer setting time should be different from each other.

• Press the Cancel button on the remote controller while timer combination is on. Both of the On and Off timer will be canceled and the indicator will disappear.

Using the Smart Saver function

This function will set the temperature range limit to help you save energy while the air conditioner is operating in Cool mode.

Press the Smart Saver button on the remote controller while the air conditioner is operating in Cool mode.

Smart Saver indicator and air swing indicator appears automatically on the remote controller display.

The air flow blades move up and down.

If the current set temperature is lower than 24°C, it will automatically raise to 24°C.

Cancel Press the Smart Saver button once again.

• Smart Saver function is only available in Cool mode.

• When Smart Saver function is activated, temperature range will be limited to 24°C~30°C.

If the desired temperature is lower than 24°C, turn off the Smart Saver function by pressing the Smart Saver button again.

Temperature/Fan speed can also be adjusted (see page 11 for instructions).

Air flow can be adjusted manually (see page 12 for instructions).

If you press the Mode button while the Smart Saver function is on, it will cancel the function.

15

Vivaldi MAX EUR_AQV09&12U@@ IB&IM_33988A_EN-5.indd 15

2014/12/11 18:24:21

Image 15
Contents Vivaldi MAX EURAQV09&12U@@ IB&IM33988AEN-5.indd 2014/12/11 Contents Wall socket Safety precautionsImportant safety symbols and precautions Follow directionsFor Using For Cleaning Operation ranges Checking before useDisplay Power buttonChecking the name of the parts Main partsRemote controller buttons Checking the remote controllerInserting the batteries Remote controller displayBattery changing time Storing the remote controllerBasic function Press Button to adjust the temperatureVertical air flow Adjusting the air flow directionUsing the Turbo function Press the Air swing button on the remote controllerPress the Time Up or Time Down button to set the time When the air conditioner is on and in cool/heat modePress the button on the remote controller ModeAdditional options available in On timer mode Setting the On/Off timerPress the On Timer/Off Timer button Cancel Press the Cancel buttonTurn off automatically Using the Smart Saver functionFrom the moment you have set the timer If the air conditioner is on If the air conditioner is offYou can reduce the noise generated from an indoor unit Using the Quiet functionUsing the Auto Clean function When the air conditioner is turned onOpening the panel Cleaning the air conditionerCleaning the indoor unit Cleaning the outdoor unit heat exchangerDry the Air filter in a ventilated area Cleaning the air filterRemoving the Air filter Open the panel and put the Air filter outPeriodical checks Maintaining the air conditionerTroubleshooting Outdoor unit Heat exchanger during Heat mode in winter Flow movement changes. It is normalConnection General information  a place where the air filter can be replaced easily Choosing the installation locationInstalling the unit Power supply line, fuse or circuit breakerWhere sulfide gas exists Outdoor UnitModel Top view Side view When installing more than 1 outdoor unitWhen the air outlet is towards the wall  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case Tools for test operations Fixing the installation plateOptional accessories Tools required for installation General ToolsIf you fix the indoor unit on a gypsum board Connecting the cableFix the indoor unit If you fix the indoor unit on a wall If you fix the indoor unit on a window frameExtend the assembly cable if necessary Cut off the remaining foam insulation Smooth the cut edgesPut a flare nut slightly into the pipe and modify the flare Purging the indoor unitCutting or extending the pipe Unscrew the caps at the end of each pipeOuter Diameter Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined CrackedDrain hose installation Purging the connected pipes Connect a drain hose to the drain plugEnsure that condensation draining is adequate Adding Refrigerant Please fill in with indelible ink  the factory refrigerant charge of the product2088 Leak test with nitrogen before opening valves Performing the gas leak testsTo check for gas leaks on the outdoor unit To check for gas leaks on the indoor unitFixing the outdoor unit in place Outdoor unit installed on the wall by rackThen place the indoor unit on the installation plate Fixing the indoor unit in placeFinal Check and Trial Operation Insulation tape to finish How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish Questions or COMMENTS? Air Conditioner
Related manuals
Manual 41 pages 47.02 Kb Manual 21 pages 20.86 Kb Manual 39 pages 33.67 Kb Manual 41 pages 50.29 Kb Manual 43 pages 23.26 Kb Manual 41 pages 10.61 Kb Manual 43 pages 43.79 Kb Manual 41 pages 45.51 Kb Manual 23 pages 13.22 Kb Manual 41 pages 16.8 Kb Manual 41 pages 63.42 Kb Manual 21 pages 17.82 Kb Manual 43 pages 57.8 Kb

AQV09UGFNEUR, AQV09PWCNEUR, AQV10UWFNEUR, AQV24UGDNEUR, AQV09UGFXEUR specifications

Samsung air conditioning units, including models AQV18UGDNEUR, AQV12UGFXEUR, AQV18UGDXEUR, AQV12UGFNEUR, and AQV24UGDXEUR, epitomize the brand's commitment to innovation and efficiency. These models combine cutting-edge technology with user-friendly features, ensuring optimal performance in various settings, from residential to commercial spaces.

The AQV series is equipped with Samsung's Digital Inverter technology, which enhances energy efficiency by adjusting the compressor speed based on the cooling demand. This allows the units to maintain the desired temperature without the constant on-off cycling seen in traditional air conditioning systems, resulting in significant energy savings and reduced operational costs.

In addition to energy efficiency, these models prioritize user comfort. They feature a range of airflow settings, including Smart Wind technology, which allows for customizable air distribution. This ensures that every corner of the room is evenly cooled or heated, eliminating hot or cold spots. The models also come with a quiet operation mode, minimizing noise levels for a peaceful indoor environment.

One of the standout characteristics of the AQV series is their advanced filtration system. These units come with a multi-layered filter that captures dust, pollen, and other allergens, promoting cleaner air quality. The filters are also designed for easy maintenance, ensuring that users can keep their systems operating effectively with minimal hassle.

Connectivity is another key feature of the Samsung AQV series. Many of these models are compatible with smart home systems, allowing users to control their air conditioning from their smartphones or voice assistants. This integration provides convenience and allows for scheduling, enabling users to optimize their cooling or heating preferences based on their daily routines.

Moreover, the design of the AQV series is sleek and modern, making them aesthetically pleasing additions to any interior. Their compact size means they can fit into various spaces without compromising on performance.

In summary, the Samsung AQV18UGDNEUR, AQV12UGFXEUR, AQV18UGDXEUR, AQV12UGFNEUR, and AQV24UGDXEUR air conditioning units exemplify reliability, efficiency, and user-friendly features. With advanced technologies, smart capabilities, and a focus on air quality, these models are excellent choices for anyone looking to enhance their indoor comfort while keeping energy consumption in check.