Fixing the indoor unit in place

Perform the following work on the area where gas leak test was done priorly.

After checking for gas leaks in the system, insulate the pipe, hose and cables.

Insulation

Then place the indoor unit on the installation plate.

 

1. To avoid condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes.

Pipes

2.Wind the pipe, assembly cable and drain hose with vinyl tape.

3.Place the bundle (the pipe, assembly cable and drain hose) in the lower part of the indoor unit carefully so it does not project from the rear of the indoor unit.

4.Hook the indoor unit to the installation plate and move the unit to the right and left until it is securely in place.

Installation

 

plate

Connecting

Vinyl tape

pipes

Connecting wires

 

Drain hose

 

• Make sure pipe does not move when you install the indoor unit on an installation plate.

5.Wrap the rest of the pipe with vinyl tape.

6.Attach the pipe to the wall using clamps (optional).

Fixing the outdoor unit in place

Install the outdoor unit in level on a stable base to avoid the generation of noise and vibration, especially when installing the unit close to a neighbor.

If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an appropriate support (wall or ground).

1.Place the outdoor unit as indicated on the top of the unit to let the discharged air out properly.

2.Fix the outdoor unit in level to an appropriate support using anchor bolts.

3.If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly.

• Secure the rubber leg to prevent the generation of noise and vibration.

Outdoor unit installed on the wall by rack

• Ensure the wall will be able to suspend the weight of rack and outdoor unit;

• Install the rack close to the column as much as possible;

• Install proper grommet in order to reduce noise and residual vibration transferred by outdoor unit towards wall.

'X' mm

'Y' mm

Rubber leg

Model

X Y

09/10/12 538 290

18

612 317

24

660 340

Designed to cut off residual vibration from outdoor unit to rack.

(not supplied with product)

Soft rubber designed to cut off vibration from rack to wall. (not supplied with product)

38

Vivaldi MAX EUR_AQV09&12U@@ IB&IM_33988A_EN-5.indd 38

2014/12/11 18:24:30

Image 38
Contents Vivaldi MAX EURAQV09&12U@@ IB&IM33988AEN-5.indd 2014/12/11 Contents Follow directions Safety precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning Checking before use Operation rangesMain parts Power buttonChecking the name of the parts DisplayChecking the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic function Button to adjust the temperature PressPress the Air swing button on the remote controller Adjusting the air flow directionUsing the Turbo function Vertical air flowMode When the air conditioner is on and in cool/heat modePress the button on the remote controller Press the Time Up or Time Down button to set the timeCancel Press the Cancel button Setting the On/Off timerPress the On Timer/Off Timer button Additional options available in On timer modeIf the air conditioner is on If the air conditioner is off Using the Smart Saver functionFrom the moment you have set the timer Turn off automaticallyWhen the air conditioner is turned on Using the Quiet functionUsing the Auto Clean function You can reduce the noise generated from an indoor unitCleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit Opening the panelOpen the panel and put the Air filter out Cleaning the air filterRemoving the Air filter Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Connection Outdoor unit Heat exchanger during Heat mode in winterFlow movement changes. It is normal General information Power supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyModel Where sulfide gas existsOutdoor Unit  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall Top view Side viewAccessories in the outdoor unit case AccessoriesAccessories in the indoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsIf you fix the indoor unit on a window frame Connecting the cableFix the indoor unit If you fix the indoor unit on a wall If you fix the indoor unit on a gypsum boardExtend the assembly cable if necessary Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Purging the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareCracked Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined Outer DiameterDrain hose installation Ensure that condensation draining is adequate Purging the connected pipesConnect a drain hose to the drain plug Adding Refrigerant 2088 Please fill in with indelible ink the factory refrigerant charge of the product To check for gas leaks on the indoor unit Performing the gas leak testsTo check for gas leaks on the outdoor unit Leak test with nitrogen before opening valvesFixing the indoor unit in place Outdoor unit installed on the wall by rackThen place the indoor unit on the installation plate Fixing the outdoor unit in placeFinal Check and Trial Operation After tube contraction work is completed, wrap it with How to connect your extended power cablesApply heat to the contraction tube to contract it Insulation tape to finishEnglish Questions or COMMENTS? Air Conditioner
Related manuals
Manual 41 pages 47.02 Kb Manual 21 pages 20.86 Kb Manual 39 pages 33.67 Kb Manual 41 pages 50.29 Kb Manual 43 pages 23.26 Kb Manual 41 pages 10.61 Kb Manual 43 pages 43.79 Kb Manual 41 pages 45.51 Kb Manual 23 pages 13.22 Kb Manual 41 pages 16.8 Kb Manual 41 pages 63.42 Kb Manual 21 pages 17.82 Kb Manual 43 pages 57.8 Kb

AQV09UGFNEUR, AQV09PWCNEUR, AQV10UWFNEUR, AQV24UGDNEUR, AQV09UGFXEUR specifications

Samsung air conditioning units, including models AQV18UGDNEUR, AQV12UGFXEUR, AQV18UGDXEUR, AQV12UGFNEUR, and AQV24UGDXEUR, epitomize the brand's commitment to innovation and efficiency. These models combine cutting-edge technology with user-friendly features, ensuring optimal performance in various settings, from residential to commercial spaces.

The AQV series is equipped with Samsung's Digital Inverter technology, which enhances energy efficiency by adjusting the compressor speed based on the cooling demand. This allows the units to maintain the desired temperature without the constant on-off cycling seen in traditional air conditioning systems, resulting in significant energy savings and reduced operational costs.

In addition to energy efficiency, these models prioritize user comfort. They feature a range of airflow settings, including Smart Wind technology, which allows for customizable air distribution. This ensures that every corner of the room is evenly cooled or heated, eliminating hot or cold spots. The models also come with a quiet operation mode, minimizing noise levels for a peaceful indoor environment.

One of the standout characteristics of the AQV series is their advanced filtration system. These units come with a multi-layered filter that captures dust, pollen, and other allergens, promoting cleaner air quality. The filters are also designed for easy maintenance, ensuring that users can keep their systems operating effectively with minimal hassle.

Connectivity is another key feature of the Samsung AQV series. Many of these models are compatible with smart home systems, allowing users to control their air conditioning from their smartphones or voice assistants. This integration provides convenience and allows for scheduling, enabling users to optimize their cooling or heating preferences based on their daily routines.

Moreover, the design of the AQV series is sleek and modern, making them aesthetically pleasing additions to any interior. Their compact size means they can fit into various spaces without compromising on performance.

In summary, the Samsung AQV18UGDNEUR, AQV12UGFXEUR, AQV18UGDXEUR, AQV12UGFNEUR, and AQV24UGDXEUR air conditioning units exemplify reliability, efficiency, and user-friendly features. With advanced technologies, smart capabilities, and a focus on air quality, these models are excellent choices for anyone looking to enhance their indoor comfort while keeping energy consumption in check.