Samsung AQV18UGDXEUR manual Purging the connected pipes, Connect a drain hose to the drain plug

Page 34

Installing and connecting the drain hose of the outdoor unit

While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate

draining, do the following:

1. Insert the drain plug into the drain hole on the underside of the outdoor unit.

• To avoid drain plug from contacting the ground, secure gap between the

Drain hole

 

ground and the bottom surface of the outdoor unit.

Drain plug

 

 

 

 

Bottom surface of outdoor unit

2. Connect a drain hose to the drain plug.

Drain hole

Drain plug

Drain hose

 

Snow-proof hood

3. Ensure that condensation draining is adequate.

In areas with heavy snow fall, piled snow could block the air intake.

To avoid this incident, install a frame that is higher than estimated snow fall. In addition, install a snow-proof hood to avoid snow from piling on the outdoor unit.

Estimated

 

snow fall

Frame

 

Ground

Purging the connected pipes

The outdoor unit is loaded with sufficient R410A refrigerant. Do not vent R410A into atmosphere: it is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 2088.

You should purge the air in the indoor unit and in the pipe. If air remains in the refrigerant pipes, it affects the compressor. It may cause reduction of cooling capacity and malfunction. Refrigerant for air purging is not charged in the outdoor unit. Use Vacuum Pump as seen in the picture.

• When installing, make sure there is no leakage. When recovering the refrigerant, ground the compressor first

before removing the connection pipe. If the refrigerant pipe is not properly connected and the compressor works with the service valve open, the pipe inhales the air and it makes the pressure inside of the refrigerant cycle

abnormally high. It may cause explosion and injury.

1.Connect each assembly pipe to the appropriate valve on the outdoor unit and tighten the flare nut.

2.Tighten the flare nut first with your hands, and then with a torque wrench, applying the following torque:

• Excessive torque can be cause of gas leakage.

• Make the electrical connection and leave the system into“stand by mode”. Do not turn on the system!

This is necessary for better vacuum operation (full OPEN position of Electronic Expansion Valve - EEV -).

Outdoor unit

Indoor unit

 

Gas pipe side

 

Liquid pipe side

Outer Diameter

Torque (kgf•cm)

ø6.35 mm

140~170

ø9.52 mm

250~280

ø12.70 mm

380~420

ø15.88 mm

440~480

ø19.05 mm

990~1210

ø22.23 mm

990~1210

34

Vivaldi MAX EUR_AQV09&12U@@ IB&IM_33988A_EN-5.indd 34

2014/12/11 18:24:29

Image 34
Contents Vivaldi MAX EURAQV09&12U@@ IB&IM33988AEN-5.indd 2014/12/11 Contents Follow directions Safety precautionsImportant safety symbols and precautions Wall socketFor Using For Cleaning Checking before use Operation rangesMain parts Power buttonChecking the name of the parts DisplayChecking the remote controller Remote controller buttonsStoring the remote controller Remote controller displayBattery changing time Inserting the batteriesBasic function Button to adjust the temperature PressPress the Air swing button on the remote controller Adjusting the air flow directionUsing the Turbo function Vertical air flowMode When the air conditioner is on and in cool/heat modePress the button on the remote controller Press the Time Up or Time Down button to set the timeCancel Press the Cancel button Setting the On/Off timerPress the On Timer/Off Timer button Additional options available in On timer modeIf the air conditioner is on If the air conditioner is off Using the Smart Saver functionFrom the moment you have set the timer Turn off automaticallyWhen the air conditioner is turned on Using the Quiet functionUsing the Auto Clean function You can reduce the noise generated from an indoor unitCleaning the outdoor unit heat exchanger Cleaning the air conditionerCleaning the indoor unit Opening the panelOpen the panel and put the Air filter out Cleaning the air filterRemoving the Air filter Dry the Air filter in a ventilated areaMaintaining the air conditioner Periodical checksTroubleshooting Flow movement changes. It is normal Outdoor unit Heat exchanger during Heat mode in winterConnection General information Power supply line, fuse or circuit breaker Choosing the installation locationInstalling the unit  a place where the air filter can be replaced easilyOutdoor Unit Where sulfide gas existsModel  Figure Description When installing more than 1 outdoor unitWhen the air outlet is towards the wall Top view Side viewAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case Tools required for installation General Tools Fixing the installation plateOptional accessories Tools for test operationsIf you fix the indoor unit on a window frame Connecting the cableFix the indoor unit If you fix the indoor unit on a wall If you fix the indoor unit on a gypsum boardExtend the assembly cable if necessary Smooth the cut edges Cut off the remaining foam insulationUnscrew the caps at the end of each pipe Purging the indoor unitCutting or extending the pipe Put a flare nut slightly into the pipe and modify the flareCracked Pipe 50 Pa. The joint must be accessible and serviceableCorrect Inclined Outer DiameterDrain hose installation Connect a drain hose to the drain plug Purging the connected pipesEnsure that condensation draining is adequate Adding Refrigerant  the factory refrigerant charge of the product Please fill in with indelible ink2088 To check for gas leaks on the indoor unit Performing the gas leak testsTo check for gas leaks on the outdoor unit Leak test with nitrogen before opening valvesFixing the indoor unit in place Outdoor unit installed on the wall by rackThen place the indoor unit on the installation plate Fixing the outdoor unit in placeFinal Check and Trial Operation After tube contraction work is completed, wrap it with How to connect your extended power cablesApply heat to the contraction tube to contract it Insulation tape to finishEnglish Questions or COMMENTS? Air Conditioner
Related manuals
Manual 41 pages 47.02 Kb Manual 21 pages 20.86 Kb Manual 39 pages 33.67 Kb Manual 41 pages 50.29 Kb Manual 43 pages 23.26 Kb Manual 41 pages 10.61 Kb Manual 43 pages 43.79 Kb Manual 41 pages 45.51 Kb Manual 23 pages 13.22 Kb Manual 41 pages 16.8 Kb Manual 41 pages 63.42 Kb Manual 21 pages 17.82 Kb Manual 43 pages 57.8 Kb

AQV09UGFNEUR, AQV09PWCNEUR, AQV10UWFNEUR, AQV24UGDNEUR, AQV09UGFXEUR specifications

Samsung air conditioning units, including models AQV18UGDNEUR, AQV12UGFXEUR, AQV18UGDXEUR, AQV12UGFNEUR, and AQV24UGDXEUR, epitomize the brand's commitment to innovation and efficiency. These models combine cutting-edge technology with user-friendly features, ensuring optimal performance in various settings, from residential to commercial spaces.

The AQV series is equipped with Samsung's Digital Inverter technology, which enhances energy efficiency by adjusting the compressor speed based on the cooling demand. This allows the units to maintain the desired temperature without the constant on-off cycling seen in traditional air conditioning systems, resulting in significant energy savings and reduced operational costs.

In addition to energy efficiency, these models prioritize user comfort. They feature a range of airflow settings, including Smart Wind technology, which allows for customizable air distribution. This ensures that every corner of the room is evenly cooled or heated, eliminating hot or cold spots. The models also come with a quiet operation mode, minimizing noise levels for a peaceful indoor environment.

One of the standout characteristics of the AQV series is their advanced filtration system. These units come with a multi-layered filter that captures dust, pollen, and other allergens, promoting cleaner air quality. The filters are also designed for easy maintenance, ensuring that users can keep their systems operating effectively with minimal hassle.

Connectivity is another key feature of the Samsung AQV series. Many of these models are compatible with smart home systems, allowing users to control their air conditioning from their smartphones or voice assistants. This integration provides convenience and allows for scheduling, enabling users to optimize their cooling or heating preferences based on their daily routines.

Moreover, the design of the AQV series is sleek and modern, making them aesthetically pleasing additions to any interior. Their compact size means they can fit into various spaces without compromising on performance.

In summary, the Samsung AQV18UGDNEUR, AQV12UGFXEUR, AQV18UGDXEUR, AQV12UGFNEUR, and AQV24UGDXEUR air conditioning units exemplify reliability, efficiency, and user-friendly features. With advanced technologies, smart capabilities, and a focus on air quality, these models are excellent choices for anyone looking to enhance their indoor comfort while keeping energy consumption in check.