Samsung AR24KPFNDWK/SG Outdoor Unit, English-33, Where sulfide gas exists, Noise and vibration

Page 33

Choosing the installation location

Outdoor Unit

Where it is not exposed to strong wind

Well ventilated and dustless places

Where possible keep out of sunlight and rain

Where neighbors are not annoyed by operation sound or hot air

Solid wall or support that prevents vibration and is strong enough to hold the product weight

Where there is no risk of flammable gas leakage

When installing the unit at a high place be sure to fix the unit legs

3 m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated)

Install the unit horizontally

Place where drained water does not become any problem.

Place with no plants (especially climbing plants) and where small animal can not access.

Outdoor unit should not be place higher than 2.4 m or directly under eaves for accessibility for service and OH&S reasons.

• Avoid the following places to prevent malfunction of the unit

- Where there is machine oil

- Salty environment such as seaside areas

- Where sulfide gas exists

- Other special atmosphere areas

07stIn llan atio

Outdoor

 

Unit

 

Outer wall

Indoor

A

 

Unit

 

 

Cut insulation to

 

have rainwater

 

drained

Make an U-trap(A) on the pipe (which is connected to the indoor unit) at outer wall and cut the bottom part of the insulation (about 10 mm) to prevent rainwater from getting inside through the insulation. However, be careful not to damage the pipe.

100 mm or more

 

125 mm

125 mm or

or more

more

You can select the direction

 

of draining (left or right).

 

Wrap the refrigerant pipes and the

 

drain hose with the absorbent pad

 

and vinyl tape. Refer to page 50 for

 

further details.

 

'L' m as maximum pipe

'H' meters

length and 3 m as minimum

maximum

pipe length. (It will reduce

total pipe

noise and vibration)

height

 

'L' meters maximum total pipe length

Make at least one round: It will help reduce

noise and vibration.

Model

Pipe Length

Pipe Height

Minimum

Maximum

Maximum

 

✴✴09/12✴✴

3

15

7

✴✴18✴✴

 

 

 

✴✴24✴✴

3

20

8

 

 

 

 

The appearance of the unit may be different from the diagram depending on the model.

English-33

SG_GOOD_A3050_IB&IM_EN_DB68-05200A-03.indd 33

2/2/2016 8:26:13 AM

Image 33
Contents Air Conditioner Features of your new air conditioner Contents English-4 Safety precautions01epPr aration English-5English-6 For UsingEnglish-7 English-8 Do not place objects or devices under the indoor unitEnglish-9 For CleaningChecking before use Operation rangesEnglish-10 Main parts Checking the name of the partsFor model ARKPFN DisplayChecking the remote controller Remote controller buttonsEnglish-12 Low Battery warning Remote controller displayStoring the remote controller Inserting the batteriesBasic function Press the button to adjust the temperature Press the button to set the desired fan speedEnglish-15 Vertical air flow Adjusting the air flow directionHorizontal air flow English-16Setting the On timer Setting the On/Off timerSet the timer to press the SET button You can adjust the fan speed in Cool/Fan/Heat modeSet the timer to Setting the Off timerEnglish-18 Button Additional options available in mode ModeEnglish-19 English-20 Step cooling functionUsing the Fast function Using the Comfort functionEnglish-21 Using the Single User function English-22Press the Single user button Using the Auto Clean function Setting the Beep soundEnglish-23 Cleaning the indoor unit Cleaning the air conditionerCleaning the outdoor unit heat exchanger English-24Removing the Air filter Cleaning the air filterEnglish-25 Remove the air filter from the main bodyRemoving the Air filter English-26Reassembling the Air filter English-27Air filter English-28 Maintaining the air conditionerTroubleshooting Air conditionerEnglish-29 Check the Drains have been cleared Regular Maintenance Button or disconnect the power plug/switch Error is indicated Heard when refrigerant flow movement changes. It is normalGeneral information English-3107stIn llan atio Installing the unit Choosing the installation locationPower supply line, fuse or circuit breaker Indoor unitOutdoor Unit Where sulfide gas existsEnglish-33 Noise and vibrationWhen the air outlet is towards the wall When installing more than 1 outdoor unitEnglish-34  Figure DescriptionAccessories in the indoor unit case AccessoriesAccessories in the outdoor unit case English-35Optional accessories Fixing the installation plateTools required for installation General Tools Tools for test operationsEnglish-37 Assembling the hanger screwOn a Wall On aRemoving the screws This QR code for detail video of indoor unit installationRemoving the Cover panel Before mounting the indoor unit English-38English-39 Assembling the Cover panel After mounting the indoor unitCable specification Connecting the assembly cableConnecting the cable English-40Extend the assembly cable if necessary Each wire is labeled with the corresponding terminal numberEnglish-41 Smooth the cut edges English-42Cut off the remaining foam insulation TorqueEvacuating the indoor unit Cutting or extending the pipeEnglish-43 English-44 Correct InclinedCracked English-45 Drain hose installationChanging direction of the drain hose Change the direction only when it is necessaryEnglish-46 Check for leakage on both side of the drain outletEnglish-47 Evacuating the connected pipesConnect a drain hose to the drain plug Drain hole Drain plugEnglish-48 Adding RefrigerantEnglish-49 Performing the gas leak testsOutdoor unit installed on the wall by rack Fixing the outdoor unit in placeEnglish-50 English-51 Smart Install modeOff / Blinking / On English-52English-53 Final check and trial operationEnglish-54 How to connect your extended power cablesApply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-55 021-8255 CE Questions or COMMENTS?