Samsung AR12HPFSDWK/SG, AR24KPFNDWKNSG, AR18KPFNDWKNSG manual English-52, Off / Blinking / On

Page 52

2) Smart Install mode in progress

88 Display : Progress will be displayed in 0~99..

LED Display : Indicator on the indoor unit display will blink in sequence and then all indicators will blink.. (This will be repeated..)

TYPE

88 Display

LED Display

 

 

LED1

Indoor unit indicator

 

LED2

 

 

LED3

❋❋Display may be different depending on the model..

3..Smart Install mode will end..

1)Smart Install mode will take approximately 7~13 minutes.. (Actual time may be different depending on the model..)

2)When Installation is successful : Smart Install mode will end with ringing sound and the air conditioner will be in standby status.. (Error message will not be displayed on the indoor unit indicator and the remote controller and buttons on the indoor unit will work normally..)

3)When installation is not successful : Smart Install mode will end and error message will be displayed on the indoor unit display..

1. Take necessary measures when error occurs.

--Refer to the service manual for necessary measures for each error that occurs.

2. Use the product after taking care of the error that occurs.

 

Error indicator

 

 

 

 

 

 

 

LED Display

 

 

Error

Measures to take by an installer

Display

LED 1

LED 2

 

LED 3

 

 

 

 

 

 

 

/

/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Communication Error

1.. Check the connection wire between indoor

 

 

 

 

 

 

 

between Indoor and outdoor

and outdoor unit.. (whether the power cable and

 

 

 

 

 

 

 

unit

communication cable is crossed or not)

 

 

 

 

 

 

 

Error on indoor

1. Check the connection of the connector

 

 

 

 

 

 

 

temperature sensor

 

,

 

 

 

 

 

 

Error on indoor heat

1. Check the connection of the connector

 

 

 

 

 

 

exchanger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error on indoor fan

1. Check the connection of the connector

 

 

 

 

 

 

 

2. Remove foreign substance (Check for the

 

 

 

 

 

 

 

motor

 

 

 

 

 

 

 

cause that restrains motor)

 

 

 

 

 

 

 

 

display and all

 

 

 

 

 

 

 

1. Re-set options

LED blinks

 

 

 

 

 

 

EEPROM/Option error

 

,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Check if the service valve is completely open..

 

 

 

 

 

 

 

Refrigerant flow blocking

2. Check if there's any blockage in the refrigerant pipe

 

 

 

 

 

 

 

Error

which connects indoor and outdoor unit..

 

 

 

 

 

 

 

 

3. Check for refrigerant leak..

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Check if sufficient amount of additional refrigerant

 

 

 

 

 

 

 

Lack of Refrigerant (For

was charged for the pipe length that exceeds 7..5 m..

 

Above LED pattern is displayed when there's

 

2. Check for refrigerant leak between valve and pipe

 

 

 

 

 

 

 

Inverter model only)

 

error is occurred on outdoor unit. Check the LED

connection..

 

 

 

display on outdoor unit for the details.

 

 

 

 

 

 

 

 

 

 

 

 

❋❋ : Off / : Blinking / : On

English-52

SG_GOOD_A3050_IB&IM_EN_DB68-05200A-03.indd 52

2/2/2016 8:26:31 AM

Image 52
Contents Air Conditioner Features of your new air conditioner Contents Safety precautions English-4English-5 01epPr arationFor Using English-6English-7 Do not place objects or devices under the indoor unit English-8For Cleaning English-9Operation ranges Checking before useEnglish-10 Checking the name of the parts Main partsFor model ARKPFN DisplayRemote controller buttons Checking the remote controllerEnglish-12 Remote controller display Low Battery warningStoring the remote controller Inserting the batteriesBasic function Press the button to set the desired fan speed Press the button to adjust the temperatureEnglish-15 Adjusting the air flow direction Vertical air flowHorizontal air flow English-16Setting the On/Off timer Setting the On timerSet the timer to press the SET button You can adjust the fan speed in Cool/Fan/Heat modeSetting the Off timer Set the timer toEnglish-18 Button Mode Additional options available in modeEnglish-19 Step cooling function English-20Using the Comfort function Using the Fast functionEnglish-21 English-22 Using the Single User functionPress the Single user button Setting the Beep sound Using the Auto Clean functionEnglish-23 Cleaning the air conditioner Cleaning the indoor unitCleaning the outdoor unit heat exchanger English-24Cleaning the air filter Removing the Air filterEnglish-25 Remove the air filter from the main bodyEnglish-26 Removing the Air filterEnglish-27 Reassembling the Air filterAir filter Maintaining the air conditioner English-28Air conditioner TroubleshootingEnglish-29 Button or disconnect the power plug/switch Check the Drains have been cleared Regular MaintenanceError is indicated Heard when refrigerant flow movement changes. It is normalEnglish-31 General information07stIn llan atio Choosing the installation location Installing the unitPower supply line, fuse or circuit breaker Indoor unitWhere sulfide gas exists Outdoor UnitEnglish-33 Noise and vibrationWhen installing more than 1 outdoor unit When the air outlet is towards the wallEnglish-34  Figure DescriptionAccessories Accessories in the indoor unit caseAccessories in the outdoor unit case English-35Fixing the installation plate Optional accessoriesTools required for installation General Tools Tools for test operationsAssembling the hanger screw English-37On a Wall On aThis QR code for detail video of indoor unit installation Removing the screwsRemoving the Cover panel Before mounting the indoor unit English-38Assembling the Cover panel After mounting the indoor unit English-39Connecting the assembly cable Cable specificationConnecting the cable English-40Each wire is labeled with the corresponding terminal number Extend the assembly cable if necessaryEnglish-41 English-42 Smooth the cut edgesCut off the remaining foam insulation TorqueCutting or extending the pipe Evacuating the indoor unitEnglish-43 Correct Inclined English-44Cracked Drain hose installation English-45Change the direction only when it is necessary Changing direction of the drain hoseEnglish-46 Check for leakage on both side of the drain outletEvacuating the connected pipes English-47Connect a drain hose to the drain plug Drain hole Drain plugAdding Refrigerant English-48 Performing the gas leak tests English-49Fixing the outdoor unit in place Outdoor unit installed on the wall by rackEnglish-50 Smart Install mode English-51English-52 Off / Blinking / OnFinal check and trial operation English-53How to connect your extended power cables English-54Apply heat to the contraction tube to contract it After tube contraction work is completed, wrap it withEnglish-55 Questions or COMMENTS? 021-8255 CE