Lytecaster® Recessed Downlighting 1100AICM
Page of 1 | 6 3/4” Aperture Incandescent Insulated Ceiling, AirSeal® | |
| Downlighting | 0194 |
5 /2"
1
7
3
7 5/6"
2 4
9" | /8" |
|
5 |
|
6 | REFLECTOR TRIM |
|
63/6" Dia. Ceiling Opening
Complete Fixture consists Completeof ReflectorFixtu eTrimconsists& Frameof
| Reflector Trims — See Individual Reflector Trim Specification Sheets |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Open Downlight |
|
| Adjustable | Enclosed | Open Wet | Wall | ||
|
|
|
|
|
|
|
|
|
| |||
|
| Reflector | Satin | Sloped | Baffles | Basic | Cross | Recessed | Recessed | |||
|
| Diffusers | Location | Washer | ||||||||
|
|
| Cone | Ceiling |
| White | Blade | Line Volt. | Low Volt. | |||
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1100AICM | 1143 | 1108 | 1131 | 1105 | 1170M1 | 1132 | 1129NM | 1155 | 1121 | 1184CD | 1185 |
| 1144 | 1108NM | 1131WH | 1105WH | 1171 |
| 1129 | 1155WH | 1124 | 1184WH | 1186 | |
|
|
| ||||||||||
|
| 1144CD | 1110 | 1131GD | 1105NM |
|
| 1129CD | 1161 | 1126 |
| 1186WH |
|
|
| 1110NM | 1131CL | 1105BNM |
|
| 1129CDNM | 1161WH | 1128 |
|
|
|
|
|
| 1131BK | 1176 |
|
| 1129WH | 1163 | 1134 |
|
|
|
|
|
|
|
|
|
| |||||
|
| Cone: |
| 1133 | 1176WH |
|
| 1129CL | 1164 | 1177SH |
|
|
|
|
|
| 1133WH | 1179M1 |
|
| 1129GD |
| 1178SH |
|
|
|
| 1112 |
|
|
|
|
|
| ||||
|
|
| 1133GD | 1179WH |
|
| 1129BK |
| 1190 |
|
| |
|
| 1112NM |
|
|
|
|
|
| ||||
|
|
| 1133CL |
|
|
|
|
|
|
|
| |
|
| 1113 |
|
|
|
|
|
|
|
|
| |
|
|
| 1133BK |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Eyeball |
|
|
|
| ||
|
| 1113BK |
|
|
|
|
|
|
|
| ||
|
|
| 1154 |
|
|
|
|
|
|
| ||
|
| 1113WH |
|
|
|
|
|
|
|
|
| |
|
|
| 1154WH |
|
|
| 1122 |
|
|
|
| |
|
| 1113CD |
|
|
|
|
|
|
|
| ||
|
|
| 1154BK |
|
|
|
|
|
|
| ||
|
|
|
|
|
| 1123 |
|
|
|
| ||
|
| 1113NM |
|
|
|
|
|
|
|
| ||
|
|
| 1154GD |
|
|
|
|
|
|
| ||
|
|
|
|
|
| 1182 |
|
|
|
| ||
|
| 1113BKNM |
|
|
|
|
|
|
|
| ||
|
|
| 1154CL |
|
|
|
|
|
|
| ||
|
|
|
|
|
| 1122WH |
|
|
|
| ||
|
| 1113CDNM |
|
|
|
|
|
|
|
| ||
|
|
| 1154CD |
|
|
|
|
|
|
| ||
|
|
|
|
|
| 1123WH |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Features
1.Housing: 0.026” galvanized steel. UL listed for direct contact with thermal insulation. AirSeal® housing minimizes air leakage to less than 2 CFM at 1.57 PSF, which complies with Model Energy Code (Section 602.3.3) and the Washington State Energy Code (Section 502.4) and reduces heat loss and condensation in ceiling. Access door for inspection of junction box.
2.Mounting Frame: 0.036 (#20 ga.) galvanized steel. Accommodates all ceilings up to 1” thick. 3/8” deep integral lip. Four slots are positioned 90° apart to simplify alignment.
3.Junction Box: 2” X 4” X 4”: 0.063” (#14 ga.) galvanized steel. UL listed for maximum of 6 No. 12 ga., 90° C through branch circuit conductors. Quick release “L” shaped cover for outside access to wiring. Access door inside of housing allows easy inspection of wiring without removal of housing. Integral cable clamps permit attachment of nonmetallic Romex® or armored cable without the need for additional connectors.
4.Mounting Bars: 0.059” (#16 ga.) galvanized steel. 13” long bars extend to 27”, rotatable and lockable, with integral
5.Socket Housing: Impact extruded aluminum or galvanized steel.
6.Socket: Porcelain medium base; nickel plated screw shell.
7.Thermal Protector: Meets NEC and UL requirements. Located inside housing.
Options & Accessories
Mounting Bars: 1976 - 13” set of (4).
Labels
UL Type I.C. (Suitable for Damp Locations);
Complies with Air Leakage Requirements as stated in the Model Energy Code, California Title 24 and the Washington State Energy Code.
AirSeal® is a registered trademark of Lightolier
Romex® is a registered trademark of General Cable Industries Inc.
US Patent Numbers: 5,045,985; 4,751,624
Job Information | Type: |
|
|
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte companywww.lightolier.com 631 Airport Road, Fall River, MA 02720 • (508)
© 2006 Genlyte Group LLC • D0906