Samsung AQ18DWANMID, AQ18DWAUMG, AS24DWANMID, AS18DWAMID Operation Ranges, Technical Specifications

Page 32

OPERATION RANGES

The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.

MODE

OPERATING CONDITIONS

IF OUT OF CONDITIONS

 

Indoor temp: 16°C~32°C

- A safety device will stop continuously the

COOL

Indoor humidity: below 80%

system functioning;

 

- Condensation may occur on the indoor unit

 

 

Outdoor temp: 15°C~54°C

with risk to have either water blow off or drops

 

 

on the floor;

HEAT

Indoor temp: below 27°C

- A safety device will stop continuously the

Outdoor temp: -5°C~24°C

system functioning;

 

 

Indoor temp: 16°C~32°C

- A safety device will stop continuously the

DRY

Indoor humidity: below 80%

system functioning;

 

- Condensation may occur on the indoor unit

 

 

Outdoor temp: 15°C~54°C

with risk to have either water blow off or drops

 

 

on the floor;

POWER SUPPLY

Single phase rated voltage

220V-240V~50Hz

minimum and maximum limit

198V min.-264V max.

 

Any damage occurs out of condition specified cannot be covered by product warranty.

If the system works continuosly outside of conditions, its performace and reliability will be compromised.

TECHNICAL SPECIFICATIONS

MODEL

 

AQ18DWAUMG

AQ24DWAUMG

AS18DWAUMG

AS24DWAUMG

 

 

 

 

 

 

 

 

 

 

 

STANDARD

 

ISO

SASO

ISO

SASO

ISO

SASO

ISO

SASO

 

 

 

 

 

 

 

 

 

 

 

 

COOL

18000

3750

24000

5000

18000

3750

24000

5000

CAPACITY

BTU/h

kcal/h

BTU/h

kcal/h

BTU/h

kcal/h

BTU/h

kcal/h

 

 

HEAT

20000

4800

24000

6000

-

-

-

-

 

 

BTU/h

kcal/h

BTU/h

kcal/h

 

 

 

 

 

 

 

SOURCE

 

 

220V~,60Hz

220V~,60Hz

220V~,60Hz

220V~,60Hz

CURRENT

COOL

9.0A

10.5A

12.0A

13.5A

9.0A

10.5A

12.0A

13.5A

HEAT

8.0A

9.0A

12.0A

12.0A

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

POWER

COOL

1894W

2250W

2600W

2900W

1894W

2250W

2600W

2900W

CONSUMPTION

HEAT

1800W

1900W

2600W

2600W

-

-

-

-

 

 

 

 

 

 

 

 

 

 

REFRIGERANT

KIND

R22

R22

R22

R22

 

 

 

 

 

 

 

 

 

 

QUANTITY

1140g

1350g

1200g

1250g

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL

9.5

6.6

9.2

6.8

9.5

6.6

9.2

6.8

EER

BTU/wh

BTU/wh

BTU/wh

BTU/wh

BTU/wh

BTU/wh

BTU/wh

BTU/wh

 

 

HEAT

11.11

10.0

9.2

9.0

-

-

-

-

 

 

BTU/wh

BTU/wh

BTU/wh

BTU/wh

 

 

 

 

 

 

 

 

INDOOR

DB(C/H)

27°C/20°C

29°C/21°C

27°C/20°C

29°C/21°C

27°C/20°C

29°C/21°C

27°C/20°C

29°C/21°C

TEMPERATURE

WB(C/H)

19°C/ -

19°C/ -

19°C/ -

19°C/ -

19°C/ -

19°C/ -

19°C/ -

19°C/ -

OUTDOOR

DB(C/H)

35°C/7°C

46°C/7°C

35°C/7°C

46°C/7°C

35°C/7°C

46°C/7°C

35°C/7°C

46°C/7°C

 

 

WB(C/H)

24°C/6°C

24°C/6°C

24°C/6°C

24°C/6°C

24°C/6°C

24°C/6°C

24°C/6°C

24°C/6°C

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR

NET

13

13

13

13

 

 

 

 

 

 

WEIGHT

GROSS

16

16

16

16

 

 

 

 

 

 

 

 

 

 

OUTDOOR

NET

39

39

56

56

 

 

 

 

 

 

 

 

GROSS

43

43

58

58

 

 

 

 

 

 

 

 

 

 

 

appendix _33

Montblanc2_UMG_29051A_IB_E.indd 33

2008-1-22 13:35:31

Image 32
Contents Cool Summer Offer Cost Efficient SystemLook for Everywhere Only a series modelSevere Warning Signs Safety informationSafety Information Use an exclusive power source for the air conditioner Ensure no water gets into the air conditioner Potential risk of personal injury or burn Make sure there are no obstacles under the indoor unit Contents Using Advanced Functions Viewing your air conditioner before use Checking the Indoor Unit and Digital DisplayMain parts Indoor unit digital displayPower button and Room temperature sensor Removing the Front PanelChecking the Outdoor Unit Air outlet Air intake rear sideChecking the Remote Control Remote control display Using the remote controlInstalling the batteries Slide cover down to Install two AAA Open BatteriesSelecting Operation Mode Operating basic functionTurning the AIR Conditioner on and OFF AutoCool Dry Fan Heat For AQA model Horizontal air flow Adjusting the AIR Flow DirectionVertical air flow To deactivate Turbo function Using advanced functionsUsing the Turbo Function To deactivate the On timer Setting the TimerOn timer To deactivate the Off timer Setting TimerOff timer Combining On timer and Off timer To deactivate the timer combinationOn timer is shorter than Off timer On timer is longer than Off timerMode Temperature changes in mode To deactivate modeWaking up from mode Cool modeUsing the Function only a Series Model Using the Energy Saving Function To deactivate the Energy saving functionUsing the Evaporator Clean Function Autoheat, Heat, Fan mode approximately 15 minutesCleaning and maintaining the air conditioner Cleaning the ExteriorCleaning the Filter Air filter DNA filter Deodorizing filter Replacing the FilterMaintaining Your AIR Conditioner Troubleshooting AppendixTechnical Specifications Operation RangesQuestions or COMMENTS? Air Conditioner