Samsung SVR960NRT/SSC manual Terminal Name Signal Level Type

Page 5

CONTROLS AND INDICATORS

CONNECTORS

FRONT SIDE

REC LOCK lamp

Recording display

Reserve timer recording

Alarm recording display

• Lights during

display

• Lights during alarm

• Lights during record

recording.

• Lights after programming

recording and flickers

locking mode.

 

timer recording.

upon completion of

 

 

 

recording.

Tape presence and

operation display

REC/PLAY Time mode display.

RECLOCK

REC

C.MEMO

 

 

 

 

 

A.MEMO

H

HIGH

FAULT T-END

HOUR

PICTURE

REAR SIDE

EXTERNAL EQUIPMENT TERMINAL

1

ALARM IN

 

2

ALARM OUT

3

ALARM RESET

4

ERROR OUT

5 TRIGGER OUT

6

TAPE END OUT

7

SERIES OUT

8

GND

 

9

SERIES IN

10 1 SHOT RECIN

 

1

2

 

3

4

 

5

6

7

8

9

10

IN

RS-232C

 

IN OUT

OUT

AUDIO

VIDEO

CONFIGUR-

ATION

HIGH PICTURE

Tape End display

Lights when VCR reaches end of tape.

Power failure return

Counter display

Operating hour display.

Alarm/Counter memory

display. " "

Alarm/Counter Memory display

• Counter Memory:

POWER PLUG SLOT

VIDEO IN/OUTPUT JACK

AUDIO IN/OUTPUT JACK (BNC TYPE) (RCA TYPE)

Lights during high picture mode.

display

Flashes upon return of AC power.

Pressing any button turns off.

C. MEMO.

• Alarm Memory:

A. MEMO.

• Operating hour

display: HOUR.

EXTERNAL EQUIPMENT TERMINAL INFORMATION

 

 

 

 

 

 

 

GND

 

 

1

2

3

4

5

6

7

8

9

10

DISPLAY OF OPERATING CONDITIONS

Play back display

Display other than playback

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Playback

Rotates clockwise

Recording

Rotates clockwise

 

 

 

 

 

REC

 

 

 

 

 

 

 

 

 

 

 

 

 

Still

Blinking

Pause

Blinking

 

 

 

 

 

REC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slow Playback

Blinking and rotating clockwise

Timer Recording

Rotates clockwise

REC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Forward Search

Rotates rapidly clockwise

Alarm Recording

Rotates clockwise

 

 

 

 

REC

 

 

 

 

 

 

 

 

 

 

 

 

Reverse Search

Rotates rapidly counterclockwise

Rewinding

Rotates rapidly counterclockwise

 

 

 

 

 

 

 

 

 

 

Reverse Playback

Rotates counterclockwise

Fast Forwarding

Rotates rapidly clockwise

 

 

 

 

 

 

 

 

 

 

Reverse Slow

Blinking and rotates slowly

 

 

 

 

 

 

 

 

Playback

counterclockwise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TERMINAL NAME

 

 

 

 

SIGNAL LEVEL

TYPE

 

 

 

 

 

 

 

 

 

 

 

1

ALARM IN

 

VIH

 

 

 

 

VIH

: 4 ~ 5V

INPUT

 

 

 

VIL

 

 

VIL

: 0 ~ 0.6 V

 

 

 

 

 

 

 

 

 

T

 

 

 

T

: More than 0.5 second

 

2

 

 

VIH

 

VIL

VIH

: 4 ~ 5V

OUTPUT

 

 

 

ALARM OUT

 

 

 

VIL

: 0 ~ 0.6 V

 

 

 

 

 

 

 

 

 

 

T

 

 

 

T

: Alarm Recording

 

 

 

 

 

 

 

 

VIH

: 4 ~ 5V

 

3

 

 

VIH

 

 

 

 

INPUT

ALARM RESET

 

 

 

VIL

 

 

VIL

: 0 ~ 0.6 V

 

 

 

 

 

 

 

 

 

T

 

 

 

T

: More than 0.5 second

 

 

 

 

 

 

 

 

VIH

: 4 ~ 5V

 

4

ERROR OUT

 

VIH

 

 

 

 

OUTPUT

 

 

 

VIL

 

 

VIL

: 0 ~ 0.6 V

 

 

 

 

 

 

 

 

 

T

 

 

 

T

:

 

 

 

 

 

 

 

 

VIH

: 4 ~ 5V

 

5

TRIGGER OUT

 

VIH

 

 

 

 

OUTPUT

 

 

 

VIL

 

 

VIL

: 0 ~ 0.6 V

 

 

 

 

 

 

 

 

 

T

 

 

 

T

: More than 8m sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIH

: 4 ~ 5V

 

6

 

 

VIH

 

 

 

 

OUTPUT

TAPE END OUT

 

 

 

VIL

 

 

VIL

: 0 ~ 0.6 V

 

 

 

 

 

 

 

 

 

T

 

 

 

T

: During input any button

 

 

 

 

 

 

 

 

VIH

: 4 ~ 5V

 

7

 

 

VIH

 

 

 

 

OUTPUT

SERIES OUT

 

 

 

VIL

 

 

VIL

: 0 ~ 0.6 V

 

 

 

 

 

 

 

 

 

T

 

 

 

T

: More than 1 second

 

8

GND

 

 

 

 

 

 

 

0V

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIH

: 4 ~ 5V

 

9

SERIES IN

 

VIH

 

 

 

 

INPUT

 

 

 

VIL

 

 

VIL

: 0 ~ 0.6 V

 

 

 

 

 

 

 

 

 

T

 

 

 

T

: More than 0.5 second

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIH

: 4 ~ 5V

 

10 1 SHOT REC IN

 

VIH

 

VIL

 

 

INPUT

 

 

 

 

 

VIL

: 0 ~ 0.6 V

 

 

 

 

T

 

 

 

T

: More than 0.5 second

 

 

 

 

 

 

 

 

 

 

 

7

8

Image 5
Contents SVR-960NRT Spill liquid of any kind on the unit Important SafeguardsContents Accessory Controls and IndicatorsTerminal Name Signal Level Type Turn on the power of the monitor SET UPMake a connection between the monitor and this unit Connect the CCD camera to this unitTo select a menu item HOW to SET MenuPress the Shift ButtonHOW to SET the Current Time Setting Current TimeSetting Display and Alarm REC Setting MenuTo set Alarm REC in L6H mode for 5 minutes To turn the time on or offSetting REC Mode and VCR Mode Setting Program REC Setting MENU1Checking Power Failure Time and Date You can set up to 10 programs a weekNormal OperationPlayback During stopTo hear the normal sound When viewing special playback picturesVarious Playbacks Various Playbackcont When rewinding the tapePlayback picture Still pictureRecord Locking Operations when the tape ends during recordingCondensation LockBasic Recording Reset button Alarm RecordingWhen pressing the Reset button Series RecordingAlarm Functions High Picture Connecting Operating Description MethodConvenient Functions Camera TV MonitorMethod of Connection Alarm OUTSVR-960NRT REC TriggerTroubleshooting MaintenanceWhen the screen does not show a good picture Insert the cleaning tape Into your video and pressREC Lock switch in the OFF, and then press TROUBLESHOOTINGCONT.DIf there is any other problem contact service center Button Playback picture is noisyDaily Checks Recording Type Specifications