Crimestopper Security Products CS-882 OEM operating instructions Installation Mode a Most Vehicles

Page 6

INSTALLATION MODE “A” (Most Vehicles)

MODE A is the default mode and is used for most vehicles.

This mode requires 4-Wires to be connected for proper operation: Yellow/Black and Blue/Black connect to the

(+)12V solenoid lock & unlock wires. Green/White and Red/ White connect to the factory door lock switch. The polarity (+/-) of the Green/White and Red/White wires can be changed by using the slide switch on the top of the CS-882OEM module. See Diagrams below for standard MODE “A” installation.

YELLOW / BLACK

 

 

BLUE / BLACK

 

GREEN / WHITE

 

 

RED / WHITE

 

L

+ / - LOCK SWITCH WIRE *

 

FACTORY

 

 

POWER

(+) LOCK / MOTOR WIRE

U

LOCK

 

RELAYS

(+) UNLOCK / MOTOR WIRE

 

+ / - UNLOCK SWITCH WIRE *

LOCK

 

 

 

SWITCH

(*Programmable for POS/NEG validation)

 

The slide-switch on the top of the module determines the polarity of Green/White and Red/White “Validate” Wires. Connecting the Green/White and Red/White “Validation” wires to the factory door lock switch prevents an intruder or thief from arming or disarming the system by pressing the lock/unlock button on the vehicle door panel.

(TOP EDGE OF 882 MODULE)

POSITIVE VALIDATION INPUTS

(TOP EDGE OF 882 MODULE)

NEGATIVE VALIDATION INPUTS

6

Image 6
Contents CS-882 OEM Table of Contents Installation Precautions & WarningsComponent Mounting RED Wire +12V Power Input 15 amp fuse Wiring Black Wire System Chassis Ground Orange Wire Negative Starter Disable Armed outputYellow Wire +12 Volts Ignition Switched Page Installation Mode a Most Vehicles Mode a is the default mode and is used for most vehiclesInstallation Mode B Mode B Wiring Diagram Resistors and Diodes are includedViolet Door Warning Delay Programmable OptionsFlashing Lights SIREN/HORN Confirmation Panic ModeOption Reset Passive ArmingOperating Instructions Operating Insructions Valet ModePanic Mode Programmable Option Factory Trunk Release Sensing