Crimestopper Security Products SP-500 manual Diesel Glow Plug Delay, Programmable Options

Page 19

DIESEL GLOW PLUG DELAY

This feature provides a solution for diesel vehicles without having to connect to the Glow Plug-“Wait to Start Circuit” input. This may be due to a variety of reasons for example: If your vehicle does not have a viable “Wait to Start Circuit” or you cannot locate and identify the circuit. You can choose from a selection of “pre-cranking” delay times. Once this mode is activated, the system will NO LONGER monitor the PINK glow plug input wire and will use a delay setting chosen by the installer in the option chart.

NOTES: This feature is OFF by default and must be programmed before use. Once this feature is turned ON, the Pink Glow plug input wire is not used. The Remote start unit will always wait the programmed time before cranking EVEN IF the glow plugs warm up first. There are 3 different Delay times available for use: 10, 20, or 30 seconds. SEE PROGRAMMING OPTION CHART, next section.

HOW TO USE THIS FEATURE:

1.See the “Programmable Options” next section and change Option #22 from "Monitor Glow Plug Light" to one of the delayed time values. (Default setting is to always monitor the PINK Glow Plug input wire.)

2.Once this option has changed the system will wait for the selected time before cranking the engine.

PROGRAMMABLE OPTIONS

You can program multiple options in one session if you start with the lowest option and continue on to higher options [if needed] without repeating steps #1-3 below. For example, you can follow the programming steps to change Option #2 to “OFF” by pressing the lock button on the remote, then you can continue pressing the program button additional times to get to a high number option and change the setting without having to repeat Steps 1-5. You can only go from low to higher option numbers in one session.

To Engage Option Programming:

1.Open Hood (ground blue hood pin wire if no hood pin switch is installed)

2.Turn Key to the ON position

3.Press program / valet button 5 times, after a few seconds the unit will flash the lights 5 times.

4.Push the valet/program button [again] the number of times that corresponds to the option number desired (1 thru 30). You must get a light flash after each button press. See chart on next page for option list.

5.When you reach the desired programming level, Press button #1, #2 #3 or #4 to change the option.

6.Turn Ignition OFF, Close hood (or unground blue hood pin wire) and check for changed features. Change each option individually repeating #1-5.

19

Image 19
Contents Disclaimer IntroductionREV PR PRE-INSTALLATION Considerations Table of ContentsComponent Mounting Windshield Antenna DiagramBrown + Siren Output Wiring 9-PIN ConnectorGreen Mode a Start Activation Input Green Mode B Optional Turbo Timer InputNegative Auxilary Output +12V Constant GREEN/RED Starter Disable Orange Negative Starter Disable/Anti-Grind OutputWiring 6-PIN High Current Connector Wiring 3-PIN ConnectorWiring 5-PIN Connector Trigger Inputs White +12V Brake Reset Wiring 5-PIN ConnectorBLUE/ORANGE Starter VIOLET/WHITE AUX Wire 4 PIN Output ConnectorYELLOW/BLACK OEM Rearm Output BLUE/ORANGE Starter #3Shock Sensor Wiring 4-PIN Shock Sensor 22 Gauge wiresPower Door Locks Wiring & System Types Negative Trigger Doorlock Wiring Door Lock WiringNegative Trigger Door Locks Separate DRIVER’S Door Unlock WiringTachless Adjustment Tachless ModeImportant Notes Tach Programming Tach Mode & Tach Finder FeatureTach Finder Feature Tach FinderHOW to USE this Feature Timed Crank ModeProgrammable Options Diesel Glow Plug DelayTo Engage Option Programming Option Programming Table Engine Monitoring Programmable Option DescriptionsAUTOLOCK/UNLOCK W/IGNITION Siren Chirps with Remote Start Activation Programmable OptionsPassive Locks Parking Lights on with DisarmSiren Chirps with ARM/DISARM Door LOCK/UNLOCK Pulse TimeDouble Unlock Pulse Lock DURING/AFTER Remote StartULTRA-SMART Tachless Voltage Adjustment Diesel Glow Plug DelayFactory Horn Chirps / Pulses Aux #4 Time control 1 sec. to 255 sec. Default = 12 seconds Programmable Option ResetTurbo Timer Mode Option Reset Restore to Default Remote Programming Diagram Vehicle Control Vehicle OperationVehcle Notes Remote Start Diagnostics Alarm Trigger DiagnosticsParking Light Flashes = Manual Transmission Mode Error Securing Jumpers Jumper PIN DiagramStart IGN ACC Jumper Wiring DiagramSee Option # 7 on Data Port Diagram