Desa 70, 90, 30 owner manual Removing Burner Head, 150,000 BTU/Hr Model

Page 17

Nozzle

(150,000 BTU/Hr Model)

1.Remove upper shell (see page 10).

2.Remove fan (see page 19).

3.Remove spark plug wire from spark plug.

4.Remove spark plug from burner head using 13/16" open-end wrench.

5.Loosen flare nut using 3/4" open-end wrench. Push fuel tube down.

6.Remove air line hose from burner head.

7.Remove three screws using 5/16" nut-driver and remove burner head from combustion chamber.

8.Place burner head into vise and lightly tighten.

9.Carefully remove nozzle from burner head using 5/8" socket wrench (see Figure 30).

10.Blow compressed air thru face of nozzle. This will free any dirt in nozzle area.

11.Inspect nozzle seal for damage.

12.Replace nozzle into burner head and tighten firmly

(80-110 inch-pounds/9.1-

12.4 n-m).

13.Attach burner head to combustion chamber.

14.Install spark plug in burner head.

15.Attach spark plug wire to spark plug.

16.Attach fuel tube and airline hose to burner head. Attach flare nut until nut seats against fuel tube and fitting. Tighten 1/4 turn more using 3/4" open-end wrench (100-130 inch- pounds/11.3-14.7 n-m).

17.Replace fan (see page 19).

18.Replace fan guard and upper shell.

Combustion

Chamber

 

Spark Plug

Burner Head

Wire

Screw

Spark

Plug

Air Line Hose

Flare Nut

Fuel Tube

Figure 29 - Removing Burner Head, 150,000 BTU/Hr Model

Nozzle

Face

Nozzle

Seal

Nozzle

Burner

Head

Figure 30 - Removing Nozzle, 150,000 BTU/Hr Model

17

099606

Image 17
Contents ReDDY HeaTeR Contents Carbon monoxide poisoning may lead to death Safety InformationProduct Identification Tools Needed Unpacking AssemblyFuels TheoryOperation To Start Heater Ventilation OperationTo Restart Heater Operation Storage Preventative Maintenance ScheduleTo Stop Heater How Often How To TROUBLE- ShootingFuel Filter Service ProceduresUpper Shell Removal Remove side cover screws using 5/16 nut-driver Spark Plug Removal, 30,000 BTU/Hr Model Spark PlugSpark Plug Removal, 70/90/150,000 BTU/Hr Models Air Output, Air Intake, and Lint Filters Pump Pressure AdjustmentRemoving Air and Fuel Line Hoses, 30,000 BTU/Hr Model NozzleRemoving Burner Head, 70/90,000 BTU/Hr Models Removing Burner Head, 150,000 BTU/Hr Model Rotor Location, 30/70,000 BTU/Hr Models Pump RotorFan Specifications30,000 BTU/Hr Parts BreakdownKEY Part Number Description QTY Parts List70,000 BTU/Hr Burner Head AssemblyFHPF3-2C 90,000 BTU/Hr M10908-2 Screw, #6-32 x 3/8 150,000 BTU/Hr IllustratedNPC-4C Wheels and Handles for Wiring Diagram, 30,000 BTU/Hr Wiring DiagramsAccessories 099606 Certificate of General Equipment Limited 90 DAY Warranty Warranty and Repair Service