Desa 90 owner manual Pump Rotor, Rotor Location, 30/70,000 BTU/Hr Models

Page 18

Pump Rotor

(Procedure if rotor is binding)

1.Remove upper shell (see page 10).

2.Remove filter end cover screws using 5/16" nut- driver.

3.Remove filter end cover and air filters.

4.Remove pump plate screws using 5/16" nut- driver.

5.Remove pump plate.

6.Remove rotor, insert, and blades.

7.Check for debris in pump. If debris is found, blow out with compressed air.

8.Install insert and rotor.

9.Check gap on rotor. Adjust to .003"/.004" (.076/.101 mm) if needed (see Figure 33).

Note: Rotate rotor one full turn to insure the gap is

.003"/.004" (.076/.101 mm) at tightest position. Adjust if needed.

10.Install blades, pump plate, air filters, and filter end cover.

11.Replace fan guard and upper shell.

12.Adjust pump pressure (see page 14).

Note: If rotor is still binding, proceed as follows.

13.Perform steps 1 thru 6 above.

14.Place fine grade sandpaper (600 grit) on flat surface. Sand rotor lightly in “figure 8” motion four times (see Figure 34).

15.Reinstall insert and rotor.

16.Perform steps 10 thru 12 above.

18

Blade

Air

 

Pump

Intake

 

 

Plate

 

 

Filter

 

 

 

 

 

 

 

 

Filter End

 

 

 

 

Cover

 

 

 

 

 

Fan Guard

 

 

 

 

(90,000 BTU/Hr

 

Insert

 

 

Model Shown)

 

 

 

 

 

Rotor

 

 

 

 

Air Output

 

 

 

50 ROTOR

Filter

 

 

 

PFA/P 056

 

 

 

Figure 31 - Rotor Location, 30/70,000 BTU/Hr Models

 

Blade

Pump

 

 

 

Plate

 

 

 

 

 

 

 

 

 

Air

 

 

 

 

Intake

 

 

 

 

Filter

 

 

 

 

Filter End

 

 

 

Cover

Fan Guard

 

 

 

 

(90,000 BTU/Hr

Insert

 

 

Model Shown)

 

 

 

 

Rotor

 

 

 

 

Air

 

 

 

150 ROTOR

Output

 

 

 

PFA/P 059

 

 

 

 

Filter

 

 

 

Figure 32 - Rotor Location, 90/150,000 BTU/Hr Models

Gap Adjusting

Screw

 

.003"/.004"

 

(.076/.101 mm) Gap

 

Measured With

 

Feeler Gauge

 

Sandpaper

Blade

Rotor

 

Gap

 

Adjusting

 

Screw

 

Figure 33 - Gap Adjusting

 

Screw Locations

Figure 34 - Sanding Rotor

099606

Image 18
Contents ReDDY HeaTeR Contents Safety Information Carbon monoxide poisoning may lead to deathProduct Identification Unpacking Assembly Tools NeededTheory OperationFuels Ventilation Operation To Start HeaterOperation Storage Preventative Maintenance Schedule To Stop HeaterTo Restart Heater TROUBLE- Shooting How Often How ToService Procedures Upper Shell RemovalFuel Filter Remove side cover screws using 5/16 nut-driver Spark Plug Spark Plug Removal, 30,000 BTU/Hr ModelSpark Plug Removal, 70/90/150,000 BTU/Hr Models Pump Pressure Adjustment Air Output, Air Intake, and Lint FiltersNozzle Removing Air and Fuel Line Hoses, 30,000 BTU/Hr ModelRemoving Burner Head, 70/90,000 BTU/Hr Models Removing Burner Head, 150,000 BTU/Hr Model Pump Rotor Rotor Location, 30/70,000 BTU/Hr ModelsSpecifications FanParts Breakdown 30,000 BTU/HrParts List KEY Part Number Description QTYBurner Head Assembly 70,000 BTU/HrFHPF3-2C 90,000 BTU/Hr M10908-2 Screw, #6-32 x 3/8 Illustrated 150,000 BTU/HrNPC-4C Wheels and Handles for Wiring Diagrams Wiring Diagram, 30,000 BTU/HrAccessories 099606 Warranty and Repair Service Certificate of General Equipment Limited 90 DAY Warranty
Related manuals
Manual 40 pages 14.56 Kb