Samsung AR09HSSDPWKNEE manual Connecting the power and communication cables assembly cable

Page 11

Step 2.3 Connecting the power and communication cables (assembly cable)

When performing electrical and earthing works, be sure to comply with the 'technical standards of electrical installations' and the 'wiring regulations' in the local regulations.

Tighten the terminal block screw to 1.2-1.8 N•m (12- 18 kgf•cm).

 

 

Control box

Before

 

 

 

connecting

 

 

 

Correct

Upside down

Damaged

Non-circular

After

 

 

 

connecting

 

 

 

Correct

Correct

Upside down

Non-fitted

(Front view)

(Side view)

<Circular terminal>

1(L)2(N)

F1 F2

 

Fasten the screws for the wire holders.

 

 

 

 

Model

AR09HSSDPWK/EE

 

AR12HSSDPWK/EE

 

 

 

 

 

 

Power cable

3G X 1.5 mm²,

 

(Outdoor unit)

H07RN-F

 

 

 

Installation

Outdoor-to-indoor

3G X 1.0 mm²,

power cable

H07RN-F

 

 

 

 

 

Communication

2 X 0.75 mm²,

 

cable

H05RN-F

 

 

 

 

Type GL

16A

 

 

 

10English

NOTE

Each wire is labelled with the corresponding terminal number.

Use shield cable (Category 5; less than 50pF/m) for noisy environmental site.

Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord. (Code designation IEC: 60245 IEC 66/ CENELEC: H07RN-F, IEC: 60245 IEC 57/CENELEC: H05RN-F)

Power & Communication cable shall not exceed 30m.

CAUTION

For the terminal block wiring, use a wire with a ring terminal socket only. Regular wires without a ring terminal socket may become a hazard due to overheating of the electrical contact during installation.

If you need to extend the pipe, be sure to extend the cable too. The maximum length of each of the cable and pipe used should not exceed 15 metres.

Do not connect two or more different cables to extend the length. This connection may cause fire.

Each circular terminal must match the size of its corresponding screw in the terminal block.

After connecting the cables, make sure that terminal numbers on the indoor and outdoor units match.

Ensure that power and communication cables are separated, they must not be in the same cable.

WARNING

Connect the wires firmly so that wires cannot be pulled out easily. (If they are loose, it could cause burn-out of the wires.)

A3050 EE Better IM_DB68-06139A-00_EN_A5.indd 10

2016/5/6 10:32:02

Image 11
Contents A3050 EE Better IMDB68-06139A-00ENA5.indd 2016/5/6 Air conditioner Contents General information Safety Information on InstallationPower supply line, fuse, or circuit breaker Minimum clearances for the outdoor unit Choosing the installation locationOverview of installation location requirements PreparationAccessories Checking and preparing accessories and toolsTools Drilling a hole through the wallDrill the hole Be sure to drill only one hole Taping the pipes, cables, and drain hoseDisassembling the cover panel Indoor Unit InstallationConnecting the power and communication cables assembly cable Prepare a compressor and the following tools Optional Extending the power cableOptional Extending the drain hose Installing and connecting the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a gypsum board 10 Fixing the installation plateWhen fixing the indoor unit on a wall When fixing the indoor unit on a window frame12 Assembling the cover panel 11 Fixing the indoor unit to the installation plateOptional Fixing the outdoor unit to a wall with a rack Outdoor Unit InstallationFixing the outdoor unit in place Evacuating the air Adding refrigerant Installation Performing the gas leak tests Installation InspectionRunning the Smart Install mode LED Pumping down for removing the product Performing final check and trial operationPumping down refrigerant Description Display Error and Check MethodA3050 EE Better IMDB68-06139A-00ENA5.indd 2016/5/6
Related manuals
Manual 35 pages 32.76 Kb Manual 35 pages 41.66 Kb Manual 35 pages 39.98 Kb Manual 35 pages 42.62 Kb Manual 21 pages 35.09 Kb Manual 21 pages 35.92 Kb Manual 21 pages 45.16 Kb Manual 21 pages 32.84 Kb Manual 25 pages 30.63 Kb Manual 26 pages 17.38 Kb Manual 1 pages 46.73 Kb Manual 35 pages 41.68 Kb Manual 26 pages 26.34 Kb Manual 26 pages 17.72 Kb Manual 26 pages 17.61 Kb Manual 1 pages 30.99 Kb

AR12HSSDPWKNEE, AR09HSSDPWKNEE specifications

The Samsung AR09HSSDPWKNEE and AR12HSSDPWKNEE are part of Samsung's high-efficiency air conditioning lineup, designed to provide superior comfort while ensuring energy savings. These models are particularly popular for their advanced technologies and user-friendly features, making them ideal for residential and small commercial spaces.

One of the standout features of both models is the Digital Inverter Technology. This innovative technology maintains the desired temperature without the constant on-and-off cycling typical of conventional air conditioning units. As a result, these units provide a more stable cooling experience, while significantly reducing energy consumption. The Digital Inverter also helps in minimizing wear and tear, leading to increased lifespan and reduced maintenance needs.

The AR09HSSDPWKNEE and AR12HSSDPWKNEE are equipped with the Triple Protector Plus technology, which offers enhanced durability and reliability. This feature protects the compressor and provides safety against voltage fluctuations. Additionally, the units are designed to operate in extreme weather conditions, ensuring consistent performance even in high temperatures or low-voltage situations.

Another notable feature is the Fast Cooling mode. This allows the air conditioner to cool the room quickly to the desired temperature, making it incredibly convenient during hot weather. The units also come with a Quiet Mode, which minimizes noise levels, making them suitable for bedrooms or quiet spaces.

Energy efficiency is a critical characteristic of these models. With high energy efficiency ratings, they help in lowering electricity bills while being environmentally friendly. The units are also designed to be eco-conscious, with R32 refrigerant, which has a lower global warming potential than traditional refrigerants.

In terms of user interface, the AR09HSSDPWKNEE and AR12HSSDPWKNEE come with a sleek and intuitive remote control, allowing users to manage settings conveniently from anywhere in the room. Additionally, they feature a filtration system that improves indoor air quality by removing dust and allergens, creating a healthier living environment.

Overall, the Samsung AR09HSSDPWKNEE and AR12HSSDPWKNEE air conditioners combine cutting-edge technology, efficiency, and user-friendly features, making them an excellent choice for anyone looking to enhance their home’s comfort while keeping energy costs in check.