Samsung AR09HSSDPWKNEE, AR12HSSDPWKNEE manual Display Error and Check Method, Description

Page 25

Installation

Step 4.4 Display Error and Check Method

Indoor Display Error and Check Method

 

ERROR MODE

 

 

Indoor

 

 

Outdoor

 

DESCRIPTION

 

 

 

 

 

 

 

YEL

GRN

 

RED

 

 

 

 

 

 

 

 

Normal operation

 

 

 

Power on reset(1sec.)

 

 

 

Power off / VDD NG

dF

 

 

When dF shows on the 88 segment of the Indoor unit, this means that the system is in defrost mode.

 

 

 

 

 

 

Note that during this operation period, system performance will be reduced.

E101

 

 

Communcation error (IndoorOutdoor)

E102

 

 

E121

 

 

 

 

 

Indoor room temperature sensor error

 

 

 

 

 

 

 

E122

 

 

 

 

 

Evap-In temperature sensor error

 

 

 

 

 

 

 

E154

 

 

 

 

 

Fan error (Indoor)

 

 

 

 

 

 

 

E162

 

 

 

 

 

EEPROM error (Indoor)

 

 

 

 

 

 

 

E163

 

 

 

 

 

Option setting error

 

 

 

 

 

 

 

E203

 

 

1min. Time out Communcation (Inv micomMain micom)

E221

 

 

Outdoor temperature sensor error

E231

 

 

Outdoor Coil temperature sensor error

E251

 

 

Discharge temperature sensor error

E416

 

 

Discharge over temperature

E422

 

 

EEV or Valve Close error-Self diagnosis

E440/

 

 

Out of the Limit of the operation(Outdoor temperature)

E441

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E458

 

 

Fan error (Outdoor)

E461

 

 

Compressor starting error

E462

 

 

Compressor trip error / PFC over current

E464

 

 

IPM over current (O.C)

E465

 

 

Compressor V-limit error

E466

 

 

DC-Link voltage under/over error

E467

 

 

Compressor rotation error(comp. wire missing error)

E468

 

 

Current sensor error

E469

 

 

DC-Link voltage sensor error

E470

 

 

EEPROM error (Outdoor)

E471

 

 

OTP error

E472

 

 

AC line zero cross signal error

E474

 

 

Heat-Sink sensor error

E483

 

 

H/W DC-Link over

E484

 

 

PFC over load

E485

 

 

Input current sensor error

E500

 

 

Heat-Sink overheat error

E554

 

 

Gas-Leak error

E556

 

 

Capacity miss match error

24English

A3050 EE Better IM_DB68-06139A-00_EN_A5.indd 24

2016/5/6 10:32:09

Image 25
Contents A3050 EE Better IMDB68-06139A-00ENA5.indd 2016/5/6 Air conditioner Contents General information Safety Information on InstallationPower supply line, fuse, or circuit breaker Overview of installation location requirements Choosing the installation locationPreparation Minimum clearances for the outdoor unitAccessories Checking and preparing accessories and toolsTools Drilling a hole through the wallDrill the hole Be sure to drill only one hole Taping the pipes, cables, and drain hoseDisassembling the cover panel Indoor Unit InstallationConnecting the power and communication cables assembly cable Prepare a compressor and the following tools Optional Extending the power cableOptional Extending the drain hose Installing and connecting the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe When fixing the indoor unit on a wall 10 Fixing the installation plateWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum board12 Assembling the cover panel 11 Fixing the indoor unit to the installation plateFixing the outdoor unit in place Outdoor Unit InstallationOptional Fixing the outdoor unit to a wall with a rack Evacuating the air Adding refrigerant Installation Running the Smart Install mode Installation InspectionPerforming the gas leak tests LED Pumping down refrigerant Performing final check and trial operationPumping down for removing the product Description Display Error and Check MethodA3050 EE Better IMDB68-06139A-00ENA5.indd 2016/5/6
Related manuals
Manual 35 pages 32.76 Kb Manual 35 pages 41.66 Kb Manual 35 pages 39.98 Kb Manual 35 pages 42.62 Kb Manual 21 pages 35.09 Kb Manual 21 pages 35.92 Kb Manual 21 pages 45.16 Kb Manual 21 pages 32.84 Kb Manual 25 pages 30.63 Kb Manual 26 pages 17.38 Kb Manual 1 pages 46.73 Kb Manual 35 pages 41.68 Kb Manual 26 pages 26.34 Kb Manual 26 pages 17.72 Kb Manual 26 pages 17.61 Kb Manual 1 pages 30.99 Kb

AR12HSSDPWKNEE, AR09HSSDPWKNEE specifications

The Samsung AR09HSSDPWKNEE and AR12HSSDPWKNEE are part of Samsung's high-efficiency air conditioning lineup, designed to provide superior comfort while ensuring energy savings. These models are particularly popular for their advanced technologies and user-friendly features, making them ideal for residential and small commercial spaces.

One of the standout features of both models is the Digital Inverter Technology. This innovative technology maintains the desired temperature without the constant on-and-off cycling typical of conventional air conditioning units. As a result, these units provide a more stable cooling experience, while significantly reducing energy consumption. The Digital Inverter also helps in minimizing wear and tear, leading to increased lifespan and reduced maintenance needs.

The AR09HSSDPWKNEE and AR12HSSDPWKNEE are equipped with the Triple Protector Plus technology, which offers enhanced durability and reliability. This feature protects the compressor and provides safety against voltage fluctuations. Additionally, the units are designed to operate in extreme weather conditions, ensuring consistent performance even in high temperatures or low-voltage situations.

Another notable feature is the Fast Cooling mode. This allows the air conditioner to cool the room quickly to the desired temperature, making it incredibly convenient during hot weather. The units also come with a Quiet Mode, which minimizes noise levels, making them suitable for bedrooms or quiet spaces.

Energy efficiency is a critical characteristic of these models. With high energy efficiency ratings, they help in lowering electricity bills while being environmentally friendly. The units are also designed to be eco-conscious, with R32 refrigerant, which has a lower global warming potential than traditional refrigerants.

In terms of user interface, the AR09HSSDPWKNEE and AR12HSSDPWKNEE come with a sleek and intuitive remote control, allowing users to manage settings conveniently from anywhere in the room. Additionally, they feature a filtration system that improves indoor air quality by removing dust and allergens, creating a healthier living environment.

Overall, the Samsung AR09HSSDPWKNEE and AR12HSSDPWKNEE air conditioners combine cutting-edge technology, efficiency, and user-friendly features, making them an excellent choice for anyone looking to enhance their home’s comfort while keeping energy costs in check.