Step 4.3 Performing final check and trial operation

1Check the following:

Strength of the installation site

Tightness of pipe connection to detect gas leak

Electric wiring connection

Heat-resistant insulation of the pipe

Drainage

Grounding conductor connection

Correct operation (Take the following steps.)

2Press the (Power) button on the remote control to check the following:

The indicator on the indoor unit lights up.

The airflow blade opens and the fan gears up for operation.

3Press the (Mode) button to select Cool or Heat mode. Then take the following sub-steps:

In Cool mode, use the Temperature button to set the set temperature to 16 °C.

In Heat mode, use the Temperature button to set the set temperature to 30 °C.

Check whether, approximately 3 to 5 minutes later, the outdoor unit starts, and a cool or warm air blows out.

After 12 minutes of stationary condition, check the indoor unit air treatment.

4Press the (Air swing) button to check whether the airflow blades work properly.

5Press the (Power) button to stop the trial operation.

Pumping down refrigerant

Pump-down is an operation intended to collect all the system refrigerant in the outdoor unit. This operation must be carried out before disconnecting the refrigerant tubing in order to avoid refrigerant loss to the atmosphere.

1Shut off the liquid valve with the Allen wrench.

2Turn on the air conditioner in cooling with fan operating at high velocity. (Compressor will immediately start, provided 3 minutes have elapsed since the last stop.)

3After 2 minutes of operation, shut the suction valve with the same wrench.

4Turn off the air conditioner and switch mains supply off.

5Disconnect tubing. After disconnection, protect valves and tubing ends from dust.

CAUTION

Compressor damage may occur if the compressor is run at a negative suction pressure.

Pumping down for removing the product

1Hold down the (Power) button on the indoor unit for 5 seconds. Beep sounds immediately to indicate that the product is ready for pump down procedure.

2Let the compressor run for more than 5 minutes.

3Release the valve caps on High and Low pressure side.

4Use L-wrench to close the valve on the high pressure side.

5After approximately 1 minute, close the valve on the low pressure side.

6Stop operation of the air conditioner by pressing the (Power) button on the indoor unit or remote control.

7Disconnect the pipes.

 

1

 

1 minute

Liquid service port

Gas service port

<High pressure>

<Low pressure>

2

Off

Installation

English 23

A3050 EE Better IM_DB68-06139A-00_EN_A5.indd 23

2016/5/6 10:32:09

Image 24
Contents A3050 EE Better IMDB68-06139A-00ENA5.indd 2016/5/6 Air conditioner Contents Safety Information on Installation General informationPower supply line, fuse, or circuit breaker Choosing the installation location Overview of installation location requirementsPreparation Minimum clearances for the outdoor unitChecking and preparing accessories and tools AccessoriesDrilling a hole through the wall ToolsTaping the pipes, cables, and drain hose Drill the hole Be sure to drill only one holeIndoor Unit Installation Disassembling the cover panelConnecting the power and communication cables assembly cable Optional Extending the power cable Prepare a compressor and the following toolsInstalling and connecting the drain hose Optional Extending the drain hoseOptional Changing the direction of the drain hose Shortening or extending the refrigerant pipes assembly pipe 10 Fixing the installation plate When fixing the indoor unit on a wallWhen fixing the indoor unit on a window frame When fixing the indoor unit on a gypsum board11 Fixing the indoor unit to the installation plate 12 Assembling the cover panelOutdoor Unit Installation Fixing the outdoor unit in placeOptional Fixing the outdoor unit to a wall with a rack Evacuating the air Adding refrigerant Installation Installation Inspection Running the Smart Install modePerforming the gas leak tests LED Performing final check and trial operation Pumping down refrigerantPumping down for removing the product Display Error and Check Method DescriptionA3050 EE Better IMDB68-06139A-00ENA5.indd 2016/5/6
Related manuals
Manual 35 pages 32.76 Kb Manual 35 pages 41.66 Kb Manual 35 pages 39.98 Kb Manual 35 pages 42.62 Kb Manual 21 pages 35.09 Kb Manual 21 pages 35.92 Kb Manual 21 pages 45.16 Kb Manual 21 pages 32.84 Kb Manual 25 pages 30.63 Kb Manual 26 pages 17.38 Kb Manual 1 pages 46.73 Kb Manual 35 pages 41.68 Kb Manual 26 pages 26.34 Kb Manual 26 pages 17.72 Kb Manual 26 pages 17.61 Kb Manual 1 pages 30.99 Kb