Operating the Remote Control

Power

Use the

 

Power button to turn the portable air conditioner on and off.

 

 

 

By default when you first use the power button, the unit will begin to

 

 

operate in cooling mode and the front panel will be illuminated in blue.

 

 

The unit will remember the last used mode/settings if you shut down and

 

 

restart.

 

 

 

 

 

Auto-Restart:If power to the unit is interrupted, the air conditioner will

 

 

restart itself in its last used mode/settings once power is restored. The

 

 

compressor will restart after 3 minutes.

 

 

 

 

Cooling Mode

Cooling mode cools and dehumidifies the air. If the ambient temperature

 

 

drops below the temperature you selected, the compressor turns off and

the unit functions with the fan only. When the temperature rises above the temperature you selected, the compressor turns on again. The front panel lights will be blue.

Whether your desired temperature can actually be reached depends on the ambient conditions. The room temperature remaining above the set temperature is normal.

To operate the unit in cooling mode:

1)Make sure the power cord is plugged into a power outlet.

2)Press the Power button on the remote control.

3)Press the Mode button until the cooling indicator is selected.

4)Select the fan speed by using the Speed button.

 

NOTE: The exhaust hose

5) Set the thermostat by using the

Up and

Down buttons. The

 

must be used in Cooling

thermostat is adjustable between 64°F - 90°F in one degree increments.

 

mode in order to cool a room.

You can switch between Fahrenheit and Celsius by pressing the

 

 

 

 

button.

 

 

 

 

 

 

 

 

 

 

 

 

Dehumidifying Mode

During the Dehumidifying mode, the unit will condense water out of the air

and exhaust it through the exhaust hose. The ambient temperature in the

 

 

 

 

room will probably drop by a few degrees while using the Dehumidifying

 

 

mode. The front panel lights will be yellow.

 

 

To operate the unit in dehumidifying mode:

1)Make sure the power cord is plugged into a power outlet.

2)Press the Power button on the remote control.

3)Press the Mode button until the dehumidify indicator is selected.

NOTES: If the room temperature is below 77ºF, the fan will always run on low speed while in the Dehumidifying mode. If you do not use the exhaust hose in Dehumidifying mode, you must manually drain the water from the unit. Additionally, the ambient temperature in the room will probably rise by a few degrees if you do not use the exhaust hose. You will not be able to change the thermostat temperature while in Dehumidifying Mode.

EdgeStar Portable Air Conditioner

12

Image 15
Contents AP12005ECO Electrical Safety Important Safety InformationTable of Contents For Your Records IntroductionFront View Back View Parts IdentificationInstalling the Carbon Filter Preparations for installing the window kit Window Kit Installation InstructionsInstalling the grated adapter Installing the window plates Attaching the duct connectors to the exhaust hose Connecting the duct connector to the grated adapter Connecting the duct connector to the unitDirect drainage Draining the UnitButton Function Remote Control OverviewIndicators Remote Control LCD IndicatorsDehumidifying Mode Operating the Remote ControlPower Cooling ModeClock Fan Only ModeAutomatic Mode Fan SpeedFront Panel Controls TimerFront Panel Lights and Controls Front Panel LightsEnergy Saving Guide Preparation for Storage MaintenanceCleaning the unit Cleaning the pre-filterIssue Possible Cause Solution TroubleshootingTroubleshooting Specifications One 1 Year Parts & Ninety 90 Days Labor EdgeStar Limited Warranty