Timer

NOTE: To cancel the timer,

press Power button or set it at “00”.

The timer can be used to either turn the unit on or off after a number of elapsed hours. The timer is adjustable between 1-24 hours in one hour increments.

How to set the unit to automatically turn on:

1)Press the Timer button while the unit and remote are powered

off. The On Timer [] indicator will be selected and the timed hour indicator will be blinking.

2)Use the Up and Down buttons to set the number of hours you want to pass before the unit turns on.

3)Press the Timer button again to set the timer. The timed hour indicator will stop blinking. After the selected time passes, the unit will automatically turn on.

How to set the unit to automatically turn off:

1)Press the Timer button while the unit and remote are powered

on. The Off Timer [] indicator will be selected and the timed hour indicator will be blinking.

2)Use the Up and Down buttons to set the number of hours.

3)Press the Timer button again to set the timer. The timed hour indicator will stop blinking. The unit will automatically turn off after the selected time elapses.

 

Front Panel Lights and Controls

Front Panel Lights

Your portable air conditioner has a front panel that lights up different

 

colors depending on the mode it is running.

 

Cooling mode will display a blue light.

 

Dehumidify mode will display a yellow light.

 

Fan mode will display a green light.

 

Heating mode (on some models) will display a red light.

 

Automatic mode will display the color of the current mode.

 

If the unit flashes a red light and the unit stops cooling, this indicates that

 

the internal water reservoir is full. Place a pan under the unit, and remove

 

the drain plug to drain the unit.

 

If the lights flash from left to right and the unit does not work, contact

 

customer service.

 

 

 

 

Front Panel Controls

 

The front panel has an emergency power switch. The power switch

 

 

 

can be used when the unit needs to be shut off or turned on without

 

the remote control.

 

 

You can turn off the front panel lights by hitting the Lamp Off switch.

 

 

 

 

EdgeStar Portable Air Conditioner

14

Image 17
Contents AP12005ECO Electrical Safety Important Safety InformationTable of Contents For Your Records IntroductionFront View Back View Parts IdentificationInstalling the Carbon Filter Preparations for installing the window kit Window Kit Installation InstructionsInstalling the grated adapter Installing the window plates Attaching the duct connectors to the exhaust hose Connecting the duct connector to the grated adapter Connecting the duct connector to the unitDirect drainage Draining the UnitButton Function Remote Control OverviewIndicators Remote Control LCD IndicatorsPower Operating the Remote ControlCooling Mode Dehumidifying ModeAutomatic Mode Fan Only ModeFan Speed ClockFront Panel Lights and Controls TimerFront Panel Lights Front Panel ControlsEnergy Saving Guide Cleaning the unit MaintenanceCleaning the pre-filter Preparation for StorageIssue Possible Cause Solution TroubleshootingTroubleshooting Specifications One 1 Year Parts & Ninety 90 Days Labor EdgeStar Limited Warranty