INSTALLLATION PRECAUTIONS

AIR FOR COMBUSTION

Do not install burner in room with insufficient air for combustion. Be sure there is an adequate air supply for combustion if the boiler room is enclosed. It may be necessary to create a window to permit sufficient air to enter the boiler room. The installer must follow local ordinances in this regard.

CANADA It is suggested that the installer follow CSA standard B139.

USA It is suggested that the installer follow NFPA manual #31.

CHIMNEY

Be sure chimney is sufficient to handle the exhaust gases. It is recommended that only the burner be con- nected to the chimney. Be sure that it is clean and clear of obstructions.

OIL FILTER

An external oil filter is REQUIRED, even though there is an internal strainer in the pump. The filter should be replaced at least once a year, and the filter container should be thoroughly cleaned prior to installing a new filter cartridge.

DRAFT

Follow the instructions furnished with the heating appliance. The pressure in the combustion area should be kept as close to zero as possible. The burner will operate with a slight draft or pressure in the chamber.

ELECTRICAL CONNECTIONS

CANADA All electrical connections should be done in accordance with the C.E.C. Part 1, and all local codes. The system should be grounded.

USA All electrical connections should be done in accordance with the National Electrical Code, and all local ordinances. The system should be grounded.

CONTROL BURNER OPERATION

Check out the burner and explain its operation to the homeowner. Be sure to leave the Owner’s Instruction sheet with the homeowner.

FIRE EXTINGUISHER

If required by local codes, install an approved fire extinguisher.

ELECTRICAL CONNECTIONS

In most localities, a number 14 wire should be used inside a metal conduit. The system should be grounded. A service switch should be placed close to the burner on a fireproof wall in an easily accessible location.

3398

Image 2
Contents Riello 40 BF Installlation Precautions AIR for CombustionTable of Contents Package Contents List Serial Number IdentificationBurner Components Identification Technical Data SpecificationsBurner and Mounting Flange Dimensions Burner ComponentsMounting the Burner to the Boiler Electrical ConnectionsApplication Field Wiring Remote Sensing of Safety LockoutNozzle Placement INSTALLATION/REMOVAL of Drawer AssemblyElectrode Setting Turbulator SettingSingle Line SYSTEM-PIPE Lengths OIL Line ConnectionsSingle Line Gravity Feed System Line Lift SYSTEM-PIPE Lengths TWO Line Lift System Accessory package requiredNptf NPT pipe adapter TWO Line Lift System Setting the AIR Adjustment PlatePump Purge Riello Burner SET UP Sheet ~ 5sec Burner START-UP Cycle~ 12sec 2min Trouble Shooting Chart 120 Vac No VoltageTypical Layout for BF Burner Intake AIR This Intake AIR Layout for Chimney Applications onlyExploded Spare Parts List BF5 Spare Parts ListBF3 BF3 BF5Burner START- UP Form Burner Start-up Info OILTechnical Support Hotline Riello

800061000-Brn-PO Rie BF5, 800060000-Brn-PO Rie BF5, 800062000-Brn-PO Rie BF5 specifications

The Weil-McLain 800060000-Brn-PO Rie BF5, 800062000-Brn-PO Rie BF5, and 800061000-Brn-PO Rie BF5 are part of the manufacturer’s premier line of residential and commercial heating solutions. Renowned for their durability, efficiency, and advanced engineering, these models are designed to meet the diverse heating demands of modern buildings.

One of the standout features of the Weil-McLain Rie BF5 series is their robust construction. These boilers are typically built with high-grade cast iron, which not only enhances their longevity but also ensures superior heat retention. This design allows the boilers to operate efficiently over extended periods, minimizing the need for repairs and replacements.

Efficiency is a critical factor in today’s heating systems, and the Weil-McLain BF5 series excels in this category. With energy-efficient ratings, they are designed to reduce energy consumption while maintaining optimal performance. This leads to lower utility bills for homeowners and businesses alike, contributing to overall cost savings.

The technology integrated into the Rie BF5 series also plays a pivotal role in their operation. Advanced combustion technology ensures clean, efficient burning of fuel. This results in lower emissions, making these units a more environmentally friendly choice. Additionally, the incorporation of modulating gas valves allows for precise control of the heating output, enhancing comfort levels while reducing energy wastage.

Another notable characteristic is the versatility of the BF5 series. They come in various output capacities, making them suitable for a wide range of heating applications, from small residential spaces to larger commercial environments. The compact design also facilitates easier installation, making it simpler for contractors to integrate them into existing systems.

Moreover, the Weil-McLain Rie BF5 series is equipped with user-friendly controls that provide homeowners and facility managers with the ability to monitor and adjust settings as needed. This feature not only enhances user convenience but also contributes to overall performance optimization.

In conclusion, the Weil-McLain 800060000-Brn-PO Rie BF5, 800062000-Brn-PO Rie BF5, and 800061000-Brn-PO Rie BF5 embody advanced heating technology, exceptional efficiency, and durable construction. These characteristics make them an excellent choice for those seeking reliable heating solutions that stand the test of time while being environmentally conscious. Whether for residential or commercial use, these boilers deliver consistent performance and comfort, making them a trusted option in the industry.