Weil-McLain 800062000-Brn-PO Rie BF5 manual OIL Line Connections, Single Line Gravity Feed System

Page 9

GB

OIL LINE CONNECTIONS

This burner is shipped with the oil pump set to operate on a single line system.

To operate on a two-linesystem the by-pass plug must be installed.

WARNING

Do not operate a single line system with the by-pass plug installed.

Operating a single line system with the by-pass plug installed will result in damage to the pump shaft seal.

NOTE:

Pump pressure must be set at time of burner start-up.

A pressure gauge is attached to the PRESSURE PORT (8) for pressure readings.

All pump port threads are Brit- ish Parallel Thread design.

Di rect co nn ectio n of NP T threads to the pump will dam- age the pump body.

Riello manometers and vacuum gauges do not require any adapters, and can be safely connected to the pump ports.

An NPT (metric) adapter must be used when connecting other gauge models.

1

2

8

7 D7521

4

SINGLE LINE (GRAVITY FEED SYSTEM)

The burner is shipped configured for use in single line applications.

No changes to the oil pump are required for use in single line applications.

NOTE:

If the pump cover (1) is removed for any reason, be sure the O-ring (2), is properly seated in the pump cover (1) before re-attaching the pump cover to the pump housing.

Install the required fitting NPTF to NPT adapter into the pump's SUCTION LINE CONNECTION FITTING on left side of burner on top.

Attach the required tubing to this fitting. Be sure that the plug in the RETURN LINE CONNECTION FITTING is tightened securely.

SINGLE LINE SYSTEM-PIPE LENGTHS

 

H

3/8” OD

1/2” OD

 

 

 

 

 

 

 

FT

 

M

FT

M

FT

M

 

 

 

 

 

 

 

1.5

 

0.5

33

10

65

20

 

 

 

 

 

 

 

3.0

 

1.0

65

20

130

40

 

 

 

 

 

 

 

5.0

 

1.5

130

40

260

80

 

 

 

 

 

 

 

6.5

 

2.0

195

60

325

100

 

 

 

 

 

 

 

ATTENTION:

do not exceed pipe lengths indicated in chart!

P

H

D7523

3398

6

Image 9
Contents Riello 40 BF AIR for Combustion Installlation PrecautionsTable of Contents Serial Number Identification Package Contents ListBurner and Mounting Flange Dimensions Technical Data SpecificationsBurner Components Identification Burner ComponentsElectrical Connections Mounting the Burner to the BoilerRemote Sensing of Safety Lockout Application Field WiringElectrode Setting INSTALLATION/REMOVAL of Drawer AssemblyNozzle Placement Turbulator SettingOIL Line Connections Single Line Gravity Feed SystemSingle Line SYSTEM-PIPE Lengths TWO Line Lift System Accessory package required Nptf NPT pipe adapterLine Lift SYSTEM-PIPE Lengths Setting the AIR Adjustment Plate Pump PurgeTWO Line Lift System Riello Burner SET UP Sheet Burner START-UP Cycle ~ 12sec 2min~ 5sec 120 Vac No Voltage Trouble Shooting ChartThis Intake AIR Layout for Chimney Applications only Typical Layout for BF Burner Intake AIRExploded Spare Parts List BF3 Spare Parts ListBF5 BF3 BF5Burner Start-up Info OIL Burner START- UP FormTechnical Support Hotline Riello

800061000-Brn-PO Rie BF5, 800060000-Brn-PO Rie BF5, 800062000-Brn-PO Rie BF5 specifications

The Weil-McLain 800060000-Brn-PO Rie BF5, 800062000-Brn-PO Rie BF5, and 800061000-Brn-PO Rie BF5 are part of the manufacturer’s premier line of residential and commercial heating solutions. Renowned for their durability, efficiency, and advanced engineering, these models are designed to meet the diverse heating demands of modern buildings.

One of the standout features of the Weil-McLain Rie BF5 series is their robust construction. These boilers are typically built with high-grade cast iron, which not only enhances their longevity but also ensures superior heat retention. This design allows the boilers to operate efficiently over extended periods, minimizing the need for repairs and replacements.

Efficiency is a critical factor in today’s heating systems, and the Weil-McLain BF5 series excels in this category. With energy-efficient ratings, they are designed to reduce energy consumption while maintaining optimal performance. This leads to lower utility bills for homeowners and businesses alike, contributing to overall cost savings.

The technology integrated into the Rie BF5 series also plays a pivotal role in their operation. Advanced combustion technology ensures clean, efficient burning of fuel. This results in lower emissions, making these units a more environmentally friendly choice. Additionally, the incorporation of modulating gas valves allows for precise control of the heating output, enhancing comfort levels while reducing energy wastage.

Another notable characteristic is the versatility of the BF5 series. They come in various output capacities, making them suitable for a wide range of heating applications, from small residential spaces to larger commercial environments. The compact design also facilitates easier installation, making it simpler for contractors to integrate them into existing systems.

Moreover, the Weil-McLain Rie BF5 series is equipped with user-friendly controls that provide homeowners and facility managers with the ability to monitor and adjust settings as needed. This feature not only enhances user convenience but also contributes to overall performance optimization.

In conclusion, the Weil-McLain 800060000-Brn-PO Rie BF5, 800062000-Brn-PO Rie BF5, and 800061000-Brn-PO Rie BF5 embody advanced heating technology, exceptional efficiency, and durable construction. These characteristics make them an excellent choice for those seeking reliable heating solutions that stand the test of time while being environmentally conscious. Whether for residential or commercial use, these boilers deliver consistent performance and comfort, making them a trusted option in the industry.