Heatiator IDV4833IT After Fireplace is Lit, Flame Adjustment Control, Frequently Asked Questions

Page 12

I. After Fireplace is Lit

Initial Break-in Procedure

The fireplace should be run three to four hours continuously on high.

Turn the fireplace off and allow it to completely cool.

Remove fixed glass assembly. See Section 15.J.

Clean fixed glass assembly. See Section 3.

Replace the fixed glass assembly and run continuously on high an additional 12 hours.

This cures the materials used to manufacture the fire- place.

NOTICE! Open windows for air circulation during fireplace break-in.

Some people may be sensitive to smoke and odors.

Smoke detectors may activate.

Indicator

LO HI

Figure 2.4 DEXEN Valve - IntelliFire Ignition System

J. Flame Adjustment Control

Some appliances come equipped with a high/low flame adjustment control.

Open control access panel

Compare your valve to Figures 2.4 & 2.5.

Adjust the flame by turning knob as indicated in the photo matching your valve.

Indicator

HI LO

Figure 2.5 SIT Valve - Standing Pilot Ignition System

K. Frequently Asked Questions

ISSUE

SOLUTIONS

Condensation on the glass

This is a result of gas combustion and temperature variations. As the appliance warms, this

 

condensation will disappear.

 

 

Blue flames

This is a result of normal operation and the flames will begin to yellow as the appliance is allowed

 

to burn for 20 to 40 minutes.

 

 

Odor from appliance

When first operated, this appliance may release an odor for the first several hours. This is caused

 

by the curing of materials from manufacturing. Odor may also be released from finishing materials

 

and adhesives used near the appliance. These circumstances may require additional curing

 

related to the installation environment.

 

 

Film on the glass

This is a normal result of the curing process of the paint and logs. Glass should be cleaned within

 

3 to 4 hours of initial burning. A non-abrasive cleaner such as gas appliance glass cleaner may be

 

necessary. See your dealer.

 

 

Metallic noise

Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the

 

sound produced by a furnace or heating duct. This noise does not affect the operation or longevity

 

of the appliance.

 

 

Is it normal to see the pilot

In an IntelliFire ignition system (IPI), the pilot flame should turn off when appliance is turned off.

flame burn continually?

Some optional control systems available with IPI models may allow pilot flame to remain lit. In a

 

standing pilot system the pilot will always stay on.

12

Heatilator • ICON DV-IDV Series • 4042-575 • Rev. S • 5/11

Image 12
Contents Installation and Operation IDV6247IH, IDV6247ILHCongratulations Homeowner Reference InformationTable of Contents Troubleshooting Limited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Gas Fireplace Safety Operating InstructionsYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesClear Space Decorative Doors and Fronts H. Lighting Instructions IPI Final inspection byFlame Adjustment Control Frequently Asked QuestionsInitial Break-in Procedure After Fireplace is LitMaintenance and Service Maintenance Tasks-HomeownerMaintenance Tasks-Qualified Service Technician Getting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Framing and Clearances Select Appliance LocationConstruct the Appliance Chase ClearancesMantel and Wall Projections MantelsMantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesMinimum Clearances for Termination Vent Information and Diagrams Approved PipeVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal TerminationTwo 45 Elbows replacing One 90 Elbow Two ElbowsInstalled Vertically Three ElbowsInstall Flue Restrictor Top Vent Vertical TerminationNo Elbow 12 ft 3.66 m min 60 ft 18.29 m max Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Ceiling firestop Must be used between floors and at- ticsInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Secure and Level the ApplianceInstall Vent Pipe Attach Pipe to the Firebox AssemblyAssemble Vent Sections Assemble Pipe SectionsAssemble Slip Sections Secure the Vent SectionsInstall Metal Roof Flashing Disassemble Vent SectionsAssemble and Install Storm Collar 13 Assembling the Storm CollarInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap InteriorShrouds HHT ShroudsField Constructed Shrouds Open Top Shroud may be used with DVP-TV, DVP-TVHW, SLP-TVHWMailbox Style Shroud Dimensions Min. Base Dims Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Optional Accessories RequirementsIntellifire Ignition System Wiring Electrical Service and RepairJunction Box Installation Remove Two Screws From BracketFinishing Facing MaterialNon-combustible Finishing Material ModelAppliance Setup Install the Logs Base logs are pre-installed Place three top logsPlace Lava Rock and Rockwool Glass Panel Assembly Removing/Replacing Glass AssemblyEyelet Rod Support Installing External Refractories Install Side RefractoriesOpen Refractory Package Figure Bottom Front Hearth RefractoryAir Shutter Setting 24 Air Shutter AdjustmentTroubleshooting Intellifire Ignition SystemVerify that wire harness is firmly connected to the module Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP45DVP-TRAPFL DVP-TVHW DVP-TRAP DVP-HRC-SS Contact Information Do not Discard this Manual

IDV4833IT specifications

The Heatiator IDV4833IT is an innovative and efficient heating solution, ideal for homeowners seeking both aesthetics and functionality. This contemporary gas fireplace blends seamlessly with modern interior designs while offering powerful heating capabilities.

One of the standout features of the IDV4833IT is its impressive heating capacity, capable of efficiently warming spaces of up to 1,600 square feet. This makes it an excellent choice for larger rooms or open-concept living areas, ensuring consistent warmth during colder months. The fireplace is powered by natural gas or propane, providing flexibility depending on local availability and preference.

A defining characteristic of the Heatiator IDV4833IT is its advanced technology. The unit is equipped with a programmable thermostat, allowing users to set and maintain their desired temperature efficiently. This feature not only enhances comfort but also optimizes fuel consumption, making it an eco-friendly option. The fireplace also includes an easy-to-use remote control system, enabling users to adjust settings from across the room without any hassle.

The design of the IDV4833IT stands out with its sleek, linear appearance and large viewing area, framed by a minimalist façade. The expansive glass panel provides a captivating view of the flames, adding a touch of elegance to any living space. The adjustable flame height allows homeowners to customize the ambiance, creating a cozy atmosphere for gatherings or a tranquil setting for relaxation.

Additionally, the Heatiator IDV4833IT is designed with safety in mind. It features a built-in safety shut-off system that automatically turns off the gas supply in case of malfunction. The unit also includes a protective barrier to prevent accidental contact with the hot glass surface, ensuring peace of mind for families with children or pets.

In summary, the Heatiator IDV4833IT combines aesthetic appeal with advanced heating technology. Its substantial heating capacity, programmable thermostat, and user-friendly design make it an ideal choice for those seeking a reliable and stylish heating solution. Emphasizing safety and efficiency, this fireplace stands as a testament to modern home heating solutions and an investment in comfort for years to come.