Installation

SAFETY NOTICE: IF YOUR DUTCHWEST CON- VECTION HEATER IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. FOR SAFETY, FOLLOW ALL INSTALLA- TION, OPERATION AND MAINTENANCE DIREC- TIONS. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.

Before you begin the installation, review your plans to confirm that:

Your stove and chimney connector will be far enough from combustible material to meet all clearance require- ments.

The floor protector is large enough and is constructed properly to meet all requirements.

You have obtained all necessary permits from local authorities.

Your local building official is the final authority for ap- proving your installation as safe and for determining that it meets local and state codes.

Clearance and installation information is printed on the metal label attached to the rear of the stove. Local au- thorities generally will accept the label as evidence that, when the stove is installed according to the information on the label and in this manual, the installation meets codes and can be approved.

Codes vary in different areas, however. Before starting the installation, review your plans with the local building authority. Your local dealer can provide any additional information needed.

Important: Failure to follow these installation instruc- tions may result in a dangerous situation, including a chimney or house fire. Follow all instructions exactly, and do not allow makeshift compromises to endanger

property and personal safety.

Chimney Types

Your Dutchwest Convection Heater must be connected to a sound masonry chimney that meets local codes, a relined masonry chimney that meets local codes, or to an approved prefabricated metal chimney. Whatever kind you use, the chimney and chimney connector must be in good condition and kept clean.

Masonry Chimneys

If you use an existing masonry chimney, it must be inspected to ensure safe condition before the stove is installed. Your local professional chimney sweep, building inspector, or fire department official will be able either to make the inspection or to direct you to some- one who can.

An inspection of the chimney must confirm that it has a lining. Do not use an unlined chimney. The chim- ney should also be examined for cracks, loose mortar, other signs of deterioration, and blockage. Repair any defects before the chimney is used with your stove.

Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Open- ings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement. In the event of a chimney fire, flames and smoke may be forced out of these unused thimbles.

The chimney should be thoroughly cleaned before use.

A newly-built masonry chimney must conform to the standards of your local building code or, in the absence of a local code, to a recognized national code. Masonry chimneys must be lined, either with code-approved masonry or pre-cast refractory tiles, stainless steel pipe, or a code-approved, “poured-in-place” liner. The chimney’s clean-out door must seal tightly.

Prefabricated Double-Wall

Insulated Chimney

Tile Lined

Masonry

Chimney

ST241

Fig. 2 If in sound condition and approved for use, either a masonry or a prefabricated chimney may be used.

4

7001135

Image 4
Contents Convection Heater Model 2460, 2461 Accessories Table of ContentsSpecifications Stove Model Number 2460 2461 2462Chimney Types InstallationMasonry Chimneys Guidelines for Installing the Chimney Connector Two Types of ConnectorSingle-Wall Connector Prefabricated ChimneysDouble-Wall Connector Assembling Single-Wall Chimney ConnectorSecuring the Connector To a Prefabricated Chimney Toward Stove Flue Gas DirectionFreestanding Installations Securing the Connector to a Masonry ChimneyFireplace Installations Above the Fireplace Fireplace Installations Through the Fireplace Wall Pass-ThroughsFloor Protection Fireplace InstallationsModel Canada Keep the Stove a Safe Distance From Surrounding Materials Safe Ways To Reduce ClearancesFireplace Installation Clearances ModelClearance Chart Reference Diagrams Designing a Safe InstallationRear exit, rear heat shield installations Stove Clearance Chimney Connector ClearanceFront Clearance to Combustibles Chimney Connector Side Rear Corner Model 2460 Small ConvectionWall Heat Shield Dimensions Unpack the Parts AssemblyAttach the Legs and Bottom Heat Shield Heater Controls and Features Air Controls OperationDamper Function Burn Only High-Quality Fuel Load DoorsSuccessful Wood Burning OpenPrimary Air Use the Air Control Settings That Work Best for YouCatalyst Air How to Build and Maintain a Wood Fire Loading Wood Break-in FiresLighting the Fire Reloading and Reviving the FireRemove Ashes Frequently Further suggestionsSafe Ash Handling Maintenance Cleaning the GlassAdjust the Door Latch Test And Repair the Door GasketsDamper Adjustment Primary Air Control AdjustmentRepair Missing Cement in Seams Avoid Damaging the Glass Door PanelCleaning the Chimney System Inspect Regularly, Clean as RequiredMaintenance Schedule Annual Spring CleaningYearly Spring Cleaning When to Suspect a Combustor ProblemCare of the Catalytic Combustor Assess Your Present Operating ConditionsRemove and Inspect the Combustor Watch for Better ResultsCatalytic Combustor Draft Management Draft Testing Single VentingBackpuffing FuelDutchwest Convection Heater Item/DescriptionDutchwest Convection Heater Warranty