CFM Corporation 2460, 2462, 2461 manual Dutchwest Convection Heater

Page 31

Dutchwest Convection Heater

Models 2460, 2461, 2462 (continued)

 

Item/Description

2460

2461

2462

5.

Inner Top

7001112

7001119

(See Item #61)

 

Inner Top Ass’y (Inner Top, Web, Gasket, Tabs & Bolts)

0000003

0000004

0000016

 

Inner Top Ass’y (Inner Top, Web, All Hardware, Baffle,

--

7001171

--

 

All Gaskets)

 

 

 

6.

Inner Top Web

7001110

7001110

7000110 (to 7/97)

7.

Inner Top Channel Cap

7000961

7000974

7000987

8.

Air Distributor

7000952

7000952

7000952

9.

Baffle

7000953

7000953

--

10.

Right Side (After 7/97 no outside air)

7001229

7001229

7001232

11.

Left Side

7001120

7001120

7001150

12.

Side Door

7001121

7001121

7001151

13.

Load Door Handle (2)

5004245

5004245

5004245

14.

Door Pawl (2)

5004025

5004025

5004025

15.

Pawl Assembly (Load Door)

--

30002362

30002362

16.

Primary Air Manifold

7001137

7001122

7001152

17.

Front

7001139

7001124

7001154

18.

Gasket for Front Door

7000910

7000910

7000910

19.

Ashdoor

7001141

7001126

7001156

20.

Grate

30002092

30002092

7001148

21.

Retainer Tab for Web (2)

1601488

1601488

1601488

22.

Fan Plate

7000037

7000037

7000037

23.

Damper

7000954

7000954

7000954

24.

Damper Adjuster

7000950

7000950

7000950

28.

Damper Tab (2)

1601488

1601488

1601488

29.

Damper Crank

7000951

7000951

7000951

30.

Damper Operating Rod

7001145

7001131

7001160

31.

Grate Back

7001166

7001166

7001178

32.

Top

7000960

7000972

7000985

33.

Hearth

7001142

7001127

7001157

34.

Flue Collar

7000969

7000969

1304280

35.

Leg

7000016

7000016

7000016

36.

Damper Handle Stub

5004265

5004265

5004265

37.

Ash Door Handle

5004237

5004237

5004237

38.

Ash Pan

7000G79

7000G69

7000G89

39.

Gasket for Glass

1203591

1203591

1203591

40.

Glass

7001146

7001132

7001161

41.

Manifold Cap (2)

7001163

7001164

7001165

42.

Holder for Door Handle Insert

1600600

1600600

1600600

43.

Primary Air Control

30002738

30002739

30002737

44.

Damper Tab for Primary Control

1601488

1601488

1601488

45.

Spring for Primary Control

1201846

1201846

1201846

47.

Front Door

7001140

7001125

7001155

48.

Inner Bottom Screw, 1/4-20 x 3³⁄₄

1201394

1201394

1201394

50.

Andiron (2)

7001117

7001117

7001117

53.

Side Wear Plate

7001198

7001198

7001199

54.

Interam Gasket

0000837

0000837

0000837

55.

Catalytic Combustor

000CB56

000CB56

000CB56

56.

Refractory

1602515

1602515

1602515 (to 7/97)

57.

Combustor Air Inlet

7001128

7001128

7001128

58.

Probe Thermometer

7000948

7000948

7000948

59.

Brass Bar

30002731

30002732

30002733

60.

Refractory Package1 (as of 7/97)

--

--

1602514

61.

Inner Top1

--

--

7001226

62.

Inner Top Insert/Baffle Combination as of 1/972

--

--

7001225

63.

Wood Handle w/Lifter - NI

30002787

30002787

30002787

64.

Bottom Heat Shield Kit (not shown)

0001074

0001075

0001076

1On Extra-Large units built after August 1997, Refractory differs from Small & Large units.

2On Extra-Large units built after August 1997, Inner Top and Insert differ from pre-August 1997 units.

7001135

31

Image 31
Contents Convection Heater Model 2460, 2461 Table of Contents AccessoriesStove Model Number 2460 2461 2462 SpecificationsChimney Types InstallationMasonry Chimneys Prefabricated Chimneys Guidelines for Installing the Chimney ConnectorTwo Types of Connector Single-Wall ConnectorToward Stove Flue Gas Direction Double-Wall ConnectorAssembling Single-Wall Chimney Connector Securing the Connector To a Prefabricated ChimneyFreestanding Installations Securing the Connector to a Masonry ChimneyFireplace Installations Above the Fireplace Wall Pass-Throughs Fireplace Installations Through the FireplaceFloor Protection Fireplace InstallationsModel Canada Safe Ways To Reduce Clearances Keep the Stove a Safe Distance From Surrounding MaterialsModel Fireplace Installation ClearancesClearance Chart Reference Diagrams Designing a Safe InstallationRear exit, rear heat shield installations Stove Clearance Chimney Connector ClearanceFront Clearance to Combustibles Side Rear Corner Model 2460 Small Convection Chimney ConnectorWall Heat Shield Dimensions Unpack the Parts AssemblyAttach the Legs and Bottom Heat Shield Operation Heater Controls and Features Air ControlsOpen Damper Function Burn Only High-Quality FuelLoad Doors Successful Wood BurningPrimary Air Use the Air Control Settings That Work Best for YouCatalyst Air Reloading and Reviving the Fire How to Build and Maintain a Wood Fire Loading WoodBreak-in Fires Lighting the FireRemove Ashes Frequently Further suggestionsSafe Ash Handling Test And Repair the Door Gaskets MaintenanceCleaning the Glass Adjust the Door LatchAvoid Damaging the Glass Door Panel Damper AdjustmentPrimary Air Control Adjustment Repair Missing Cement in SeamsAnnual Spring Cleaning Cleaning the Chimney SystemInspect Regularly, Clean as Required Maintenance ScheduleAssess Your Present Operating Conditions Yearly Spring CleaningWhen to Suspect a Combustor Problem Care of the Catalytic CombustorWatch for Better Results Remove and Inspect the CombustorCatalytic Combustor Draft Management Fuel Draft TestingSingle Venting BackpuffingItem/Description Dutchwest Convection HeaterDutchwest Convection Heater Warranty